• Title/Summary/Keyword: Noise isolation

Search Result 444, Processing Time 0.023 seconds

A Study on the Signal Processing and Robust Control for a 3-DOF Active Vibration Isolator (3자유도 능동형 제진 시스템을 위한 신호처리 및 강인제어에 관한 연구)

  • Moon, Jun-Hee;Kim, Hwa-Soo;Pahk, Heui-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.153-156
    • /
    • 2006
  • The vibration isolation system is a system that attenuates the vibration transmitted from surroundings by using external energy supply like electricity and feedback and/or feedforward functions. Such a system needs stiff structure to make precise positioning without ripple within a certain bandwidth. So, a horizontal and rotary arrangement of the actuation module is suggested by using lever linkage. Modeling and kinematic formulation are completed and system identification is accomplished to tune the design variables accurately. The vibration isolation control is performed by mu-synthesis with the uncertainties in design variables. Low frequency signal enhancement circuit and saturation proof integration algorithm are devised to use seismic sensors for displacement control. This overall system shows good disturbance rejection performance.

  • PDF

Optimal Design of Vibration Isolation System in Optical Disc Drives (광디스크 드라이브의 방진계 최적설계)

  • 이은경;이기성;장헌탁;임경화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.961-966
    • /
    • 2001
  • The schematic design process is formulated to develop the vibroisolating rubber mount in optical disc drives. The dynamic model of vibration isolation system is established by using a rigid body with 6 degree of freedom and linear springs with damping property. Considering the practical vibration condition of DVDP(Digital Versatile Disk Player), the required properties of vibroisolating rubber mounts are investigated. Also finite element model of a vibroisolating rubber mount is used to obtain shape design concept and identify the characteristics of a rubber mount which satisfies the required properties from previous design stage. Finally the evaluation method of dynamic properties of vibroisolating rubber mounts is established by utilizing modal test method. Based on the developed process, vibroisolating rubber mounts with a good performance have been developed.

  • PDF

A Study on the Optimum Layout Design of Resilient Mounts for Shock & Vibration Isolation (충격/진동 절연을 위한 탄성마운트의 최적 배치설계)

  • 박주현;정정훈;김기화;조대승;김병현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.755-760
    • /
    • 2001
  • Major equipment of combat vessels normally require the shock and vibration isolation to maintain its performance against environments of severe vibration and shock. In this paper, an optimal layout design method of resilient mounts for shock and vibration isolation is presented using simulated annealing optimization method. The reference levels of vibration and shock to isolate shipboard equipment are determined from the MIL-STD-167-1 and MIL-S-901 specifications. Through the numerical application, the validity of the presented method is investigated.

  • PDF

A Study on the Dynamic Characteristics of S/C Shipping Container Isolation System (다목적 실용위성2호의 운송 콘테이너 개발)

  • 우성현;김홍배;문상무;김영기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.933-939
    • /
    • 2001
  • A Satellite shipping container must afford the satellite a relatively benign thermal, vibration, and particle environment that is oblivious to the extreme temperatures, sand, dust, vibrations and shocks that can accompany the transportation. In this study, we have designed a vibration isolation system of a spacecraft container that will be used to transport a satellite called KOMPSAT (KOrea Multi-Purpose SATellite) -2 from KARI (Korea Aerospace Research Institute) Taejon to its launch site. To identify the dynamic characteristics of the system, a 1/3-scaled mockup of the container was developed. A large electro-magnetic shaker (Max. 240 KN) was used to excite the mockup, and vibration signals from 20 points were collected for modal tests. Numerical simulations through CATIA 3D Modeling were performed to identify the behavior of isolation springs. The results showed that a simplified model predicts the behavior in a reasonable accuracy. Moreover, the model guides us how to design a full-scaled satellite-shipping container.

  • PDF

Power Flow Approach in Vibration Isolations (파워흐름 개념을 이용한 진동 절연법)

  • Lee, Ho-Jung;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.170-177
    • /
    • 2004
  • A single degree of freedom system and transmissibility are key concepts in many problems of vibration isolation. In order to apply this approach, however, several assumptions must be satisfied, which are often not realistic. In this paper, an approach using vibration power flow is introduced to deal with vibration isolations in a more practical way. Procedures of this approach and some results of research are presented. Difficulties in this method are also discussed.

