• Title/Summary/Keyword: Non-structure

Search Result 5,454, Processing Time 0.033 seconds

An Experimental Study on the Thermal Performance by the Type of Thermal Insulation in Basement Structures (지하외벽체의 단열유형별 열성능에 관한 실험적 연구)

  • Lee, J.Y.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.73-80
    • /
    • 2002
  • This is study of the planning of thermal insulation to prevent heat loss in a basement, is aimed at investigating the heat loss from the basement space and basement structures. The results analyzed in these researches are as follows; To analyze the heat loss from basement structures, this study experimented on the heat flow phenomenon of a non-insulation structure and two insulation structure models. From the result, the interior surface temperature of two insulation structures(B, C, model) showed an equal temperature, but the interior surface temperature of a non-insulation structure (A model) is different from the two models, Therefore, we understand that the insulator constructed in the basement structure makes a role of preventing the heat loss from the basement. In addition, the exterior surface temperature of two insulation structure models showed an equal temperature. Specially, judging from the temperature difference of C model. we understand that the performance of insulator is low under the definite depth of underground. The thermal insulation design should be constructed under the definite depth of underground considering outdoor and building conditions.

Effect of Dealloying Condition on the Formation of Nanoporous Structure in Melt-Spun Al60Ge30Mn10 Alloy

  • Kim, Kang Cheol;Kim, Won Tae;Kim, Do Hyang
    • Applied Microscopy
    • /
    • v.46 no.3
    • /
    • pp.160-163
    • /
    • 2016
  • Effect of dealloying condition on the formation of nanoporous structure in melt-spun $Al_{60}Ge_{30}Mn_{10}$ alloy has been investigated in the present study. In as-melt-spun $Al_{60}Ge_{30}Mn_{10}$ alloy spinodal decomposition occurs in the undercooled liquid during cooling, leading to amorphous phase separation. By immersing the as-melt-spun $Al_{60}Ge_{30}Mn_{10}$ alloy in 5 wt% HCl solution, Al-rich amorphous region is leached out, resulting in an interconnected nano-porous $GeO_x$ with an amorphous structure. The dealloying temperature strongly affects the whole dealloying process. At higher dealloying temperature, dissolution kinetics and surface diffusion/agglomeration rate become higher, resulting in the accelerated dealloying kinetics, i.e., larger dealloying depth and coarser pore-ligament structure.

Non-uniform leaky wave structure composed of finite way of slits on the upper wall of a parallel-plate waveguide (평행평판 도파관 윗면에 위치한 유한한 슬릿배열로 구성된 비균일한 누설파 구조)

  • 이종익;조영기
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.12-20
    • /
    • 1998
  • The non-uniform leaky wave structure of the slits in a parallel-plate waveguide is analyzed from the viewpoints of transmitting(receiving) leaky wave antenna and grating coupler. Period and slit width are simultaneously varied along the leaky wave structure to construct the leaky wave structure with a specific distribution of complex propagation constant. Some results for the equivalent magnetic current distributions over the slits and the radiation characteristics of the leaky wave structure with various source(equivalent magnetic current) distributions such as Gaussian, uniform, cosine, cosine-squared, and Taylor distributions are given and compared with each other.

  • PDF

A Study on the Formulation of the Interaction Problem between Upper Structure and the Ground under Consolidation (上部 構造와 下部 壓密地盤 間 상호작용 문제의 정식화에 대한 연구)

  • Lee, Oe-Duck
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.1 s.31
    • /
    • pp.51-61
    • /
    • 1999
  • When a structure is built on the ground under consolidation, the instant corresponding contact pressure which the upper structure exerts on the ground is established. But, as the consolidation of the ground proceeds, the contact pressure is changed because of the flexural rigidity of the upper structure. This varied contact pressure exerts influence on the consolidation behavior of the ground. And, this varied consolidation behavior exerts on the contact pressure in retum. This kind of interaction between the upper struture and the olwer ground under consolidation contimues till all the consolidation process in finished. So this problem cannot be defined as a linear problem. In this paper an approximation method which can analyse this non-linear interaction problem is proposed by the FEM.

  • PDF

Application of the Runge Kutta Discontinuous Galerkin-Direct Ghost Fluid Method to internal explosion inside a water-filled tube

  • Park, Jinwon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.572-583
    • /
    • 2019
  • This paper aims to assess the applicability of the Runge Kutta Discontinuous Galerkin-Direct Ghost Fluid Method to the internal explosion inside a water-filled tube, which previously was studied by many researchers in separate works. Once the explosive charge located at the inner center of the water-filled tube explodes, the tube wall is subjected to an extremely high intensity fluid loading and deformed. The deformation causes a modification of the field of fluid flow in the region near the water-structure interface so that has substantial influence on the response of the structure. To connect the structure and the fluid, valid data exchanges along the interface are essential. Classical fluid structure interaction simulations usually employ a matched meshing scheme which discretizes the fluid and structure domains using a single mesh density. The computational cost of fluid structure interaction simulations is usually governed by the structure because the size of time step may be determined by the density of structure mesh. The finer mesh density, the better solution, but more expensive computational cost. To reduce such computational cost, a non-matched meshing scheme which allows for different mesh densities is employed. The coupled numerical approach of this paper has fewer difficulties in the implementation and computation, compared to gas dynamics based approach which requires complicated analytical manipulations. It can also be applied to wider compressible, inviscid fluid flow analyses often found in underwater explosion events.

