• Title/Summary/Keyword: Normal direction

검색결과 1,131건 처리시간 0.036초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

치주인대 신장에 의한 치아의 급속 견인 시 성견 치주조직의 변화 (Histological Periodontal Tissue Reaction to Rapid Tooth Movement by periodontal Distraction in Dogs)

  • 장영일;김태우;최희영
    • 대한치과교정학회지
    • /
    • 제32권6호
    • /
    • pp.455-466
    • /
    • 2002
  • 본 연구의 목적은 periodontal distraction을 통해 급속 견인된 치아의 치조골과 치주인대에서 일어나는 변화를 조직학적으로 관찰하고, 치주조직이 정상적으로 재생될 수 있는지를 규명하는 것이다. 4 마리의 성견을 대상으로 하여, 좌우 상악 제2소구치를 발치 후에 상악 제1소구치 원심측 치간골에 홈을 주는 치조골 수술을 통해 골 저항을 약화시키고 제1소구치와 제3소구치에 periodontal distraction 장치를 장착하였다. 장치는 0.225mm씩, 하루에 2회 활성화시키며 상악 제1소구치를 발치와 공간으로 급속 견인하였다. 치아의 급속 견인은 5 일, 10 일, 20 일간 시행하였으며, 20 일간 견인한 대상에서는 2 주, 4 주, 8 주 후까지 유지기간을 두었다. 20 일간의 periodontal distraction을 통해 상악 제1소구치는 평균 5.02mm 원심 이동하였고, 고정원인 제3소구치는 0.58mm 근심 이동하였다. 조직학적 검사에서 distraction된 치주인대 공간에서는 골 재생과 개조가 빠르게 일어나, 견인 10일에 유골조직이 치아의 견인방향에 평행하게 생성되었고, 새로운 골 조직의 형성과 골 개조를 통한 골 성숙은 periodontal distraction 방향을 따라 활발히 진행되었으며, 이는 다른 골의 distraction osteogenesis에서 나타나는 결과와 비슷하였다. 급속 견인된 치아의 치주인대는 상당히 넓게 나타났고, 교원섬유와 치아간의 정상 관계는 급속 견인이 끝난 후 2주에 나타나기 시작하여 8주에 거의 회복되었다. 그러나, 치주인대의 골 쪽에서는 치아 급속 견인 후 8주까지도 새로운 골이 계속 형성되고 있었고, 교원섬유속이나 Sharpey 섬유는 보이지 않았다. 고정원으로 이용된 치아 주위의 조직반응은 통상적인 교정치료에서와 같이 압박 측에서의 골 흡수와 신장 측에서의 골 형성 소견을 나타냈다. 이상의 결과로 볼 때, periodontal distraction을 통한 치아의 급속 견인 시, 치주인대 조직은 잘 반응하여 치주조직의 재생이 활발히 일어남을 알 수 있었다.

팔봉광산 선광광미와 주변토양의 중금속 오염 특성 (The Characteristics of Heavy Metal Contamination in Tailings and Soils in the Vicinity of the Palbong Mine, Korea)

