• Title/Summary/Keyword: Non-staggered

Search Result 112, Processing Time 0.027 seconds

Analysis of Convective Heat Transfer Characteristics for the Compact Heat Exchanger with Flat Tubes and Plate Fins Having a Non-symmetric Staggered Arrangements (비대칭 엇갈림 배열로 구성된 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 특성 해석)

  • Moh, Jeong-Hah;Lee, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.5
    • /
    • pp.318-325
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchanger with flat tubes and continuous plate fins having a symmetric and non-symm etric staggered arrangements. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental results. In order to investigate the flow and heat transfer features by periodic boundary conditions, the three blocks were used. Predicted heat transfer coefficients between the three blocks are similar while there are relatively differences, compared with the experimental data. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.

Control Effects on the Aerodynamic Forces and Wake Structures by a Spinning Cylinder in Staggered Arrangement (엇갈림 배열에서 회전원주에 의한 정지원주의 공력 및 후류유동 제어)

  • 부정숙;류병남;심정훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.857-868
    • /
    • 2001
  • The aerodynamic forces and wake structures of the non-rotating downstream cylinder which is located behind the spinning upstream cylinder in tandem and staggered arrangement have been investigated by experimental method at Re= $1.32{\times}10^4$. The measurements of wake flow and pressure distributions of downstream cylinder are carried out in various spin parameters by combination of both longitudinal spacing rations L/d=1.5, 3.0, 4.5 and transverse spacing ratios T/d =0.0, -0.5, 0.5. For the present experiment, it has been found that the spin parameter of spinning upstream cylinder affect more easily the downstream cylinder in tandem arrangement than that in staggered arrangement.

  • PDF

Numerical Analysis of Turbulent Flow and Heat Transfer Normal to a Staggered Tube Bank (교차된 관군에 수직한 난류유동 및 난류열전달의 수치해석)

  • 이건휘;이병곤;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.218-228
    • /
    • 1991
  • Since heat exchangers are composed of bank of tubes, the knowledge on the flow and heat transfer characteristics of the tube bank are required for the optimum design and selection of heat exchangers. In this paper, the turbulent flow fields and heat transfers normal to a staggered tube bank are solved numerically employing K-.epsilon. 2 equation turbulence model and non-orthogonal coordinate transformation for the treatment of curved surface of tubes. Predicted mean Nusselt numbers of tube bank agree reasonably well with Grimision's correlation

Prediction of Non-Contact-Type Seal Leakage Using CFD (CFD를 사용한 터보기계 비접촉식 실의 누설량 예측)

  • Ha Tae-Woong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.14-21
    • /
    • 2006
  • Leakage reduction through annular type seals of turbomachinery is necessary for enhancing their efficiency and the precise prediction method of seal leakage is needed. The analysis based on Bulk-flow concept has been mainly used in predicting seal leakage. However, full Navier-Stokes Equations with turbulent model derived in the seal flow passage have to be solved for improving the prediction of seal leakage. FLUENT 6 which is commercial CFD(Computational Fluid Dynamics) code based on FVM(Finite Volume Method) and SIMPLE algorism has been used to analyze leakage of various non-contact-type seals in this presentation. Comparing with the results of Bulk-flow model analysis and experiment, the result of CFD analysis shows good agreement with that of existing theoretical analysis for the incompressible grooved seal and compressive plain and staggered seal. The CFD analysis also shows improvement on the leakage prediction of the incompressible plain seal and compressive see-through-type labyrinth seal.

A Finite Volume Method for Computations of Two-Dimensional Laminar Flows (이차원 층류유동 해석을 위한 유한체적법)

  • Kim, Ki-Sup;Chung, Myung-Kyoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.3
    • /
    • pp.59-70
    • /
    • 1992
  • A Finite volume method for the computation of the two-dimensional, incompressible, steady, laminar Navier-Stokes equation is developed using a non-staggered grid system in a general curvilinear coordinate. The numerical pressure fluctuations, usually encountered when the non-staggered grid system is used, is suppressed by the momentum interpolation method. Flows around a NACA0012 foil section have been computed by the present method and the results show good agreements with other experimental and numerical ones.

  • PDF

The Mixed Finite Element Analysis for Nearly Incompressible and Impermeable Porous Media Using Parallel Algorithm (병렬알고리즘 이용한 비압축, 비투과성 포화 다공질매체의 혼합유한요소해석)

  • Tak, Moon-Ho;Kang, Yoon-Sik;Park, Tae-Hyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.361-368
    • /
    • 2010
  • In this paper, the parallel algorithm using MPI(Message-Passing Interface) library is introduced in order to improve numerical efficiency for the staggered method for nearly incompressible and impermeable porous media which was introduced by Park and Tak(2010). The porous media theory and the staggered method are also briefly introduced in this paper. Moreover, we account for MPI library for blocking, non-blocking, and collective communication, and propose combined the staggered method with the blocking and nonblocking MPI library. And then, we present how to allocate CPUs on the staggered method and the MPI library, which is related with the numerical efficiency in order to solve unknown variables on nearly incompressible and impermeable porous media. Finally, the results comparing serial solution with parallel solution are verified by 2 dimensional saturated porous model according to the number of FEM meshes.

