• Title/Summary/Keyword: Non-direct measurement

Search Result 127, Processing Time 0.03 seconds

Effective time-frequency characterization of Lamb wave dispersion in plate-like structures with non-reflecting boundaries

  • Wang, Zijian;Qiao, Pizhong;Shi, Binkai
    • Smart Structures and Systems
    • /
    • v.21 no.2
    • /
    • pp.195-205
    • /
    • 2018
  • Research on Lamb wave-based damage identification in plate-like structures depends on precise knowledge of dispersive wave velocity. However, boundary reflections with the same frequency of interest and greater amplitude contaminate direct waves and thus compromise measurement of Lamb wave dispersion in different materials. In this study, non-reflecting boundaries were proposed in both numerical and experimental cases to facilitate time-frequency characterization of Lamb wave dispersion. First, the Lamb wave equations in isotropic and laminated materials were analytically solved. Second, the non-reflecting boundaries were used as a series of frames with gradually increased damping coefficients in finite element models to absorb waves at boundaries while avoiding wave reflections due to abrupt property changes of each frame. Third, damping clay was sealed at plate edges to reduce the boundary reflection in experimental test. Finally, the direct waves were subjected to the slant-stack and short-time Fourier transformations to calculate the dispersion curves of phase and group velocities, respectively. Both the numerical and experimental results suggest that the boundary reflections are effectively alleviated, and the dispersion curves generated by the time-frequency analysis are consistent with the analytical solutions, demonstrating that the combination of non-reflecting boundary and time-frequency analysis is a feasible and reliable scheme for characterizing Lamb wave dispersion in plate-like structures.

AN INSTURMNETED SEINGLE TREE FOR DIRECT DRAFT MEASUREMENT OF ANIMAL DRAWIN IMPLEMENTS

  • Paskikatan, M.C.;Quick, G.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.307-315
    • /
    • 1993
  • A direct draft measurement system was developed based on the swingle tree- the rear component of the single-animal harnessing (or yoking) system . The prototype was made from a tube, on which four strain gages were attached. The pull of the draft animal through the flexible pull chains or ropes causes the beam to bend, The bending strain is sensed by the strain gages and the bridge converts this to a voltage signal. Counterweights keep the tube correctly oriented if the angle of pull changes , while end bearing follow the variations in the angle of pull. Hence, the voltage output is proportional to the draft. the device has highly linear response, acceptable sensitivity negligible error and hysteresis. It is suitable for electronic data acquisition, non-intrusive , easy to attach and detach and is reasonably priced.

  • PDF

The Effect of Different dietary Patterns (between Non-Vegetarian and Vegetarian) on Protein Nutritional Status during Short-term (식사 Pattern의 차이가 단백질 영양상태에 미치는 영향)

  • 박귀선;김정임
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • The purpose of this study was to describe the protein nutritional status of female collegians between nonvegetarian diet groups(14) and vegetarian diet groups(19). Daily intake, protein were calculated from food direct measurement. Urea/creatinine, muscle mass, fatique conditions and hematological parameter were calculated. Blood samples were analyzed for total protein, albumin ammonia, urea, uric acid, creatinine, BUN contents. The results obtained are summarized as following : 1) On total dietary intake, especially Fe, vitamin C, niacin intake, vegetarian groups were higher than non vegetarian groups. 2) On composition of EAA(essential amino acids), vegetarians were highter than non vegetarian of leucine contents, but were lower lysine and threonine contents. 3) On urea / creatinine excretion, vegetarians were higher than non begetarians. Muscle mass were non signicant, fatique condition, vegetarians were normal state. 4) Non vegetarians were increased serum albumin total protein, uric acid, ammonia but vegetarians were decreased BUN, ammonia after experimental diet intake. 5) In process of time after meal, non vegetarians were increased serum albumin total protein, BUN, but vegetarians were decreased ammonia.

  • PDF

Spectroscopic Studies of TP6F PI Switched by Hole-Injection

  • Lee, Gyeong-Jae;Im, Gyu-Uk;Kim, Dong-Min;Lee, Mun-Ho;Gang, Tae-Hui;Jeong, Seok-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.297-298
    • /
    • 2011
  • Metal/poly (4,4'-aminotriphen-ylene hexafluoroisopropylidenediphthalimide) (TP6F PI)/metal structure exhibited an electrically volatile phase transition with high (OFF) or low (ON) resistive states when voltage between electrodes swept. Here, we demonstrate a noble set-up in which holes are injected by photoelectron emission process during the voltage sweep instead of direct charge carrier injection via metal electrode, which enables direct investigation into changed electronic structures of TP6F PI both in ON and OFF states using photoemission spectroscopy methods. In the I-V measurement, TP6F PI shows a non-volatile behavior. In spectroscopic results, this non-volatile behavior is leaded from the structural modification of the O=C double bond in phthalimide of TP6F PI by hole injection.