  • 이영엽;정재일;권영호
    • 자원환경지질
    • /
    • 제34권3호
    • /
    • pp.271-281
    • /
    • 2001
  • 팔봉광산 주변 지역의 오염 특성을 밝히기 위해 선광광미와 주변 토양의 중금속 오염 특성을 조사하였다. 연구 지역의 토양은 일부 토양을 제외한 대부분의 토양이 롬 토양이었으며, 하천 주변 토양 일부도 상류 지역에서 하류쪽으로 가면서 로미 샌드_샌디 롬 토양에서 롬토양으로 점이한다. 토양 내의 유기물 함량은 평균 2% 정도로 낮았으며, 토양의 pH는 모든 시료에 걸쳐 약간 산성을 띄는 6.0$\pm$0.1이다. 연구 지역에서 분석된 암석, 일반토양, 광미 및 퇴적시료에서는 암석으로부터 기인된 일반토양에서는 중금속의 함량이 암석 자체에 포함된 농도보다 약간씩 낮아져 이들이 지표수나 지하수에 의해 침출되어 나감을 보여준다. 광석으로부터 분리된 광미 더미 시료에서는 납, 구리, 비소의 농도가 높다. 하천 퇴적시료에서도 정상적인 확산 특성을 보이나, 상류 시료에서 납, 구리의 농도는 광미 더미에서 보다 훨씬 높은 농도를 보이는 한편, 비소는 그 농도가 급격하게 떨어지는 특성을 보인다. 카드뮴과 구리, 비소의 농도 변화는 운반 매체로서의 지표수 혹은 지하수의 매질 특성에 기인한 것으로 해석된다. 중금속 농도 분포와 퇴적입자 크기는 카드뮴, 구리 및 납 등은 모래 및 실트와 비교적 높은 상관관계를 보이는 반면, 비소와 수은은 점토입자와는 상관관계가 높았다. 연구 지역에서 측정된 중금속의 거리별 확산 특성은 하천 주변 토양 중 표토 및 심토층에서는 광미 더미로부터 100m~200m에 구간에서 측정된 중금속 농도가 광미 더미에서 먼 다른 지역과는 현격하게 높은 농도를 보이는 점이다. 카드뮴과 구리, 납 및 수은의 농도가 차이가 많으며, 비소는 차이가 크지 않다. 육가 크롬은 전 구간에 걸쳐 검출되지 않는다. 중금속의 농축은 광산 개발지나 광미 더미로부터 기인되어, 물에 의해 이동, 침전되었을 것이다. 하천 주변 표토 및 심토층에서는 모든 중금속 농도가 광미 더미에서 하류쪽으로 이동한 600m~2000m 구간에서 상승하였다. 광미 확산 토양 시료에서는 중금속의 농도가 광미 더미로부터 멀어질수록 비교적 일정하게 감소한다. 600~2000m 거리구간에서의 각 중금속의 농도 상승은 지하수에 의해 이동되었을 것으로 추정된다. 중금속의 유동에는 유동 지하수의 pH, Eh 및 콜로이드 입자의 양, 산화망간 및 산화철의 존재에 따른 지하수의 상태 변화가 밀접하게 연관되었을 것이다. 지하수 조건은 3 정도의 비교적 낮은 pH와 +3~+5에 해당되는 산화 조건과 콜로이드는 적고 산화망간 및 산화철이 같이 유동하지 않은 상태였다. 중금속의 유동은 과거의 광산활동과 연관되었을 것이다. 연구지역에서는 오염 토양이 식생의 중금속 오염에는 영향을 미치지 않는다.

  • PDF

직업교사 전문화 및 직업과학 학과발전에 기반한 중국 직업교육 교사양성 전망 -UNESCO '국제 직업교사 석사 교육과정 구성표준'을 중심으로- (The development direction of vocational education teachers' fostering of china based on vocational teachers specialization and vocational disciplines)

  • 유자룡;조지군;남승권;최완식
    • 대한공업교육학회지
    • /
    • 제35권2호
    • /
    • pp.70-81
    • /
    • 2010
  • 이 연구의 목적은 중국 직업교육 교사 양성에 대한 시사점을 제시하기 위해 국제 직업교사 석사 교육과정 구성표준을 소개하고 이와 관련된 내용을 분석하는데 있다. 2004년 UNESCO에서는 국제학술 교류를 촉진할 뿐 아니라 교사와 훈련지도자 등 직업교육 및 훈련 영역 전문 인원의 능력을 증진시키기 위하여 '국제 직업교사 석사 교육과정 구성 표준'을 구성하였다. 이에 따르면 교육과정 표준을 도입한 대학교는 전문 위원회를 구성하여야 하며, 다른 학교의 상황 및 학생 능력과 학력인증체제 등의 구체적 상황을 고려하여 교육을 실시하여야 한다. 교육과정 표준은 국제 직업교육과학 발전의 최신 경향을 포함하며 아울러, 한 국가 내의 여러 고등학교 간에 혹은 여러 국가의 고교 간에 연합교육 학습을 실시할 수 있도록 하였다. UNFSCO는 교육과정 표준을 통하여 직업교육 학습이론과 직업과학 등 직업교육 기초학과의 교육학습과 연구의 발전을 촉진하고자 하며 직업교육의 교사소양을 제고하고 직업교사의 전문화를 실현하고자 하였다. 중국에서 직업교육 석사과정을 설치한 대학교는 20여 개이며, 매년 모집하는 학생의 수는 2,000여 명이다. 각 대학의 직업교사 석사과정 계획을 살펴보면, 교육과정 및 교육학습과 같은 실제적 문제를 다루는 과정에 대한 설치가 미비한 실정이다. 그러나 교육과정 표준에서는 응용 이론의 교육 학습과 연구를 보다 중요시하고, 구체적 영역에 대한 실천과 교육 학습을 더욱 강조하고 있다. 교육과정 표준과 관련된 선진국의 앞선 경험을 활용하는 것이 중국 직업교사 양성모델과 학과 체계의 탐색에서 중요한 의미를 갖고 있으며, 중국 직업교사 양성과정의 전공 및 교육과정 설치에 유용한 여러 가지 점을 시사해 준다.

