Correction of MRI Artifact due to Planar Respiratory Motion (호흡운동에 의한 MRI 아티팩트의 수정)

  • 김응규;김규헌
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1863-1866
    • /
    • 2003
  • In this study, respiratory motion is modeled by a 2-Dimensional linear expanding-shrinking movement. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimated, a reconstruction algorithm based on superposition method was used to removed the MRI artifact. For the purpose of estimating unknown motion parameters, we applied the spectrum shift method to find the respiratory fluctuation function, the x directional expansion coefficient and its center, and also we used the minimum energy method to find the y directional expansion coefficient and its center. The effectiveness of this presented method is shown by Computer simulations.

  • PDF

Super-Resolution Image Processing Algorithm Using Hybrid Up-sampling (하이브리드 업샘플링을 이용한 베이시안 초해상도 영상처리)

  • Park, Jong-Hyun;Kang, Moon-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.109-110
    • /
    • 2007
  • 본 논문에서는 베이시안 초해상도 영상처리시 저해상도 영상들을 고해상도 격자에 맞게 정합해서 업샘플링(upsampling)을 하는 새로운 방식에 대해 제안한다. 제안하는 업샘플링 방식은 각 장을 따로 보간하는 방식과 달리 여러 저해상도 영상의 고주파 정보가 고해상도 영상 격자의 모든 위치에 적절히 영향을 미칠 수 있도록 여러 장의 저해상도 영상의 고주파 정보를 함께 사용하여 보간한다. 보간하는 방법은 B-스플라인 (B-Spline) 기반 비정규 리샘플링(non-uniform resampling)을 기반으로 초해상도 영상처리에 맞도록 적용한다. 실험결과를 통해 일반적으로 적용되는 0-삽입(zero-padding) 업샘플링 방식과 쌍일차 보간법(bilinear interpolation) 등을 적용할 때의 효과를 살펴보고, 제안하는 방식이 일반적인 방식을 사용하는 것에 비해 정량적, 정성적으로 고해상도 정보를 더 정확히 생성해내는 것을 확인한다.

  • PDF

MRI Artifact Correction due to Respiratory Motion (호흡운동에 따른 MRI 아티팩트 수정)

  • 김응규;김규헌
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.58-61
    • /
    • 2003
  • In this study, a planar respiratory motion is modeled by a 2-D linear expanding-shrinking movement. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimated, a construction algorithm based on superposition method was used to remove the MRI artifact. For the purpose of estimating unknown motion parameters, we used the spectrum shift method to find the respiratory fluctuation function, the x directional expansion coefficient and its center, and we also used the minimum energy method to find the y directional expansion coefficient and its center. Finally the effectiveness of this presented method is shown by computer simulations.

  • PDF

NURBS Interpolation Algorithm for CNC Machining with High Speed and High Precision (고속ㆍ고정도 CNC가공을 위한 NURBS 보간 알고리즘)

  • 김민중;송진일;권동수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.192-197
    • /
    • 2000
  • In CNC machining, a free curve is cut into small linear segments using the linear interpolation(G01) method. Therefore, the interpolation error along the curve is not constant due to the changing curvature. This paper presents a NURBS (Non-Uniform Rational B-Spline) interpolation algorithm for machining free curves with high precision and high speed. The proposed NURBS interpolation defines the tool path with NURBS parameters and limits the interpolation error to any desired level by adjusting the feed rate considering the curvature of the shape and sampling time. Both linear and NURBS interpolations are compared to show the validity of the proposed algorithm.

  • PDF

A Study on the Point-Mass Filter for Nonlinear State-Space Models (비선형 상태공간 모델을 위한 Point-Mass Filter 연구)

  • Yeongkwon Choe
    • Journal of Industrial Technology
    • /
    • v.43 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • In this review, we introduce the non-parametric Bayesian filtering algorithm known as the point-mass filter (PMF) and discuss recent studies related to it. PMF realizes Bayesian filtering by placing a deterministic grid on the state space and calculating the probability density at each grid point. PMF is known for its robustness and high accuracy compared to other nonparametric Bayesian filtering algorithms due to its uniform sampling. However, a drawback of PMF is its inherently high computational complexity in the prediction phase. In this review, we aim to understand the principles of the PMF algorithm and the reasons for the high computational complexity, and summarize recent research efforts to overcome this challenge. We hope that this review contributes to encouraging the consideration of PMF applications for various systems.

Estimation algorithm of ocean surface temperature flow based on Morphological Operation (형태학적 연산에 기반한 해수면 온도 분포 추정 알고리즘)

  • Gu, Eun-Hye;Cho, Woong-Ho;Park, Kil-Houm
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.2
    • /
    • pp.253-260
    • /
    • 2012
  • Target detection is very difficult with complex clutters in IRST(Infrared Search and Track) system for a long distance target. Especially sea-clutter and ocean-surface with non-uniform temperature distribution make it difficult to detect incoming targets in images obtained in sea environment. In this paper, we propose a novel method based on morphological method for estimation of ocean surface with non-uniform temperature flow. In order to estimate the exact ocean surface temperature flow, we divided it into upper and lower bound flow. And after estimating it, the final ocean surface temperature flow is derived by a mean value of the estimated results. Also, we apply the multi-weighted technique with a variety of sizes of structure elements to overcome sub-sampling effect by using morphology method. Experimental results for ocean surface images acquired from many different environments are compared with results of existing method to verify the performance of the proposed methods.

