• Title/Summary/Keyword: Non-uniform Electric Field

Search Result 64, Processing Time 0.042 seconds

Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field (불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석)

  • Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Jung, Hae-Eun;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

Dielectric Characteristics of $SF_{6}$ Gas Stressed by VFTO in Inhomogeneous Field (불평등전계중에서 과도과전압에 대한 $SF_{6}$가스의 절연특성)

  • 이복희;이창준;길경석;안창환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.306-309
    • /
    • 1995
  • This paper describes the dielectric characteristics of $SF_{6}$ gas in a non-uniform electric field under overvoltages. The breakdown voltage-time characteristics and the breakdown voltage-gas pressure characteristics are measured within a gas pressure range extending from 0.1 to 0.5 [Mpa] for the plane electrode system with a needle-shaped protrusion. The curvature radius of the needle protrusion is 0.5[mm]. Also, the growth process of the predischarge are simultaneously observed. As a result, it is found that the breakdown mechanism and predischarge phenomena are closely associated with the polarity and waveforms of the testing voltage.

  • PDF

Discharge Characteristics of Surface Discharge Type FFL for LCD Backlighting (LCD 백라이트용 면방전형 FFL의 방전 특성)

  • Lim, M.S.;Yun, S.H.;Shin, Y.S.;Jung, D.Y.;Kwon, S.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1786-1788
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp with High Luminance for LCD Backlighting, Liquid Crystal display(LCDs) demand the use of fluorescent lamp as the backlighting source. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. In spite of its simple structure, the lamp has uniform and stable discharge over entire volume. Till now, we measured the current-voltage(V-I), Firing Voltage, Sustain Voltage for 0.5mm, 1mm electrode gap. In experiment result, long gap cell structure cause high firing voltage. The rising in firing voltage in long gap structure could not be explained by paschen's law because of non-uniform electric field.

  • PDF

A REVIEW OF CANDU FEEDER WALL THINNING

  • Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.568-575
    • /
    • 2010
  • Flow Accelerated Corrosion is an active degradation mechanism of CANDU feeder. The tight bend downstream to Gray loc weld connection, close to reactor face, suffers significant wall thinning by FAC. Extensive in-service inspection of feeder wall thinning is very difficult because of the intense radiation field, complex geometry, and space restrictions. Development of a knowledge-based inspection program is important in order to guarantee that adequate wall thickness is maintained throughout the whole life of feeder. Research results and plant experiences are reviewed, and the plant inspection databases from Wolsong Units One to Four are analyzed in order to support developing such a knowledge-based inspection program. The initial thickness before wall thinning is highly non-uniform because of bending during manufacturing stage, and the thinning rate is non-uniform because of the mass transfer coefficient distributed non-uniformly depending on local hydraulics. It is obvious that the knowledge-based feeder inspection program should focus on both fastest thinning locations and thinnest locations. The feeder wall thinning rate is found to be correlated proportionately with QV of each channel. A statistical model is proposed to assess the remaining life of each feeder using the QV correlation and the measured thicknesses. W-1 feeder suffered significant thinning so that the shortest remaining life barely exceeded one year at the end of operation before replacement. W-2 feeder showed far slower thinning than W-1 feeder despite the faster coolant flow. It is believed that slower thinning in W-2 is because of higher chromium content in the carbon steel feeder material. The average Cr content of W-2 feeder is 0.051%, while that value is 0.02% for W-1 feeder. It is to be noted that FAC is reduced substantially even though the Cr content of W-2 feeder is still very low.

Spectrum analysis of UHF Signals Generated by Defects in a Simulated GIS (모의 GIS 결함에 따른 UHF 신호의 스펙트럼 분석)

  • Joun, J.K.;Kwak, H.R.;Roh, Y.S.;Kim, D.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1797-1799
    • /
    • 2003
  • In this paper, we measured partial discharge inception voltage(PDIV) and frequency spectra of UHF signal under following three cases, (1) a corona discharge due to a non uniform electric field for needle-plate electrode (2) a surface discharge caused by particles attached to a spacer in GIS, (3) free movements of particle in GIS. As a result of the experiment, it was revealed that the PDIV of Case (3) is higher than PDIVs of Case (1) and Case (2). It was also seem that UHF signal frequency spectra of one case are different from those of the other cases.