  • PDF

A Study on the Transient Measurement of the Effective Thermal Diffusivity of Insulation Materials by NPE Method (NPE법을 이용한 절연재료의 유효열확산계수의 과도측정에 관한 연구)

  • Lim, Dong Joo;Bae, Sin Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.243-255
    • /
    • 1990
  • The objective of this study is to present an efficient measurement method of the effective thermal diffusivity for the fibrous insulation material. The non-linear parameter estimation (NPE) method is adapted for this analysis because of its accuracy and its results are compared with those by other direct methods such as CTP, CHP and STD method. A experimental system is constructed with bell-jar vaccum chamber, diffusion pump, tube type furnace, control unit and data acquisition system included with A/D converter and IBM XT/AT personal computer. The typical results obtained from this study are as follows; 1) NPE method can be recommended as an useful and accurate method to measure the effective thermal diffusivity of insuation material because it is shown that the measurement error compared with those by other direct methods is reduced for standard material, NBS-1450b. 2) NPE method can minimize the effects of ill-measured temperature due to external disturbance, because the final value is found by point to point estimating. 3) NPE method dose not depend on the kinds of heat flux, since the surfac temperature are used to estimate the thermal diffusivity. 4) With NPE method, compared with the steady state method, a measuring time and a sample size could be reduced.

  • PDF

Velocity Measurements of Slurry Flows in CMP Process by Particle Image Velocimetry (Particle Image Velocimetry 기법을 이용한 CMP 공정의 Slurry유동 분석)

  • Kim Mun-Ki;Yoon Young-Bin;Koh Young-Ho;Hong Chang-Gi;Shin Sang-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.59-67
    • /
    • 2006
  • Chemical Mechanical Polishing(CMP) in semiconductor production is characterized its output property by Removal Rate(RR) and Non-Uniformity(NU). Some previous works show that RR is determined by production of pressure and velocity and NU is also largely affected by velocity of flowfield during CMP. This study is about the direct measurement of velocity of slurry during CMP and whole flowfield upon the non-groove pad by Particle Image Velocimetry(PIV). Typical PIV system is modified adequately for inspecting CMP and slurry flowfield is measured by changing both pad rpm and carrier rpm. We performed measurement with giving some variation in the kinds of pad. The results show that the flowfield is majorly determined not by Carrier but by Pad in the case of non-groove pad.

A Study on the Three Dimensional Coordinates Analysis by Direct Linear Transformation (직접선형변환을 이용한 3차원 좌표해석에 관한 연구)

  • 김감래;이호남
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.5 no.2
    • /
    • pp.47-55
    • /
    • 1987
  • In this paper, the direct linear transformation is described in which a inner and exterior orientation parameters are treated as unknown for non-iterative direct space resection, and the computer program was developed to obtain object space coordinates. Image coordinates measurements are conducted with analogue stereo-plotter and digitizer. To prove the appropriateness of the two image coordinate measurement devices and the DLT method, the standard errors of object space coordinates are compared with semi-analytical method.

  • PDF

A simple analysis on the abnormal behavior of the argon metastable density in an inductively coupled Ar plasma

  • Park, Min;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Sin, Yong-Hyeon;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.438-438
    • /
    • 2010
  • The abnormal behavior of the argon metastable density during the E-H mode transition in argon ICP discharge was investigated. Lots of investigations including global models expected that during and after the mode transition of ICP discharge, the density of metastable increases with applied rf power (i.e. electron density). However, recent direct measurement of metastable density revealed that the metastable density of argon decreases with the applied power during and after the mode transition. This result may not be explained by the previous global model which is based on the assumption of the Maxwellian electron energy distribution function (EEDF). In this paper, to explain this abnormal behavior with simple manners, a simple global model taking account of the effect of the non-Maxwellian EEDFs incorporating into a set of coupled rate equations is proposed. The result showed that the calculated metastable density taking account of non-Maxwellian EEDF and its evolution during the transition has an abnormal behavior with electron density and is in good agreement with the previous measurement results, indicating the close coupling of electron kinetics and the behavior of metastable density. The proposed simple model is expected to provide qualitative kinetic insight to understand the behavior of the metastable density in various plasma discharges which typically exhibit non-Maxwellian distribution.

  • PDF

An Experimental Study on Measurement Method for Grain Bulk Modulus of Sandstone (사암의 입자 체적계수 측정 방법에 대한 실험적 연구)

  • Min-Jun Kim;Eui-Seob Park;Chan Park;Junhyung Choi
    • Tunnel and Underground Space
    • /
    • v.33 no.2
    • /
    • pp.71-82
    • /
    • 2023
  • This study presents a direct measurement method for grain bulk modulus, which is important hydraulic-mechanical properties of rock, and conducts the experiment to investigate the grain bulk modulus of sandstone. In addition, the factors affecting the grain bulk modulus were investigated, comparing volumetric characteristics of rocks with different properties. As a result of the experiment, it was confirmed that the theoretically estimated bulk modulus is overestimated than the direct measured one. The possibility of the difference was analyzed, discussing the existence of non-connected pore space due to particle structure of the rock. Finally, the experimental results showed that the direct measurement suggested in this study can reliably predict the grain bulk modulus of sandstone.

A Study on the Wear Monitoring Technique for Diamond Core Drill (다이아몬드 코어 드릴의 마멸 검출에 관한 연구)

  • 유봉환
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.2
    • /
    • pp.38-45
    • /
    • 1995
  • The diagnosis and monitoring system of abnormal cutting condition is necessary to realize precision machining proces and factory automation, which are final goal of metal cutting in order to develop this system, theimage processing technique has been investigated in machining process. In theis paper, the measurement system of tool wear using computer vision is designed to detect the wear pattern by non-contact and direct method and get the realiable wear information about cutting tool. We measured the area of the side and front part of the diamond core dril which is used in 40kHz ultrasonic vibration machine.

  • PDF