  • PDF

동병하치 확산을 위한 전략적 방향과 이행방안 (Strategic Direction and Road Map of Expanding Prevention of Winter Disease in the Summer)

  • 송호섭
    • Journal of Acupuncture Research
    • /
    • 제27권3호
    • /
    • pp.147-157
    • /
    • 2010
  • Objectives : The purpose of this study was to propose appropriate strategic directions and road maps for successful achievement of programs preventing winter disease in the summer. Methods : Details on programs preventing winter disease in the summer such as clear concept, theoretical basis, current status, intervention or available prescriptions and indication/contraindication/caution were prepared through the related journal review, upon which an observational study was devised and done for simulation to find out even a trivial problem and to guarantee the safety beforehand. The experimental group was divided into 5 groups by the size of pill and the way ginger is treated; 1cm pill with ginger group, 3cm pill group without ginger, 3cm pill group dipped into ginger, 3cm pill group applying ginger to acupoints and 3cm pill group with ginger Results 1. program preventing winter disease in the summer was defined as representative winter diseases such as common cold, influenza, chronic asthma, chronic bronchitis, allergic rhinitis, emphysema, chronic gastritis and rheumatoid arthritis, and preventive care in the summer, reinforcing deficient yang qi of five viscera by using exuberant yang qi from summer heat. 2. It was based upon historically established theories which is 'nourishing yang qi in the spring and summer', 'long summer, namely rainy spell in the summer overwhelms the winter, because of earth winning water according to the five phases theory' and 'To replenish yang qi is major principle to treat winter diseases, which can be most appropriately and timely applied to the patient with deficient yang qi of five viscera inherently, especially in the three dog days of the summer, because of exuberant exterior yang qi and deficient interior yang qi in the five viscera'. 3. In the adjacent China and Taiwan, acupoint applying method in the three dog days named 'San Fu Tie' have been stirring a boom throughout the nation, in which Xiaochuan Gao was used as a basic prescription and it mainly was applied at bilateral $BL_{13}$, $_{15}$ and $_{17}$ for about 4 hours. As far as domestic current status, the necessity of adopting the above method prior to Herbal formula was also recognised, because not a few koreans have apprehension for the safety of it including medicinal herbs and are reluctant to take it any more due to negative advertisement of narrow minded doctors' association. 4. Indication of acupoint applying method in the three dog days included most of winter diseases such as common cold, influenza, chronic asthma, chronic bronchitis, allergic rhinitis, emphysema, chronic gastritis. contraindication was pregnant woman and the weak such as infants and the old. More attention was paid to grasp firmly the normal reaction following the treatment for preventing side effect and teasing blister. recommendation was also given to abstain from food inducing phlegm and dampness such as meat, shrimp and crab as well as cold drinks and foods 5. In the simulation observational study based upon the above findings following review the related articles, no blister was shown on the acupoints icluding bilateral $BL_{13}$, $_{15}$ and $_{17}$ in every experimental group during 24hr observation following the acupoint applying treatment with pills made by modified and devised prescription. At 4 hr, the effectiveness of it reached a peak showing redness and mild tenderness and there is little difference between groups 3cm pills groups regardless of the way ginger was treated. abdominal distention and growling was found in all the volunteers during the treatment at CV 8. Strategic directions and road maps : Through successful fulfillment of the program preventing winter disease in the summer, Korean traditional medicine should be integrated into mainstream national health care services. Cultural access was thought to be as important as Scientific EBM approach. First of all, To evoke potential cultural homogeneity from campaigns and press advertisement was needed for promoting public awareness about preventing winter disease in the summer by enhancing immunity via acupoint applying treatment in the three dog days, and then indigenous name as Sambokcheop, protocol, Clinical Research Form for data collection of it should be developed and prepared. Once the first step was taken this summer, through a thorough data collection and scrutinized scientific evaluation, drawbacks should be compensted for and the efficacy and safety should be substantiated.

