Browse > Article

MRI Artifact Correction due to Unknown Respiratory Motion  

김응규 (한밭대학교 정보통신ㆍ컴퓨터공학부)
Publication Information
Abstract
In this study, an improved post-processing technique for correcting MRI artifact due to the unknown respiratory motion in the imaging plane is presented. Respiratory motion is modeled by a two-Dimensional linear expending-shrinking movement. Assuming that the body tissues are incompressible fluid like materials, the proton density per unit volume of the imaging object is kept constant. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimatead a reconstruction algorithm based on biliner superposition method was used to correct the MRI artifact. In the case of motion parameters are unknown, first, the spectrum shift method is applied to find the respiratory fluctuation function, x directional expansion coefficient and x directional expansion center. Next, y directional expansion coefficient and y directional expansion center are estimated by using the minimum energy method. Finally, the validity of this proposed method is shown to be effective by using the simulated motion images.
Keywords
MRI; Spectrum shift; Post-processing technique; Artifact correction;
Citations & Related Records
연도 인용수 순위
  • Reference
1 HW. Korin, F. Farzaneh, RC. Wright et al, 'Compensation for effects of linear motion in MR imaging', Magnetic Resonance in Med., Vol. 12, pp. 99-113, 1989   DOI
2 ML. Wood and R. M. Henkelman, 'Suppression of respiratory motion artifacts in magnetic resonance imaging', Medical Physics, Vol. 13, No. 6, pp. 794-805, 1986   DOI   ScienceOn
3 E. Atalar and L. Onural, 'A respiratory motion artifact reduction method in magnetic resonance imaging of the chest', IEEE Trans. Medical Imaging, Vo. 10, No. 1, pp. 11-24, 1991   DOI   ScienceOn
4 EM. Haacke and GW. Lenz, 'Improving MR image quality in the presence of motion by using rephasing gradients', AJR, Vol. 148, pp. 1251-1258, Jun. 1987   DOI
5 JK. Reik, AM. Tekalp, WE. Smith et al, 'Out-of-plane motion compensation in multislice spinecho MRI', IEEE Trans. Med. Imag., Vol. 14, pp. 464-470, 1995   DOI   ScienceOn
6 R. L. Ehman and J. P. Felmlee, 'Adaptive technique for high-definition MR imaging of moving structures,' Radiology, Vol. 173, pp. 255-263, 1989   DOI
7 J. P. Felmlee, R. L. Ehman, S. J. Riederer and H. W. Korin, 'Adaptive motion compensation in MR imaging without use of navigator echoes,' Radiology, Vol. 179, pp. 139-142, 1991
8 김응규, 권영도, '촬상단면내의 MRI 체동 아티팩트의 제거', 1999년도 대한전자공학회 하계종합학술대회 논문집, 제22권 제1호, pp. 631-634, 1999
9 김응규, MRI에 있어서 체동 아티팩트의 제거, 대한전자공학회논문지, 제37권-SP편, 제3호, pp. 70-78, 2005. 5
10 Eung-Kyeu Kim et al, 'Cancellation of MRI Motion Artifact in Image Plane', Proceeding of The 2002 Society, IEEE Instrumentation and Measurement Technology Anchorage Alaska, USA, 12 May 2002   DOI
11 ML. Wood, MJ. Shivzi and PL. Stanchev, 'Planar Motion Correction with use of k-space data acquired in Fourier MR imaging', Journal of MRI, Vol. 5, pp. 57-64, 1995   DOI   ScienceOn
12 M. Hedley and H. Yan, 'Suppression of Slice Selection Axis Motion Artifact in MRI,' IEEE Trans. Med. Imaging, Vol.11, No.2, pp.233-237, 1992   DOI   ScienceOn
13 H. Yan and JC. Gore, 'An efficient algorithm for MRI image reconstruction without low spatial frequencies,' IEEE Trans. Med. Imaging, Vol.9, No.2, pp.30-36, 1992   DOI   ScienceOn
14 EM. Haacke, JL. Patrick, DM. Balkely et al, 'Correction for motion artifacts based on a linear expansion model', The fourth annual S.M.R.M. Conference, London, Aug. 1985
15 김응규, '위상 엔코딩 방향의 체동에 의한 MRI 아티팩트의 제거', 1998년도 한국정보과학회 가을학술발표논문집, 제25권 2호, pp. 432-434, 1998
16 Z. Cho, J. P. Jones and M. Singh, Foundations of Medical Imaging, New York, John Wiley, pp. 237-267, 1993
17 김함겸, 박재성, 이혜경, 김대호, 영상진단학, 대학서림, pp.55-74, 1997
18 이성우, 은충기, 문치웅, 박수성, 초기 자기 공명 영상학, 여문각, pp.53-61, 1998
19 M. Hedley, H. Yan and D. Rosenfeld, 'An improved algorithm for 2-D translational motion artifact correction', IEEE Trans. Med. Imaging, Vol. 10, No. 4, pp. 548-553, 1991   DOI   ScienceOn
20 M. Hedley, H. Yan and D. Rosenfeld, 'Motion artifact correction in MRI using generalized projections', IEEE Trans. Med. Imaging, Vol. 10, No. 1, pp.40-46, 1991   DOI   ScienceOn
21 김응규, '회전운동에 기인한 MRI 아티팩트의 제거', 한밭대학교 논문집, 제19권, pp. 303-314, 2002. 12
22 김응규, 이수종, 김규헌, '3차원 강체운동에 의한 MRI 아티팩트의 제거', 한국신호처리시스템학회 추계학술대회논문집, 제4권 1호, pp. 58-61, 2003. 6
23 J. E. Dennisr and R. Schnabel, Numerical Methods for Unconstrained Optimization and Nonlinear Equations, New Jersy, Prentice-Hall, 1993
24 D. J. Nishimura, Introduction to Magnetic Resonance Imaging, textbook EE 369B, Stanford University Press, Stanford, CA, pp.156-167, 1994
25 P. E. Gill, W. Murray, M. H. Wright, Practical Optimization, London, Academic, pp.83-153, 1981
26 J. P. Felmlee, R. L. Ehman and S. J. Riederer, 'Adaptive motion compensation in MR imaging without use of navigator echoes', Radiology, Vol.179, pp.139-142, 1991   DOI