  • PDF

A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets (차음시트의 음향투과손실 측정에 관한 연구)

  • Lee, Dong-Hoon;Kang, Moon;Lee, Ju-Weon;Jung, Gab-Cheol;Kwon, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

Study on the Effect of Vibration Reduction Characteristics of Floors on the Inside Running Noise in Railway Vehicles (전동차 바닥구조의 진동절연특성이 실내소음에 미치는 영향)

  • Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.908-912
    • /
    • 2008
  • Structure-borne noise is known to dominate internal running noise levels in open field. In this paper vibration isolation characteristics of floors are investigated to see their effect on the internal running noise. By using the analysis and test results of test specimen of small size, internal running noise level of complete train is estimated. Analysis results show that soft rubber as a vibration isolator has the most favorable effect on the inside running noise.

  • PDF

An Experimental Analysis of the Structure-Borne Noise Reduction on Electrical Equipment (전자장비 구조기인소음 저감방안의 실험적 검토)

  • Lee, Seong-Hyun;Seo, Yun-Ho;Kim, Won-Hyoung;Choi, Young-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.111-117
    • /
    • 2014
  • In this paper, the structure-borne noise reduction on electrical equipment is discussed by the experimental analysis. The water cooling system in electrical equipment is the only noise source, so the mock-up was made to measure noise characteristics. Effects of power supply, stiffness, isolation of noise source and natural frequency determined by resilient mounts are investigated using the mock-up. The console prototype was made referring to noise reduction technique by the mock-up. The structure-borne noise level of a console prototype was measured and some experiments to reduce the noise was undertaken. The $1^{st}$ and $4^{th}$ harmonics of operating frequency of cooling fans causes highest structure-borne noise levels. The control of operating speeds of several DC cooling fan groups was tried. Also types and installation layouts of resilient mounts were investigated. To reduce structure-borne noise, followings can be applied: increase of stiffness, isolation of source, decrease of natural frequency of mount, combination of operating speed of fans, selection of mounts, and so on.

Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation

  • Jiang, Guoping;Tao, Weijun
    • Structural Engineering and Mechanics
    • /
    • v.51 no.4
    • /
    • pp.643-650
    • /
    • 2014
  • A chaotic vibration isolation system is designed according to the chaotic vibration theory in this paper. The strong nonlinearity is generated by the system. Line spectra in the radiated noise maybe easily detected caused by marine vessels. It is Important to reduce the line spectra by improving the acoustic stealth of marine vessels. A multi-degree-freedom (MDF) nonlinear vibration isolation system (NVIS) system is setup by the experiment and finite element method. The model is established with finite element method. The results show that the behavior of the device gradually varies from period bifurcation into chaotic state and the line spectrum is changed from single spectral structure into broadband spectral structure. It is concluded that chaotic vibration isolation is preferable contrasted on line spectra isolation.

PZT stack actuator-based hybrid mount system for mitigating micro-vibration of vibration isolation table (제진 테이블의 미진동 저감을 위한 PZT stack 가력기 기반 복합형 마운트 시스템)

  • Moon, Yeong-Jong;Jang, Dong-Doo;Moon, Seok-Jun;Choi, Sang-Min;Jung, Hyung-Jo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.292-298
    • /
    • 2009
  • This paper investigates the control performance of the proposed hybrid mount system for vibration isolation table. The hybrid mount system consists of an air spring as a passive device and a PZT stack actuator as an active device in series. The feasibility of the PZT stack actuator as an active actuator was examined through the simple experiments. After that, a series of numerical simulations were carried out to evaluate the control performance of the proposed hybrid mount system. The equations of motion of the table with a set of hybrid mount systems consisting of four devices are derived. The air spring is considered as a 1 spring and 1 dashpot elements, and PID control algorithm is adopted to estimate the control force. The results of the numerical simulations presents that the proposed hybrid mount system could be the promising control system for vibration isolation table.

  • PDF