• Title/Summary/Keyword: Normal tension

Search Result 355, Processing Time 0.119 seconds

Changes of Surface Temperature and Electromyography Activities by Local Heat and Cold (온열과 냉의 국소적용에 의한 체표면 온도와 근전도 활동의 변화)

  • Choi, Seok-Ju;Lim, Sang-Wan;Kim, Su-Hyon;Mun, Dal-Ju
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.61-72
    • /
    • 2007
  • INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in $45^{\circ}$ flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level $\alpha$ was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=88.930, P<0.001). Changes of surface temperature of vastus medialis muscle according to heat application were radically increased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=27.267, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=19.774, P<0.001). Changes of sEMG by heat and cold application were no statistical difference. Surface temperature of skeletal muscle after heat and cold application showed significant change for 30 min., but it was found that increase or decrease of surface temperature had not great influence on sEMG activities.

  • PDF

OCCLUSAL FORCE AND EMG CHANGE OF MANDIBULAR FRACTURE (악골 골절에서 술 후 교합압 및 근전도 변화)

  • Choi, Yong-Kwan;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.293-299
    • /
    • 2008
  • Bite force is created by the force of adjacent teeth accompanied with tension of masticatory muscle. The bite force value is greater in male than in female and ha maximum value at first molar. Masseter muscle is associated with bite force and during muscle contraction the electric signal is expressed in EMG form. The aim of the study is to assess recovery time for masseter muscle activity and according to each part of bite force after open reduction with internal fixation when mandibular angle fracture and subcondyle fracture occurred. And to determine the appropriate period for mandibular fracture patients to have normal masticatory activity. 30 patients with normal bite condition was selected for control group and from April, 2007 to September, 2007, 20 patients who visited our department of oral and maxillofacial surgery of Dankook University, were selected for the study and were diagnosed as mandibular angle fracture and subcondyle fracture. For control group, the bite force for incisors, canine, premolars and molars and activity of the masseter muscle was measured and compared for 1, 2, 3, 4, 6 and 8 weeks. That was divided as fracture side and normal side. Mann-Whitney U test was performed for significant difference and the following result was obtained. 1. The maximum voluntary bite force for incisors, canine, premolars and molars portion were 0.113 kN, 0.182kN, 0.295kN and 0.486kN and the masseter muscle activity was 0.192 volts in the control group. 2. The maximum bite force at fracture side was recovered by 4th weeks for incisors, 6th weeks for canine and premolars and 8th weeks for molars and the masseter muscle activity was recovered by 6th weeks in the experimental group. 2. The maximum bite force at normal side was recovered by 4th weeks for incisors, 6th weeks for canine, premolars and molars and the masseter muscle activity was recovered by 3rd weeks in the experimental group. 3. The method for internal fixation by 2.0mm miniplates at both superior and inferior border had no complications according for twenty patients and had a satisfactory recovery. According to the result, patient with mandibular angle fracture and subcondyle fracture, 8 weeks was required for bite force recovery. Therefore, patients with open reduction and internal fixation under general anesthesis, it can be assumed that 8 weeks was needed after operation in order to have normal bite force and masseter muscle recovery.

Interfacial properties of composite shotcrete containing sprayed waterproofing membrane

  • Park, Byungkwan;Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Kim, Jintae;Choi, Myung-Sik;Jeon, Seokwon;Chang, Soo-Ho
    • Geomechanics and Engineering
    • /
    • v.16 no.4
    • /
    • pp.385-397
    • /
    • 2018
  • This study evaluates the interfacial properties of composite specimens consisting of shotcrete and sprayed waterproofing membrane. Two different membrane prototypes were first produced and tested for their waterproofing ability. Then composite specimens were prepared and their interfacial properties assessed in direct shear and uniaxial compression tests. The direct shear test showed the peak shear strength and shear stiffness of the composites' interface decreased as the membrane layer became thicker. The shear stiffness, a key input parameter for numerical analysis, was estimated to be 0.32-1.74 GPa/m. Shear stress transfer at the interface between the shotcrete and membrane clearly emerged when measuring peak shear strengths (1-3 MPa) under given normal stress conditions of 0.3-1.5 MPa. The failure mechanism was predominantly shear failure at the interface in most composite specimens, and shear failure in the membranes. The uniaxial compression test yielded normal stiffness values for the composite specimens of 5-24 GPa/m. The composite specimens appeared to fail by the compressive force forming transverse tension cracks, mainly around the shotcrete surface perpendicular to the membrane layer. Even though the composite specimens had strength and stiffness values sufficient for shear stress transfer at the interfaces of the two shotcrete layers and the membrane, the sprayed waterproofing membrane should be as thin as possible whilst ensuring waterproofing so as to obtain higher strength and stiffness at the interface.