The Semi-Implicit Numerical Scheme for Transient Two-Phase Flows on Unstructured Grids (과도 다차원 2상 유동 해석을 위한 비정렬 격자계에서의 Semi-Implicit 수치 해법 개발)

  • Cho, H.K.;Park, I.K.;Yoon, H.Y.;Kim, J.;Jeong, J.J.
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.218-226
    • /
    • 2008
  • A component-scale two-phase analysis code has been developed for a realistic simulation of two-phase flow transients in a light water nuclear reactor component. In the code, a two-fluid three-field model is adopted and the governing equations are solved on an unstructured mesh. For the numerical solution scheme, the semi-implicit method used in the RELAP5 code was selected, which has been proved to be very stable and accurate for most of practical applications. However, some modifications were needed for its application to an unstructured non-staggered grid. This paper presents the modified semi-implicit numerical method for unstructured grid and the preliminary results of the calculations.

Thermal Treatment Effects of Staggered Tunnel Barrier(Si3N4/Ta2O5) for Non Volatile Memory Applications

  • Lee, Dong-Hyeon;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.159-160
    • /
    • 2012
  • 지난 30년 동안 플래시 메모리의 주류 역할을 하였던 부유 게이트 플래시 메모리는 40 nm 기술 노드 이하에서 셀간 간섭, 터널 산화막의 누설전류 등에 의한 오동작으로 기술적 한계를 맞게 되었다. 또한 기존의 비휘발성 메모리는 동작 시 높은 전압을 요구하므로 전력소비 측면에서도 취약한 단점이 있다. 그러나 이러한 문제점들을 기존의 Si기반의 소자기술이 아닌 새로운 재료나 공정을 통해서 해결하려는 연구가 최근 활발하게 진행되고 있다. 특히, 플래시 메모리의 중요한 구성요소의 하나인 터널 산화막은 메모리 소자의 크기가 줄어듦에 따라서 SiO2단층 구조로서는 7 nm 이하에서 stress induced leakage current (SILC), 직접 터널링 전류의 증가와 같은 많은 문제점들이 발생한다. 한편, 기존의 부유 게이트 타입의 메모리를 대신할 것으로 기대되는 전하 포획형 메모리는 쓰기/지우기 속도를 향상시킬 수 있으며 소자의 축소화에도 셀간 간섭이 일어나지 않으므로 부유 게이트 플래시 메모리를 대체할 수 있는 기술로 주목받고 있다. 특히, TBM (tunnel barrier engineered memory) 소자는 유전율이 큰 절연막을 적층하여 전계에 대한 터널 산화막의 민감도를 증가시키고, 적층된 물리적 두께의 증가에 의해 메모리의 데이터 유지 특성을 크게 개선시킬 수 있는 기술로 관심이 증가하고 있다. 본 연구에서는 Si3N4/Ta2O5를 적층시킨 staggered구조의 tunnel barrier를 제안하였고, Si기판 위에 tunnel layer로 Si3N4를 Low Pressure Chemical Vapor Deposition (LPCVD) 방법과 Ta2O5를 RF Sputtering 방법으로 각각 3/3 nm 증착한 후 e-beam evaporation을 이용하여 게이트 전극으로 Al을 150 nm 증착하여 MIS- capacitor구조의 메모리 소자를 제작하여 동작 특성을 평가하였다. 또한, Si3N4/Ta2O5 staggered tunnel barrier 형성 후의 후속 열처리에 따른 전기적 특성의 개선효과를 확인하였다.

  • PDF

Effect of Nonuniform Vertical Grid on the Accuracy of Two-Dimensional Transport Model

  • Lee, Chung-Hui;Cheong, Hyeong-Bin;Kim, Hyun-Ju;Kang, Hyun-Gyu
    • Journal of the Korean earth science society
    • /
    • v.39 no.4
    • /
    • pp.317-326
    • /
    • 2018
  • Effect of the nonuniform grid on the two-dimensional transport equation was investigated in terms of theoretical analysis and finite difference method (FDM). The nonuniform grid having a typical structure of the numerical weather forecast model was incorporated in the vertical direction, while the uniform grid was used in the zonal direction. The staggered and non-staggered grid were placed in the vertical and zonal direction, respectively. Time stepping was performed with the third-order Runge Kutta scheme. An error analysis of the spatial discretization on the nonuniform grid was carried out, which indicated that the combined effect of the nonuniform grid and advection velocity produced either numerical diffusion or numerical adverse-diffusion. An analytic function is used for the quantitative evaluation of the errors associated with the discretized transport equation. Numerical experiments with the non-uniformity of vertical grid were found to support the analysis.