INTRODUCTION OF NUC ALGORITHM IN ON-BOARD RELATIVE RADIOMERIC CALIBRATION OF KOMPSAT-2

  • Song, J.H.;Choi, M.J.;Seo, D.C.;Lee, D.H.;Lim, H.S.
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.504-507
    • /
    • 2007
  • The KOMPSAT-2 satellite is a push-broom system with MSC (Multi Spectral Camera) which contains a panchromatic band and four multi-spectral bands covering the spectral range from 450nm to 900nm. The PAN band is composed of six CCD array with 2528 pixels. And the MS band has one CCD array with 3792 pixels. Raw imagery generated from a push-broom sensor contains vertical streaks caused by variability in detector response, variability in lens falloff, pixel area, output amplifiers and especially electrical gain and offset. Relative radiometric calibration is necessary to account for the detector-to-detector non-uniformity in this raw imagery. Non-uniformity correction (NUC) is that the process of performing on-board relative correction of gain and offset for each pixel to improve data compressibility and to reduce banding and streaking from aggregation or re-sampling in the imagery. A relative gain and offset are calculated for each detector using scenes from uniform target area such as a large desert, forest, sea. In the NUC of KOMPSAT-2, The NUC table for each pixel are divided as HF NUC (high frequency NUC) and LF NUC (low frequency NUC) to apply to few restricted facts in the operating system ofKOMPSAT-2. This work presents the algorithm and process of NUC table generation and shows the imagery to compare with and without calibration.

  • PDF

Compensation Methods for Non-uniform and Incomplete Data Sampling in High Resolution PET with Multiple Scintillation Crystal Layers (다중 섬광결정을 이용한 고해상도 PET의 불균일/불완전 데이터 보정기법 연구)

  • Lee, Jae-Sung;Kim, Soo-Mee;Lee, Kwon-Song;Sim, Kwang-Souk;Rhe, June-Tak;Park, Kwang-Suk;Lee, Dong-Soo;Hong, Seong-Jong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.52-60
    • /
    • 2008
  • Purpose: To establish the methods for sinogram formation and correction in order to appropriately apply the filtered backprojection (FBP) reconstruction algorithm to the data acquired using PET scanner with multiple scintillation crystal layers. Materials and Methods: Formation for raw PET data storage and conversion methods from listmode data to histogram and sinogram were optimized. To solve the various problems occurred while the raw histogram was converted into sinogram, optimal sampling strategy and sampling efficiency correction method were investigated. Gap compensation methods that is unique in this system were also investigated. All the sinogram data were reconstructed using 20 filtered backprojection algorithm and compared to estimate the improvements by the correction algorithms. Results: Optimal radial sampling interval and number of angular samples in terms of the sampling theorem and sampling efficiency correction algorithm were pitch/2 and 120, respectively. By applying the sampling efficiency correction and gap compensation, artifacts and background noise on the reconstructed image could be reduced. Conclusion: Conversion method from the histogram to sinogram was investigated for the FBP reconstruction of data acquired using multiple scintillation crystal layers. This method will be useful for the fast 20 reconstruction of multiple crystal layer PET data.

Plasma Hormones, Blood Metabolites, Milk Yield and Composition in Early Lactation of Buffaloes Treated with Bromocryptine

  • Saha, A.;Singh, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.4
    • /
    • pp.368-374
    • /
    • 1998
  • The study was conducted on six multiparous Murrah buffaloes which were earlier artificially induced into lactation. During the experimental period of 15 days, buffaloes were managed in a loose housing system. All the buffaloes were administered a single injection of bromocryptine (@ $100{\mu}g/kg$ body weight) subcutaneously in the neck region at 08:30 A.M., 50 days postpartum (early lactation). Blood samples were collected from four buffaloes for a period of 5 days before the administration of bromocryptine i.e. on days -5, -4, -3, -2, -1, on day of treatment (day 0) and thereafter daily for a period of 9 days i.e 1, 2, 3, 4, 5, 6, 7, 8 and 9 to determine the hormones and blood metabolites. Homogeneous milk samples from all the buffaloes were collected at morning and evening milkings on days coinciding with the days of blood sampling for analysis of milk constituents. Administration of bromocryptine resulted in a significant inhibition of plasma prolactin within 24 hrs of treatment, but the response in all the buffaloes was not uniform. The effect of bromocryptine on plasma prolactin hormone lasted for 1-4 days but Cortisol concentration were not altered. Administration of bromocryptine neither affected blood glucose nor plasma non-esterified fatty acids concentration. Irrespective of level of milk production from different buffaloes, there was no effect of bromocryptine on milk yield which indicated that prolactin is not required for milk secretion during early lactation in buffaloes. Milk constituents like fat, protein and lactose were not affected by bromocryptine may be due to no effect of bromocryptine of milk yield.

MRI Artifact Correction due to Unknown Respiratory Motion (미지 호흡운동에 의한 MRI 아티팩트의 수정)

  • 김응규
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.5
    • /
    • pp.53-62
    • /
    • 2004
  • In this study, an improved post-processing technique for correcting MRI artifact due to the unknown respiratory motion in the imaging plane is presented. Respiratory motion is modeled by a two-Dimensional linear expending-shrinking movement. Assuming that the body tissues are incompressible fluid like materials, the proton density per unit volume of the imaging object is kept constant. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimatead a reconstruction algorithm based on biliner superposition method was used to correct the MRI artifact. In the case of motion parameters are unknown, first, the spectrum shift method is applied to find the respiratory fluctuation function, x directional expansion coefficient and x directional expansion center. Next, y directional expansion coefficient and y directional expansion center are estimated by using the minimum energy method. Finally, the validity of this proposed method is shown to be effective by using the simulated motion images.