CBCT을 이용한 ExacTrac 6D 영상유도방사선치료법의 정확도 평가 (Evaluation of accuracy in the ExacTrac 6D image induced radiotherapy using CBCT)

  • 박호춘;김효중;김종덕;지동화;송주영
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.109-121
    • /
    • 2016
  • ExacTrac 6D couch를 이용한 영상유도 방사선 치료의 정확도를 검증하기 위하여 여섯 개의 방향의 오차 값을 임의로 부여하여 교정 한 후 CBCT 이미지와 비교 분석하여 ExacTrac의 정확도를 평가 하고자 하였다. Rando head Phantom의 치료좌표 값을 X, Y, Z 방향으로 이동시킨 Translationgroup과 pitch, Roll, Yaw방향으로 이동시킨 Rotationgroup으로 나누어 교정하였다. 교정 수치는 couch의 여섯 개의 방향으로 복합적으로 상호 작용하여 이동 하였다. 교정 값은 최소 1mm, 최대 23mm까지 다양하게 나타났다. 치료좌표로 수정된 Phantom를 CBCT 촬영한 이미지와 3D/3D matching 오차 값의 분석에서는 Rotation group에서 높은 오차 값이 나타났다. CBCT로 교정된 치료좌표 오차 값에 대한 선량분포의 비교에서는 정상조직에 선량 제한치 값은 처방선량에 충족되었으며 종양조직의 선량 균질성 지표인 PHI, PCI 값은 Rotation group에서 저 선량 분포영역이 다소 높음으로 나타났다. 본 연구에서는 ExacTrac 6D couch 의 정확도에 대한 평가를 CBCT를 이용하여 검증해 보았다. 단편적인 이동에 대한 오차 값은 비교적 정확한 교정 능력을 갖추고 있었지만, couch에 각이 들어가는 이동에서는 부정확한 교정 수치를 보였다. 환자의 체위가 Rotation방향으로 많은 변화가 예상되어지거나 ExacTrac 교정하였을 때 pitch, Roll, Yaw값의 오차가 크게 나타나면 CBCT 영상유도를 시행하여 정확히 치료 좌표를 교정하여 예상치 못한 부작용을 최소화해야 된다고 여겨진다.

  • PDF

경상분지 북동부의 제3기 결정질 응회암에서 발달하는 미세균열의 분포특성 (Distributional Characteristics of Microcrack in Tertiary Crystalline Tuff from Northeastern Gyeongsang Basin)

  • 박덕원;이창범
    • 암석학회지
    • /
    • 제18권4호
    • /
    • pp.315-336
    • /
    • 2009
  • 경상분지 북동부 일대의 제3기 결정질 응회암에서 발달하는 미세균열의 빈도수, 길이 및 밀도에 대한 분포특성을 도출하였다. 포항시 흥해읍 지역에서 채취한 3개 암석시료의 수평면 상에서 발달하는 134조의 미세균열은 박편의 확대사진을 통하여 구별하였다. 채취지점의 고도를 달리하는 3개 암석시료에 대한 미세균열의 길이-빈도 히스토그램에 대한 형태의 변화성을 도출하였다. 히스토그램들의 분포형태는 암석시료의 고도와 비례하여 음의 지수함수의 분포형에서 대수-정규의 분포형으로 점변한다. 다른 암석시료보다 고도가 낮은 암석시료 1의 분포형태는 넓은 길이분포를 보여주며, 다른 암석시료에 비하여 평균길이와 중앙값, 그리고 표준 편차가 높은 것이 특징이다. 한편 이와 같은 분포특성은 하부 경상누층군의 퇴적암에서 발달하는 절리의 길이분포와 부합한다. $N0{\sim}10^{\circ}W$의 방향을 중심으로 하여 NW 및 NE의 양쪽 방향으로 갈수록 보다 길이가 짧은 미세균열의 출현빈도수는 증가하며, $N80{\sim}90^{\circ}W$$N80{\sim}90^{\circ}E$의 방향에서 각각 우세하다. 이러한 분포특성은 미세균열 조들 사이의 생성시기의 상대적인 차이 그리고 보다 짧은 미세균열의 신규 발생을 의미한다. 한편 $N60{\sim}70^{\circ}W$(최대길이:1.18 mm) 및 $N0{\sim}10^{\circ}W$(최대길이:0.80 mm)의 방향에서는 길이가 가장 긴 미세균열을 볼 수 있으며, 이러한 유형의 미세균열은 빈도수에 비하여 숫적으로 매우 제한적이다. 방향각($\theta$)-빈도수(N), 총길이($L_t$), 평균길이($L_m$) 및 밀도($\rho$)의 종합 분포도의 전 영역은 상관곡선의 형태에 의거, 5개의 구간으로 분류할 수가 있다. 분포도에서 밀도곡선은 서북서-동남동($N70{\sim}80^{\circ}W$), 남-북~북북동-남남서($N0{\sim}10^{\circ}W/N10{\sim}20^{\circ}E$), 동북동-서남서($N50{\sim}60^{\circ}E$) 그리고 거의 동-서($N80{\sim}90^{\circ}E$)의 방향에서 각각 5개의 뚜렷한 정점을 보여준다. 특히 단층의 주방향은 밀도가 높은 방향각과 부합한다. 결과적으로 밀도곡선의 이러한 분포형태는 기존의 연구에서 시사한 대표적인 최대 주응력 방향을 반영한다.