Experiments on Interfacial Properties Between Ground and Shotcrete Lining (지반과 숏크리트 라이닝의 인터페이스 특성에 관한 실험적 연구)

  • 장수호;이석원;배규진;최순욱;박해균;김재권
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.79-86
    • /
    • 2004
  • Interfacial properties between rock mass and shotcrete play a significant role in the transmission of loads from the ground to shotcrete. These properties have a major effect on the behaviours of rock mass and shotcrete. They, however, have merely been considered in most of numerical analyses, and little care has been taken in identifying them. This paper aimed to identify interfacial properties including cohesion, tension, friction angle, shear stiffness, and normal stiffness, through direct shear tests as well as interface normal compression tests for shotcrete/rock cores obtained from a tunnel sidewall. Mechanical properties such as compressive strength and elastic modulus were also measured to compare them with the time-dependent variation of interfacial properties. Based on the experiments, interfacial properties between rock and shotcrete showed a significant time-dependent variation similar to those of its mechanical properties. In addition, the time-dependent behaviours of interfacial properties could be well regressed through exponential and logarithmic functions of time.

Buccinator Myomucosal Flap for Wide Cleft Palate (넓은 입천장갈림증에서 협근 근점막피판을 이용한 입천장성형술)

  • Nam, Seung Min;Tark, Min Seong;Kim, Cheol Han;Park, Eun Soo;Kang, Sang Gue;Kim, Young Bae
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.748-752
    • /
    • 2007
  • Purpose: The goal of palatoplasty is focused on two points. One is to close the palatal defect completely, and the other to create a velopharyngeal system for normal speech. While established methods such as pushback palatoplasty or double opposing Z palatoplasty are used in wide cleft palate repair, sequelae such as maxillary hypoplasia or oronasal fistula may result. Therefore, when palatoplasty with buccinator myomucosal flap is used in the case of wide cleft palates, maxillary hypoplasia and oronasal fistula is reduced and optimal results are obtained. Methods: From October 2005 to December 2006, four children with wide complete cleft palate underwent unilateral buccinator myomucosal flap and intravelar veloplaty. Mean age at cleft repair was 15 months, and mean cleft size was 2.15 cm. The patients underwent intravelar veloplasty and palatoplasty was done using unilateral buccinator myomucosal flap. Results: The patients, after mean 10 months of follow-up observation, showed no signs of oronasal fistula resulting from flap tension. The shape and color similar to normal oral mucosa was obtained, and velopharyngeal function was acquired. Conclusion: When intravelar veloplasty and palatoplasty with unilateral buccinator myomucosal flap is done on wide cleft palates, postoperative speech function is optimal, velopharyngeal incompetence is effectively corrected, and sequelae resulting from pushback palatoplasty and double opposing Z-plasty, such as maxillary hypoplasia and oronasal fistula, is reduced.

A Study on the Pulmonary Hemodynamic Changes before and after PEEP in ARDS (호흡부전증에세 호기말 양압호흡법 치료 전후의 폐혈류역학적 변화에 관한 연구)

  • Chung, June-Key;Shin, Seong-Hae;Khang, Shin-Kwang;Park, Sung-Ki;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Kim, Yong-Lack;Kim, Kwang-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.18 no.1
    • /
    • pp.45-53
    • /
    • 1984
  • The purpose of this study is to observe the changes of pulmonary capillary permeability and various hemodynamic parameters before and after Positive End-Expiratory Pressure(PEEP) in Adult Respiratory Distress Syndrome (ARDS). Using a canine oleic acid induced ARDS model, we measured the pulmonary capillary permeability with a slope of lung: heart radioactivity ratio, hemodynamic parameters with Swan-Ganz catheter and blood gas tensions. 1) In normal and ARDS dogs, the PEEP didn't significantly influence the slope of lung: heart radioactivity ratio. But in ARDS group the slope index was increased compaired with that of control group (p<0.05). 2) Also in ARDS group, $PaO_2$ was significantly decreased, and $PaCO_2,\;PvCO_2$, MPAP, $AaDO_2$, Qs/Qt were significantly increased compared with those of control group (p<0.05). 3) In normal dogs, the PEEP didn't influence blood pH or gas tension, $AaDO_2$, Qs/Qt, or hemodynamics. 4) In ARDS dogs, however, the PEEP significantly increased $PaO_2$ and decreased $AaDO_2$, Qs/Qt (p<0.05).

