• Title/Summary/Keyword: Noise source imaging

검색결과 66건 처리시간 0.025초

Development of hybrid shielding system for large-area Compton camera: A Monte Carlo study

  • Kim, Jae Hyeon;Lee, Junyoung;Kim, Young-su;Lee, Hyun Su;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2361-2369
    • /
    • 2020
  • Compton cameras using large scintillators have been developed for high imaging sensitivity. These scintillator-based Compton cameras, however, mainly due to relatively low energy resolution, suffer from undesired background-radiation signals, especially when radioactive materials' activity is very low or their location is far from the Compton camera. To alleviate this problem for a large-size Compton camera, in the present study, a hybrid-type shielding system was designed that combines an active shield with a veto detector and a passive shield that surrounds the active shield. Then, the performance of the hybrid shielding system was predicted, by Monte Carlo radiation transport simulation using Geant4, in terms of minimum detectable activity (MDA), signal-to-noise ratio (SNR), and image resolution. Our simulation results show that, for the most cases, the hybrid shielding system significantly improves the performance of the large-size Compton camera. For the cases investigated in the present study, the use of the shielding system decreased the MDA by about 1.4, 1.6, and 1.3 times, increased the SNR by 1.2-1.9, 1.1-1.7, and 1.3-2.1 times, and improved the image resolution (i.e., reduced the FWHM) by 7-8, 1-6, and 3-5% for 137Cs, 60Co, and 131I point source located at 1-5 m from the imaging system, respectively.

Near-Infrared Polarization Source Catalog of Northeastern Regions in the Large Magellanic Cloud

  • Kim, Jaeyeong;Jeong, Woong-Seob;Pak, Soojong;Park, Won-Kee;Tamura, Motohide
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.31.2-31.2
    • /
    • 2015
  • We present a near-infrared photometric and polarimetric catalog of sources in the $39^{\prime}{\times}69^{\prime}$ fields on the northeastern part of the Large Magellanic Cloud (LMC), which was observed using SIRPOL, an imaging polarimeter of the Infrared Survey Facility (IRSF). This catalog contains 1,858 sources brighter than 14 mag at H band with polarization signal-to-noise ratio greater than 3 in at least one of J, H, and Ks bands. We examined the polarization structures around the star-forming regions, where coherent polarization position angle distributions are seen. We also estimated magnetic field strengths in some selected fields using Chandrasekhar and Fermi analysis. The magnetic field strengths are estimated to be $3{\sim}25{\mu}G$. The wavelength dependence of polarization degrees indicates that the polarization is most likely to be originated from dichroic extinctions by the local interstellar dusts in the LMC. We found that the polarization patterns are well aligned along the molecular clouds around star-forming regions.

  • PDF

The Large Magellanic Cloud Polarization Source Catalog : Characteristics of Polarization in The Observed Fields

  • Kim, Jaeyeong;Pak, Soojong;Jeong, Woong-Seob;Park, Won-Kee;Pavel, Michael D.
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.62.2-62.2
    • /
    • 2014
  • We compiled near-infrared photometric and polarimetric catalog of sources in ~3 $9^{\prime}{\times}69^{\prime}$ size field in the eastern side of the Large Magellanic Cloud (LMC). This catalog lists all 1969 sources which are brighter than 14 mag and which signal to noise ratio of degree of polarization is greater than 3 in the J, H, and Ks bands. The photometric and polarimetric data were simultaneously obtained in J, H, and Ks bands using SIRPOL, an imaging polarimeter of the InfraRed Survey Facility (IRSF), in 2008 December and 2011 December. We classified the objects into several groups based on their locations on the color-magnitude diagram and compared their general properties of polarization. We measured wavelength dependence of this field to verify interstellar polarization of the LMC which occurred from the dichroic extinction. We also discuss the polarization structure in this field with the results from molecular cloud studies.

  • PDF

뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성 (Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2)