경상분지 남단 고성지역의 백악기 유천층군에 대한 고자기 연구 (Palaeomagnetism of the Cretaceous Yuchon Group in Kosong Area, Southern Kyongsang Basin)

  • 강희철;김인수
    • 한국지구과학회지
    • /
    • 제21권6호
    • /
    • pp.663-674
    • /
    • 2000
  • 경상분지내 밀양소분지의 남단인 경남 고성지역에 분포하는 백악기 유천층군의 19개 장소로부터 총 165개의 독립정향시료를 채취하여 단계적 교류 잔기세척과 열 자기세척 실험을 실시하였다. 그 결과 14개 장소 95개의 시료로부터 정자화와 역자화가 서로 반평행을 이루는 특성잔류자기(ChRM)를 구하였다. 이들의 평균방향은 지층경사 보정전에는 d=26.0$^{\circ}$, i=49.4$^{\circ}$ (${\alpha}_{95}$=8.2$^{\circ}$, k=24.5, n=14)이며 지층경사 보정후에는 d=28.1$^{\circ}$, i=54.2$^{\circ}$ (${\alpha}_{95}$=4.8$^{\circ}$ , k=70.6, n= 14)이었다. 지층경사 보정을 통하여 군집지수 k값이 2.88배 증가하는 사실은 이 특성잔류자기가 99%,의 신뢰도로서 지층의 습곡이나 경동 이전에 획득된 잔류자기임을 지시하는 것이다. 이 평균 잔류자기 방향으로부터 계산된 고자기학적 자북의 위치(palaeomagnetic pole)는 67.0$^{\circ}$N, 210.6$^{\circ}$ E (dp=4.7$^{\circ}$, dm=6.7$^{\circ}$)인 바, 이는 경상분지내 다른 지역이나 남, 북중국 및 유라시아의 백악기 고자기학적 자북의 위치와 거의 일치한다. 따라서 본 연구지역을 포함하는 한반도가 백악기 이후 유라시아 대륙의 한 부분으로서 현재의 상대적 위치를 크게 벗어나지 않았음을 알 수 있다. 한편, 고성층에서 최소 3번의 극성변화가 나타나며 그 상위의 안산암류와 용결응회암에서도 정자화와 역자화가 함께 나타나는 사실을 범세계적 자기층서표와 비교하여 볼 때, 연구대상 유천층군의 연령은 하양층군과 유천층군의 경계인 후기 Albian 에서부터 polarity chron 32r 내지 31r anomaly가 나타나는 초기 Maastrichtian에 이르는 것으로 판단된다. 연구대상 고성층과 그 상위의 안산암에서 여러차례의 역자화가 관찰되는 반면에, 부산지역의 다대포층에서는 하부의 2개 층준에서만 짧은 역자화가 관찰되고 그 상위의 안산암에서는 정자화만 나타난다. 따라서 고성층과 다대포층이 시간층서적으로 상호 대비될 가능성은 거의 없는 것이다.