  • PDF

Estimation of Dielectric Constant of Small Particles Using Negative Dielectrophoresis (Negative Dielectrophoresis를 이용한 미세 입자의 유전율 측정)

  • Lee, Sang-Wook;Kim, Yong-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.422-424
    • /
    • 1996
  • The dielectric constants of small particles are estimated using negative dielectrophoresis(DEP). A pair of cylindrical electrodes is proposed to produce a non-uniform electric field that levitates a dielectric particle. Measuring the height of the levitated particle, we can calculate the effective polarizability, and estimate the dielectric constant of the particle using a nonlinear regression method. By determining dielectric constant of polystyrene and polychloromethylstyrene particle, the proposed electrode structure and method show the possibility to measure the dielectric constants of dielectric particles.

  • PDF

Characteristics of Dielectries in $SF_6$ Accoding to a change in Temperature (온도변화에 따른 $SF_6$ 가스의 절연특성)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Geon-Hun;Lee, Kyu-Sun;Kim, Dong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1436-1437
    • /
    • 2007
  • This paper presents the experimental results of the dielectric characteristics with temperature changes under highly non-uniform electric field in $SF_6$ gas. The impulse preliminary breakdown developments were investigated by the measurement of predischarge current and breakdown voltage. As a result, the first stremer corona is initiated at the tip of needle electrode, and bridges the test gap. Also the first stremer corona onset and breakdown voltages the negative polarity was much higher than that in the positive polarity in same temperature. In addition, the varition of temperature have a little effect on the positive polarity. On the other hand, in some cases negative polarity corona onset and breakdown voltages increased with increasing a high temperature.

  • PDF

Breakdown Characteristics of $SF_{6}/N_{2}$ Gas Mixtures According to a change in Temperature (온도변화에 따른 $SF_{6}/N_{2}$ 혼합가스의 절연특성)

  • Lee, Bok-Hee;Li, Feng;Choi, Jong-Hynk;Baek, Young-Hwan;Jeong, Dong-Chul;Kim, Seong-Weon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1455-1456
    • /
    • 2007
  • This paper presents the experimental results on impulse breakdown characteristics under a highly non-uniform electric field in $SF_{6}/N_{2}$ gas mixtures according to a change in temperature. Test temperature ranges from $-25^{\circ}C$ to $25^{\circ}C$. The impulse predischarge breakdown developments are investigated by the measurements of current pulse and discharge luminous events. As a result, the predischarge development mechanisms for both positive and negative polarities are same. When increasing the temperature, breakdown voltage due to lightning impulse voltage is increased in negative polarity. On the other hand, when increasing the temperature, breakdown voltage due to lightning impulse voltage is not changed in positive polarity.

  • PDF

Numerical Modeling of a Rectangular Type Inductively Coupled Plasma System (사각형 유도 결합 플라즈마 시스템의 수치 모델링)

  • Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.4
    • /
    • pp.174-180
    • /
    • 2012
  • Low pressure inductively coupled plasma characteristics of argon and oxygen are numerically simulated for a 400 mm rectangular type system with a plasma fluid model. The results showed lower power absorption profile at the corner than a circular one in a 13.56 MHz driven 1.5 turn antenna system with a drift-diffusion and quasi-neutrality assumption. Ions controlled by electric field are more non-uniform than metastables and the power absorption profile of oxygen plasma is affected by horizontal gas flow pattern to show 25% lower power absorption at the pumping flange side. Oxygen negative ions which are generated in electron collisional dissociation of oxygen molecules was calculated as 0.1% of oxygen atoms with similar spatial profile.

Characteristics of a 190 kVA Superconducting Fault current Limiting Element (190 kVA급 초전도한류소자의 특성)

  • Ma, Y.H.;Li, Z.Y.;Park, K.B.;Oh, I.S.;Ryu, K.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.