  • 이세지;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.51-57
    • /
    • 2016
  • 뇌 자기공명영상(Magnetic Resornance Imaging; MRI)에서 검사 중 발생되는 소음을 줄이기 위한 기법으로 경사 파형을 변경한 Quiet $T_2$-weighted Turbo Spin-Echo(이하 Q-$T_2$)와 일반적으로 사용되는 $T_2$-weighted Turbo Spin-Echo(이하 $T_2$) 영상의 소음수준 및 영상의 질을 비교하여 그 유용성을 알아보고자 하였다. 3.0T MR 기기로 뇌 MR 검사를 받은 60명(남자 29명, 여자 31명, 평균 연령 60.1세)의 환자를 대상으로 하였다. Q-$T_2$$T_2$ 각각의 영상에서 소음 및 심박동수를 측정하였다. 정량적 분석은 Q-$T_2$$T_2$의 SNR, CNR, SIR 값을 측정한 뒤 독립표본 T검정을 이용하여 통계적 분석을 하였다. 정성적 분석은 Q-$T_2$$T_2$의 전체적인 영상의 질에 대하여 육안으로 평가하였다. 평가는 5점 척도로서 우수(excellent) 5점, 양호(good) 4점, 보통(fair) 3점, 불량(poor) 2점, 평가불가(unacceptable) 1점으로 평가하였다. Q-$T_2$$T_2$ 검사 중 평균소음과 peak소음은 Q-$T_2$가 기존 $T_2$에 비해 각각 $15dB_A$, $10dB_A$ 감소하였다. 또한 각각의 검사 중 120초 동안 심박동수의 평균값은 Q-$T_2$에서 더 낮은 값으로 나타났지만 통계적인 유의성은 없었다. 정량적 분석의 결과 CNR과 SIR은 유의한 차이가 없었으며, SNR은 Q-$T_2$가 더 낮은 평균값을 보임으로서 유의한 차이를 보였다(p<0.05). 정성적 분석은 59개의 Q-$T_2$$T_2$ 영상의 질이 동일하게 우수(excellent) 5점으로 평가되었으며, 1개의 영상에서 모션 아티팩트로 인해 양호(good) 4점으로 평가되었다. Q-$T_2$는 기존의 $T_2$와 같이 검사시간 및 진단의 정확도는 동일하지만 소음을 효과적으로 감소시킬 수 있으며, 이로인하여 환자 편의를 향상시킬 수 있을 것으로 사료된다.

소동물 영상을 위한 MicroPET R4스캐너의 특성평가 (Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging)

  • 이병일;이재성;김진수;이동수;최창운;임상무
    • 대한핵의학회지
    • /
    • 제39권1호
    • /
    • pp.49-56
    • /
    • 2005
  • 목적: 새로운 PET 추적자와 약물 개발, 유전자 및 줄기세포치료 연구 등에 소동물 전용 PET이 유용하게 쓰이고 있으며, 국내에도 최근에 microPET R4 소동물 전용 PET이 설치되어 각종 기초연구에 활발히 이용될 전망이다. 이 연구에서는 국내에 최초로 설치된 microPET R4 스캐너의 물리적 특성(공간분해능, 균일도, 민감도, 산란분획, NECR)을 측정하였다. 대상 및 방법: 내경 0.5 mm의 가는 모세관을 F-18으로 채워 만든 선선원을 이용하여 공간분해능 및 민감도를 측정하였다. 반경방향(radial) 및 접선방향(tangential) 분해능을 측정하기 위하여 60 mm의 선선원(65 ${\mu}Ci$)을 축방향과 나란하게 놓은 후 횡단면상 중앙에서부터 1 mm 간격으로 중심에서 4 cm 벗어난 지점까지 옮겨가며 각 2분간 PET 영상을 얻었다. 축방향(axial) 공간분해능 측정을 위하여서는 선선원을 축방향과 수직으로 놓고 동일한 실험을 반복하였다. PET 영상은 FBP 방법과 OSEM 방법으로 각각 재구성하였으며 가우시안 함수로 곡선정합하여 반치폭값을 구하였다. 축방향 위치에 따른 민감도 측정을 위하여 축방향 시야 길이와 동일한(78 mm) 선선원(16.5 ${\mu}Ci$)을 횡단면 중심에 축방향과 나란하게 위치시키고 불응시간이 1%이하가 됨을 확인한 후 축방향 중심에서 바깥방향으로 39 mm까지 (0.5 mm간격) 이동시키면서 각 4분간 PET 영상을 얻었다. 총동시계수에서 지연계수를 빼고 방사선 붕괴를 보정한 후 민감도를 계산하였다. 지름 60 mm, 길이 150 mm의 원통형 팬텀을 제작하여 NECR과 산란분획을 7반감기 동안 각 20분씩 얻은 데이터로부터 계산하였다. 결과: FBP로 재구성한 영상의 공간분해능은 횡단면 중심에서 각각 1.86 mm(반경 방향), 1.95 mm(접선방향), 1.95 mm(축방향)이었으며 중심에서 2 cm 벗어난 지점에서 각각 2.54 mm, 2.8 mm, 1.61 mm이었다. OSEM 영상의 공간분해능은 중심에서 각각 1.44 mm, 1.36 mm, 1.61 mm이었으며 중심에서 2 cm 벗어난 지점에서 각각 1.86 mm, 2.29 mm, 2.88 mm이었다. 민감도는 축방향 중심에서 2.36%, 축방향 시야길이의 1/4인 18.5 mm 지점에서 2.09%이었다. 산란분획은 20%이었으며, 최대 NECR은 242 kBq/mL에서 66.4 kcps이었다. 생쥐와 백서, 그리고 고양이의 뇌영상을 획득하여 영상의 품질을 확인하였다. 결론: 국내에 설치된 microPET R4의 공간분해능 및 민감도는 기존에 알려진 값들과 거의 유사하였으며, 소동물 PET 영상을 위하여 적합한 것으로 보인다.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Flight Model Development of the MIRIS, the Main Payload of STSAT-3