  • PDF

CLINICAL AND RADIOLOGICAL COMPARISON BETWEEN TITANIUM AND BIODEGRADABLE MINIPLATE MONOCORTICAL OSTEOSYNTHESIS IN MANDIBULAR ANGLE FRACTURES (Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구)

  • Choi, Eun-Joo;Nam, Woong;Jung, Young-Soo;Kim, Ki-Ho;Kim, Hyung-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.3
    • /
    • pp.222-225
    • /
    • 2006
  • The treatment objective of mandibular fracture is a return to normal function. According to Champy, a rigid fixation of mandibular angle fracture is performed by using 4 or 6 holes titanium miniplates on the external oblique ridge of mandible. However, the limitations of metal plate such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy due to the lack of normal stress reaction of the bone have been reported. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite its lower strength than that of the titanium plate and the side effect caused by the resorption in the body. In this study, 61 patients diagnosed as mandibular angle fracture and treated from Jan. 1998 to Dec. 2004 in our department have been reviewed. Metal plate fixation was used in 50 patients and biodegradable plate fixation in 11 patients on the external oblique ridge around the fractured mandibular angle according to the principle of monocortical osteosynthesis by Champy. We compared the incidence of side effects and the degree of bony union at the mandibular inferior border in two different fixation methods. In conclusion, we have found that one miniplate regardless of matter could provide enough strength to grasp bony fragments of the tension site and compress the inferior border of mandible without any complications.

A Study on the Structural Reliability (구조물(構造物)의 신뢰성(信賴性)에 관한 소고(小考) -원형단면의 인장재를 중심으로-)

  • Son, Seung Yo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 1985
  • In the design of civil engineering structures, the designers are invariably faced to the uncertainties and the randomness of the design parameters such as material properties and loads. Even when the structures are built, the actual geometries of the structures are also subject to their random variations from their nominal design values. Thus, the reliability of a structure in terms of these uncertainties and variations becomes a matter of great concern to the structural designers. This study employs the First Order Second Moment Method to evluate numerically the reliability of a simple tension member and discusses the influence on the final failure probability of that structure due to: 1) use of equivalent normal distribution in place of non-normal distribution, 2) linearization of non linear limit state equation. A discussion is also made on the necessity of fundamental studies on the distrubution characteristics of the strength of locally produced construction materials and those of the loads frequently encountered in the structural design.

  • PDF

Redo-left Ventricular Volume Reduction Surgery in a Patient with Left Ventricular Aneurysm -1 case- (급성 심근경색 후 좌심실류절제술을 받은 환자에서 재 좌심실용적감소술의 시행)

  • Lee Sak;Lee Chang Young;Lee Kyo Jun;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.1 s.246
    • /
    • pp.63-66
    • /
    • 2005
  • Surgical anterior ventricular endocardial restoration (SAVER) is a technique that improves hemodynamic status by excluding akinetic or dyskinetic portions of the left ventricle, restores the ventricle to normal elliptical shape and reduces ventricular wall tension to normal level in patients with acute anterior wall myocardial infarction that accompanies aneurysm. We performed redo-SAVER procedure in a 40-year old man with remodeled dilated ventricle who had already underwent LV aneurysmectomy 12 years earlier, and the results were satisfactory.

Stress Analysis and Lead Pin Shape Design in PGA (Pin Grid Array) Package (PGA (Pin Grid Array) 패키지의 응력해석 및 Lead Pin 형상설계)

  • Cho, Seung-Hyun;Choi, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.29-33
    • /
    • 2011
  • Research about the geometry design of lead pin was carried based on the normal or shear stress of the interface between a lead pin and a PCB in terms of delamination failure. The taguchi method with four design factors of three levels and FEA(Finite element Analysis) are carried under $20^{\circ}$ bending and 50 ${\mu}m$ tension of lead pin. The contact width, d2, between head round and copper pad in PCB is the highest affection factor among design factors by analysis of contribution analysis. Equivalent von Mises stress of 18.7% reduction design is obtained by the parameter design of the taguchi method. Maximum normal stress occurred at contact position between solder outer surface and a Cu pad in PCB. Also, maximum shear stress happened at contact position between solder outer surface and SR layer of PCB. From these calculated results, delamination of the PGA package may be occurred from outer interface of solder to inner interface of solder.