Characterization of Natvig Type Continuum Structure functions

  • Lee, Seung-Min
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2002.06a
    • /
    • pp.305-305
    • /
    • 2002
  • A continuum structure function is a non-decreasing mapping from the unit hypercube to the unit interval. Within the class of continuum structure functions, new axiomatic characterizations of the Natvig and the Barlow-Wu subclass are obtained.

  • PDF

KILLING STRUCTURE JACOBI OPERATOR OF A REAL HYPERSURFACE IN A COMPLEX PROJECTIVE SPACE

  • Perez, Juan de Dios
    • Journal of the Korean Mathematical Society
    • /
    • v.58 no.2
    • /
    • pp.473-486
    • /
    • 2021
  • We prove non-existence of real hypersurfaces with Killing structure Jacobi operator in complex projective spaces. We also classify real hypersurfaces in complex projective spaces whose structure Jacobi operator is Killing with respect to the k-th generalized Tanaka-Webster connection.

How is the Compensation Structure of Family Firms Different from that of Non-Family Firms? : Evidence from Korea (가족기업과 비가족기업의 경영자 보상 구조의 차이에 관한 연구)

  • Yoo, Jungmin;Yoon, Dae-Hee
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.38 no.2
    • /
    • pp.179-196
    • /
    • 2013
  • This paper examines the difference in compensation structure between family firms and non-family firms in Korea. A manager's compensation is an important means of motivating a manager to make decisions for shareholders by mitigating conflicts of interest between them. However, the role of a manager's compensation can be weakened in family firms for the following reasons. First, a family member manager has fewer conflicts of interest, compared to a non-family member manager. Second, a family member manager has an intrinsic incentive to increase a firm's value (i.e., family wealth). Finally, a family member manager can monitor non-family member managers more effectively. For the reasons, the agency problem will be less severe in family firms and subsequently the role of compensation will be reduced. The empirical results show that pay-performance sensitivity is smaller in family firms than in non-family firms. The main result is robust to variations such as changes in family ownership, the definition of a family firm, and control variables. Furthermore, this paper compares the pay-performance sensitivity of Chaebol family firms with that of other firms. The result shows that the sensitivity is higher for Chaebol family firms, compared to that in other family firms and non-family firms.

An Optimal Die Design for the Coating Uniformity of Non-Newtonian Liquids in Slot Coating Process (Slot 코팅 공정에서 Non-Newtonian 유체의 코팅 균일성을 위한 최적 다이 설계)

  • Lee, Si-Hyung;Koh, Hyun-Jung;Shim, Seo-Hoon;Jung, Hyun-Wook;Hyun, Jae-Chun
    • Korean Chemical Engineering Research
    • /
    • v.49 no.3
    • /
    • pp.314-319
    • /
    • 2011
  • In this study, the flow behavior of Newtonian and non-Newtonian coating liquids inside slot die has been scrutinized for the purpose of optimal internal die design in slot coating system from three-dimensional computations by CFD Fluent solver. A hybrid slot die could be optimally designed by changing the chamber or manifold structure to guarantee the uniform velocity distribution of coating liquids at die exit. Especially, for the non-Newtonian coating liquids, the length of coat-hanger for the uniform coating has been properly chosen, according to the degree of their shearthinning properties.

An Reliable Non-Volatile Memory using Alloy Nano-Dots Layer with Extremely High Density

  • Lee, Gae-Hun;Kil, Gyu-Hyun;An, Ho-Joong;Song, Yun-Heup
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.241-241
    • /
    • 2010
  • New non-volatile memory with high density and high work-function metal nano-dots, MND (Metal Nano-Dot) memory, was proposed and fundamental characteristics of MND capacitor were evaluated. In this work, nano-dot layer of FePt with high density and high work-function (~5.2eV) was fabricated as a charge storage site in non-volatile memory, and its electrical characteristics were evaluated for the possibility of non-volatile memory in view of cell operation by Fowler-Nordheim (FN)-tunneling. Here, nano-dot FePt layer was controlled as a uniform single layer with dot size of under ~ 2nm and dot density of ${\sim}\;1.2{\times}10^{13}/cm^2$. Electrical measurements of MOS structure with FePt nano-dot layer shows threshold voltage window of ~ 6V using FN programming and erasing, which is satisfied with operation of the non-volatile memory. Furthermore, this structure provides better data retention characteristics compared to other metal dot materials with the similar dot density in our experiments. From these results, it is expected that this non-volatile memory using FePt nano-dot layer with high dot density and high work-function can be one of candidate structures for the future non-volatile memory.

  • PDF