• Title/Summary/Keyword: Noise insulation

검색결과 449건 처리시간 0.032초

청감실험을 이용한 건축설비소음의 등급화 (Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment)

  • 유희종;정철운;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.488-492
    • /
    • 2007
  • Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

  • PDF

민항기와 군용기가 혼합된 공항 주변지역의 항공기 소음에 대한 거주자 반응 (Subjective Response for the Aircraft Noise in the Region around Airport mixed with Commercial and Military Aircrafts)

  • 백형배;박현구;김선우
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.99-106
    • /
    • 2009
  • This study aims to survey the acoustical environment in the region around airport where there are various transportation noises such as aircraft noise, railway noise and traffic noise, and to analyze the subjective response on the noise to the people who live in house or work in office nearby airport. Measurement and subjective response evaluation were carried out at the same time and outdoor noise level was measured all day long to calculate one day results such as average Leq or one day WECPNL etc. The results showed that the military aircraft produces very high level comparing with commercial aircraft, for instance the sound level of commercial outdoor was lower than that of military aircraft indoor. Double and triple window were more effective for controlling the noise than single window, which showed the possibility of sound insulation treatment by installing windows having higher sound insulation performance. Finally the subjective response was resulted that the most annoying noise is from aircraft and counterplan they hope is 'airport moving out'. Leq 65 dB(A), the criteria value of sound insulation treatment, was corresponding to the subjective response of median annoyance '4' out of 7th scale.

파워기반 소음감소 기법을 이용한 준중형 해치백 후석 고주파성 로드노이즈 전달특성 연구 (A study on the characteristics of high frequency road noise transmission at the rear seat of a hatch back compact car using PBNR (Power Based Noise Reduction) method)

  • 이종현;조세현;이주완;이철현;양정민
    • 한국음향학회지
    • /
    • 제37권4호
    • /
    • pp.248-255
    • /
    • 2018
  • 세단 타입에 비해 해치백 타입의 차량은 실링구조 확보에 어려움이 있기 때문에 후석에서 느껴지는 차폐성능이 열세한 것으로 알려져 있다. 차량의 차폐감 확보를 위해 강건한 실링 시스템과 충분한 흡음/차음 성능이 요구되지만 준중형 이하 세그먼트에서는 원가, 중량의 제약으로 인해 충분한 흡차음 사양 적용에 제한을 받고있어 효율적인 흡차음 사양의 적용이 요구되고 있는 실정이다. 본 연구에서는 정량적인 측정과 비교, 분석이 가능한 파워기반 소음감소(Power Based Noise Reduction, PBNR) 기반의 차음 윈도우 평가를 통해 준중형 해치백 차량의 후석 소음원의 전달 경로를 분석하고 후석 차폐성능 확보를 위한 흡차음 대안을 제시하였다.

건설공사장 가설방음벽의 음향 특성 (Acoustic Properties of Temporary Noise Barriers on Construction Site)

  • 정진연;임정빈;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제20권2호
    • /
    • pp.191-198
    • /
    • 2010
  • The noise by the construction activities is one of the main issues in Korea. To prevent the noise from construction site, construction company installs temporary noise barriers along the construction site boundary. Normally sound insulation performance ($R_w$) of the temporary noise barriers made by metal or plastic is between 18 and 31 dB and metallic noise barriers are around 5 dB higher than plastic noise barriers. Sound absorption performance (NRC) of the temporary noise barriers are between 0.20 and 0.59 so it's difficult to characterize their acoustic performance. In this study, it has founded that sound insulation performance of the temporary noise barrier has been improved about 3dB by stick the high density acoustic sheet and insertion loss of noise barrier is getting increased as the source and receiver approached the temporary noise barriers.