  • PDF

생명공학과 여성의 행위성: 시험관아기 시술과 배아복제 연구 사이에서 (Biotechnology and Women's Agency: Between IVF and Therapeutic Cloning Research)

  • 조주현
    • 과학기술학연구
    • /
    • 제5권1호
    • /
    • pp.93-123
    • /
    • 2005
  • 이 글은 서로 층위가 다른 제 사회세력들이 시험관아기 시술을 매개로 어떤 방식으로 여성의 재생산권과 모성의 의미를 구성하는지를 밝히고, 시험관아기 시술을 통해 부상하게 된 기술과학주체(technoscientific subject)인 여성은 어떤 위치에 놓여있는지를 논의하는 것을 목적으로 한다. 연구방법은 문헌연구와 심층면접으로써, 과학기술 연구와 페미니즘 관련 문헌들과 심층면접 자료, 불임여성모임 단체와 입양단체의 문건과 회원들이 올린 글들, 언론매체의 기사와 칼럼들을 이용하였다. 불임여성의 경험을 가족 체계, 의료 체계, 그리고 국가 체계를 통해 본 결과는 다음과 같다. 가족의 공간에서 불임여성은 비정상의 범주에 속해질 뿐 아니라 스스로도 자신의 여성성에 의문을 갖지만, 다른 한편 "모성"에 대한 성찰과 확장된 인식을 갖게 되는 계기를 마련하기도 하였다. 의료 공간에서 불임여성은 자신의 몸이 자신 가족, 의료진에게 각기 달리 인식된다는 사실을 경험하게 된다. 몸을 소유한 것도, 소유된 것도 아닌 것으로 인식하는 이 시선은 교환과 거래가 주도하는 공간에 새로운 논리의 창출과 새로운 기술과학주체의 행위성을 예견하게 한다. 국가의 공간에서 배아복제 연구가 국가경쟁력의 기표로 부상함에 따라 난자제공자로서의 여성의 위치도 정치성을 띄게 됐다. 여성은 한편으론 국가발전에 참여할 국민으로 호명되지만 다른 한편으론 "생명"의 존엄성이라는 허구를 지키는 수호자의 역할을 할 것을 요구받는 모순된 위치에 놓여있다. 국가의 경제발전을 위한 기획에 호명되면서 경제적 보상의 범주에는 들지 못하는 국민이라는 정체성과, 생명을 파괴하는 것을 전제로 생명을 창조하는 것을 허락하는 배아복제에 참여하면서 "생명" 수호자의 정체성을 부여받는 것이 각기 내포하는 모순에 대해 여성이 어떻게 순을하고 타협하고 저항할지에 따라 배아복제 연구의 방향과 속도가 달라질 것이다.

  • PDF

잣나무의 재질(材質)에 관(關)한 연구(硏究) (제(第) III 보(報)) - 연륜폭(年輪幅)과 추재율(秋材率) - (Studies on Wood Quality of Pinus koraiensis Sieb. et Zucc. (III) - On Annual Ring Width and Summer Wood Percentage -)

  • 이원용
    • 한국산림과학회지
    • /
    • 제24권1호
    • /
    • pp.25-44
    • /
    • 1974
  • 잣나무조림목(造林木)의 연륜구성(年輪構成)(연륜폭(年輪幅)과 추재율(秋材率)에 관(關)하여 조사(調査)한바 연륜폭(年輪幅)은 변재부(邊材部)에서 좁고 심재부(心材部)에서 넓으나 추재율(秋材率)은 그 분포(分布)가 반대(反對)이며 또한 연륜폭(年輪幅)의 크기는 수간중(樹幹中)에서 수관부(樹冠部)>지하부(枝下部)>지제부(地際部)의 경향(傾向)을 보이고 있는데 반(反)하여 추재율(秋材率)은 지제부(地際部)>지하부(枝下部)>수관부(樹冠部)의 관계(關係)를 가지고 있고 또한 연륜폭(年輪幅)과 추재율(秋材率)은 젊은 영계(齡階)에서는 그 변이(變異)가 심하여 재질(材質)이 비교적(比較的) 불안정(不安定)하나 수심(髓心)으로부터 약(約) 12-15년륜이후(年輪以後)의 재부(材部)에서는 그 변이(變異)가 적어 재질(材質)이 안정(安定)되어 있다. 한편 변재부(邊材部)에서의 연륜폭(年輪幅)과 추재율(秋材率)은 지상고(地上高)의 증가(增加)에 따라 거의 일정불변(一定不變)한 안정(安定)된 영역(領域)과 증감(增減)되는 두 영역(領域)으로 구분(區分)되며 그 한계(限界)가 되는 지상고(地上高)는 약(約) 7m이다. 연륜폭(年輪幅)과 추재율(秋材率)사이에는 부(負)의 상관(相關)이 있다.

  • PDF