  • 한원용;이대희;박영식;정웅섭;문봉곤;박귀종;박성준;표정현;이덕행;남욱원;박장현;선광일;양순철;박종오;이승우;이명목
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.65.1-65.1
    • /
    • 2012
  • MIRIS (Multipurpose Infra-Red Imaging System) is the first Korean Infrared Space Telescope developed by KASI (Korea Astronomy and Space Science Institute), and is the main payload of STSAT-3 (Science and Technology Satellite-3). The FM (fight model) of MIRIS has been recently completed, and various performance tests have been made to measure system parameters such as readout noise, system gain, linearity, and dark current. Final thermal-vacumm test of the MIRIS and the vibration test of the electronics box have been performed. Band response tests showed good agreement with the initial design requirements. No significant dark difference was measured within the expected temperature variation range during observation in orbit. Using Pa-alpha band from a uniform source, the readout noise and system gain were measured by mean variance test. To obtain uniform flat image, flat fielding tests were made for each band, and the data will be compared to that obtained in orbit for calibration. The final version of MIRIS FM will be delivered in March, and it will be integrated into the satellite system for the AIT (Assembly Integration, Test) procedure. The launch of MIRIS is expected in November 2012.

  • PDF

밀리미터파 라디오미터를 이용한 인체의 내부 밝기온도 측정에 관한 연구 (Study on the Brightness Temperature Measurement in the Human Body Using Millimeter-wave Radiometer)

  • 정민규;김태훈;나승욱
    • 전자공학회논문지
    • /
    • 제53권5호
    • /
    • pp.163-167
    • /
    • 2016
  • 본 논문은 밀리미터파 라디오미터를 이용한 의료응용의 한 분야인 인체 내부의 밝기온도 측정에 관한 연구이다. 밀리미터파 대역 중에서 Ka - band의 주파수 영역에서 동작하는 렌즈, 직접 검출 수신기, 캘리브레이션 소스 등을 설계 제작하여 라디오미터 시스템을 구성하였다. 밀리미터파 렌즈 초점에 수신안테나를 스캔하는 방식을 통하여 미약한 신호를 수신하였으며, 렌즈 수차를 감소시키기 위해 광선 추적 방법을 사용하여 비구면 렌즈를 설계 하였다. 직접 검출 수신기는 Dicke 타입 수신기 형태로 설계되었으며, 제작된 수신기의 잡음지수는 3.3 dB, 온도감도는 0.1 K으로 측정되었다. 라디오미터의 수신기 교정은 밀리미터파 대역에서 사용가능한 새로운 형태의 블랙바디(Black body)를 제작하여 물체의 등가 잡음온도와 출력전압의 관계를 도출하였다. 제작된 시스템을 이용하여 1.7 m 거리에서 인체의 상반신을 측정하여 약 $38^{\circ}$[C]의 밝기온도를 측정하였다. 적외선 영상과 라디오미터 영상의 비교를 통해 상반신의 밝기온도 영상을 통하여 밀리미터파 라디오미터의 의료응용 가능성을 제시하였다.

프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구 (Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System)

  • 손준영;최성훈;이동훈;김희중
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.111-118
    • /
    • 2019
  • 흉부 디지털 단층영상합성장치는 기존 DR의 낮은 깊이 해상도, CT의 높은 피폭선량 문제를 해결할 수 있는 획기적인 영상장치로 대두되고 있다. 그러나 제한된 스캔 각도로 인해 프로젝션이 X 선 소스 동작 방향으로 흉부를 완전히 포함 할 수 없어 재구성 된 슬라이스의 위, 아래 방향 경계를 따라 강도의 불연속성이 발생하게 되는데 이러한 현상을 잘림 아티팩트 (Truncation artifact)라고 한다. 이 연구의 목적은 가중 정규화 접근법을 사용하여 잘림 아티팩트를 줄이고 리스템에서 개발한 프로토 타입 흉부 디지털 단층영상합성장치 시스템에 대한 이 접근법의 성능을 평가하는 것이다. 이 시스템의 source-to-image distance는 1100 mm 이고 X 선원의 회전 중심은 검출기 표면에서 100mm 위로 설정되었다. LUNGMAN 팬텀을 사용하여 ${\pm}20^{\circ}$의 투영 뷰를 $1^{\circ}$ 간격으로 41장을 얻은 후, filtered back projection 알고리즘으로 재구성했다. 정량적 평가를 위하여 시뮬레이션을 이용하여 기준영상을 재구성 후 peak signal to noise ratio와 structure similarity index 값을 평가하였으며 실제 실험 데이터를 이용하여 mean value of specific direction 값을 평가하였다. 시뮬레이션 결과로 아티팩트 보정 전 일반적인 filtered back projection 알고리즘으로 재구성 한 영상과 비교하여 peak signal to noise ratio값과 structure similarity index값 모두 각각 증가하였으며, 실제 실험 재구성 영상의 mean value of specific direction 결과는 아티팩트의 영향이 감소됨을 확인할 수 있었다. 결론적으로, 가중 정규화 방법은 잘림 아티팩트를 줄임으로써 진단의 어려움을 발생시키는 가능성을 개선시킬 수 있는 방법으로 사료된다.

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.