고속철도구간 방음벽 제진재 시험제작 및 성능평가에 관한 연구 (A Study on Sample manufacturing and Performance Evaluation for Vibration Insulation Material of Noise Barrier for High-Speed Railway)

  • 김순철;강정옥;한광섭;전병찬;한종문
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.522-529
    • /
    • 2005
  • The commercial service of KTX from April 1st 2004 has realized that whole country has shrunk into half-day life zone and it opened the times of speed. However, some technical problems unexpected before service have been raised and, among them, the noise generation at train passing was claimed by the residents living nearby the track and it is often publicized by the broadcastings and newspapers. In case where the residential area is close to the track, the installation of noise barrier at trackside is the general measures for noise reduction on bridge section and earthwork section. In case of KTX project, such measures were actually taken without any exception; however, the noise level is still high. In this study, analysis for the reason of higher noise level in spite of which the noise barriers are being installed was carried out, the sample of insulation material effective for noise barrier was manufactured and the performance of the insulation material was evaluated to verify its effectiveness

  • PDF

바닥충격음 관련 국내 실험실 현황 및 고찰 (Review of laboratory test facilities for measuring impact sound insulation in Korea.)

  • 장길수;정갑철;김재수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.234-238
    • /
    • 2001
  • This study aims to review the present conditions of domestic laboratory test facilities for measuring impact sound insulation. The result will be useful to establish the new Korean Standard to coincide with ISO 140-6.

  • PDF

실험실에서의 발코니창호 차음성능 평가 (The estimation of Sound insulation performance by the balcony windows in the reverberant room and anechoic room)

  • 김태희;신일섭;조창근;오진균;김남욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.956-959
    • /
    • 2007
  • The extension of a road system result from construction of the builling near the noise source as the roads, railroads. Many people who have a living space near the road are damaged by the noise generated the road system. Therefore, the damage will be reduced by the appropriate measure like putting some distance between receiver and source. The windows are weak among the building materials. But mainly we uses the windows as building exterior materials. So the sound insulation of the balcony windows was measured and compared.

  • PDF

외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과 (Improvement of sound insulation performance of windows according to the specifications of the external electric blinds)

  • 강민우;이희동;오양기
    • 한국음향학회지
    • /
    • 제41권6호
    • /
    • pp.621-628
    • /
    • 2022
  • 도로교통 소음이나 항공기 소음 등의 건물 외부소음을 저감하기 위한 가장 현실적인 방안은 각 건물의 발코니와 창호, 외벽 등 수음점에서의 차음성능을 강화하는 것이다. 그러나 아직 건물 외부의 차양장치가 광범위하게 사용되지 않고 있는 현실에 비추어 루버나 블라인드 등의 창호 외부장치를 활용하는 차음성능 개선 연구는 많지 않다. 특히 외장형 블라인드는 아침-저녁의 강한 일사의 유입을 건물 외부에서 차단하는 차광 효과 뿐 아니라 출퇴근 시간대에 발생하는 피크 소음을 차단하는 차음 효과도 동시에 목표할 수 있다. 이 연구에서는 가장 효율적인 창호 외부 차양장치의 하나인 외부 전동블라인드(External Electric Blind, EEB)를 활용하여 외부소음에 대한 차음성능을 개선하고자 하는 연구를 수행하였다. 차광 용도로 개발된 외부 전동블라인드의 구성을 변화시켜가면서 다양한 차음성능 실험을 수행하였다. 이를 통해 일반 창호의 저감 성능 대비 외부 전동블라인드를 설치함으로써 6 dB의 추가 차음성능을 얻을 수 있음을 검증하였다.

AZ31 마그네슘합금의 자동차 Hood Panel적용에 따른 주파수응답 및 소음 특성의 변화 (Noise Characteristics and Frequency Response Function on Implementation of AZ31 Magnesium Alloy to Automobile Hood Panel)

  • 이충도;여동훈
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.139-146
    • /
    • 2011
  • In present study, it aims to compare the noise and vibration characteristics between magnesium alloy and steel hood panel. The AZ31 magnesium hood panel was fabricated through warm forming process, and the noise and vibration characteristics between both hood panels was compared through the measurement of engine radiation noise and transmission loss, as well as FRF on modal analysis. The sound insulation performance of magnesium alloy was wholly superior to that of steel hood panel, even though the transmission loss of magnesium alloy is lower than that of steel due to mass effect primarily. The FRF characteristics on modal analysis indicates that the resonance frequency of magnesium hood panel is remarkably increased to higher value than that of steel hood panel. The radiation and interior noise of magnesium panel even without acoustic hood insulation were remarkably lower than those of steel hood panel with acoustic insulation, in particular, at a range below 4,000 rpm.

복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구 (A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.