• 제목/요약/키워드: Noise Reduction Barrier

검색결과 93건 처리시간 0.025초

유전자 알고리즘을 이용한 음향 간섭 모델 최적화 설계 (The Study on the Optimum Design of Acoustic Interference Model by Genetic Algorithm)

  • 이재환;장강석
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.18-23
    • /
    • 2003
  • The Objective of this research is to find the optimal design of the Noise Reduction Interference Model (NRIM) which is recently invented. Without optimization, the NRIM has been successful to reduce the urban noise induced by trains and automobiles. While it is used with the barrier on the road, there is a strong desire to reduce noise more. Yet the only remedy is to make the barrier higher with cost increase. Therefore, the optimal design is necessary to reduce noise while maintaining the barrier height. More efficient Genetic Algorithm is used to find the optimal shape of NRIM with the reduction of noise lever up to 15 dB. also BEM is used to verify the optimal design results.

  • PDF

신도시 친환경 주거단지조성을 위한 소음저감 대책방안 (Noise Reduction Method for Environment Friendly Housing Estate)

  • 김흥식;주문기;주시웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.535-541
    • /
    • 2004
  • For housing estate of a new administrative capital city, Noise reduction method is a important design factor. As measuring a noise level of traffic noise according to separation from road, it can be created a quite housing estate. Analyzing of merits and demerits in sound barrier walls and tunnels can be proposed environment friendly soundproofing facilities. Number of measurement was performed to know what kind of layout of housing estate is good for noise reduction. Through this measurement, ㄷ shaped layout or parallel layout has the advantage of sound insulation rather than right angled layout. In this case (ㄷ shaped layout or parallel layout) buildings neighboring to the road should be designed to insulate sound. Evergreen trees should be planted between housing estate and road more than 30m (at least 7~8m) in order to reduce noise and have masking effects. If broad-leaved trees are planted more than 30m, approximately 10dB noise is reduced and 2~4dB if 7~8m. Roads in the estate should be designed considering pedestrians first, and special roads for moving and ambulance should be designed as skew road, if possible. The result shows that 15$^{\circ}$-sloped‘S’road reduces 1~2dB noise and 30$^{\circ}$-sloped road reduces 4~7dB. If noise barrier is inevitably installed, it should be designed to go well wit neighboring environment so as to install Environment Friendly Noise Barrier using materials and trees including wood and soil. Through this study the results are used to guideline for construction of environment friendly housing estate

  • PDF

방음벽 및 저소음 포장에 대한 비용/편익 분석 (Cost-benefit Analysis for Noise Barrier and Low Noise Pavement)

  • 조윤희;손정곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.502-507
    • /
    • 2011
  • A study on environmental noise hasn't fully researched yet. As society has developed and the quality of life has improved, people started to show a concern about an environmental noise. To ensure a economic feasibility of countermeasures of noise, it is necessary to apply a cost-benefit analysis on choosing optimum measurements. In this study, we addressed the estimation method of the environmental noise value and several domestic and oversea case studies. We also estimate economic value of noise reduction level which is gained from applying noise reduction measurements.

  • PDF

방음벽 안전을 위한 기준 조사 및 분석 (Investigation and Analysis of Regulations for the Safety of the Noise Barrier)

  • 허영;김흥식
    • 한국소음진동공학회논문집
    • /
    • 제13권9호
    • /
    • pp.730-734
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

모형실험을 통한 식생형 방음벽의 소음저감 효과 분석 (An analyses of the noise reduction effect of vegetation noise barrier using scaled model experiments)

  • 한찬훈;홍성신
    • 한국음향학회지
    • /
    • 제35권3호
    • /
    • pp.223-233
    • /
    • 2016
  • 공동주택단지 및 학교 및 근린시설의 경계방음벽으로 제시한 식생형 방음벽을 설계하고 소음감쇠성능실험을 실시하였다. 본 논문에서 제시한 식생형 방음벽은 일정한 형태의 유닛을 방음벽 형태의 구조물에 걸이식으로 적층하여 구성된 것으로서, 유닛내부에는 식재 및 토양을 포함하고 있다. 이 방음벽의 음향적인 장점은 토양 및 식재를 이용한 흡음뿐만 아니라 확산형상의 방음벽에서 표면 확산으로 인해 음에너지가 분산되어 소음을 저감할 수 있을 것으로 예상된다. 먼저 1/10 축소모형 실험을 통해 소음감쇠성능에 가장 적합한 방음벽 유닛의 크기를 조사하였으며, 설계된 도면에 따라 1/2축척의 식생형 방음벽을 실제높이 2 m, 길이 5 m로 제작하여 소음감쇠실험을 진행하였다. 식물을 담을 수 있는 총 1,137개의 식생블록은 약 $10{\times}10{\times}9cm$ 크기로 합성목재를 활용해 제작하였으며 이 블록들을 방음벽에 설치하여 자립형 구조를 가진 식생형 방음벽을 완성하였다. 연구결과, 평면형 방음벽보다 블록식 방음벽이 약 7 dB 더 높은 삽입손실을 나타냈으며, 식생블록의 크기는 삽입손실효과가 큰 $20{\times}20cm$의 크기가 적정한 것으로 나타났다.

건설공사장 가설방음벽의 음향 특성 (Acoustic Properties of Temporary Noise Barriers on Construction Site)

  • 정진연;임정빈;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제20권2호
    • /
    • pp.191-198
    • /
    • 2010
  • The noise by the construction activities is one of the main issues in Korea. To prevent the noise from construction site, construction company installs temporary noise barriers along the construction site boundary. Normally sound insulation performance ($R_w$) of the temporary noise barriers made by metal or plastic is between 18 and 31 dB and metallic noise barriers are around 5 dB higher than plastic noise barriers. Sound absorption performance (NRC) of the temporary noise barriers are between 0.20 and 0.59 so it's difficult to characterize their acoustic performance. In this study, it has founded that sound insulation performance of the temporary noise barrier has been improved about 3dB by stick the high density acoustic sheet and insertion loss of noise barrier is getting increased as the source and receiver approached the temporary noise barriers.

통기형 방음벽의 음향감쇠 특성에 대한 실험적 분석 (An experimental analysis of the sound reduction characteristics of air transparent noise barriers)

  • 박찬재;지용수;임재현;한찬훈
    • 한국음향학회지
    • /
    • 제35권6호
    • /
    • pp.491-500
    • /
    • 2016
  • 본 논문에서는 공기를 통과시켜 풍압을 저감하면서 소음을 제어할 수 있는 새로운 개념의 방음벽의 음향감쇠 특성을 분석하였다. 통기형 방음벽의 소음저감 특성을 조사하기 위하여 우선 개구부의 크기 및 공명기의 체적 등을 변화시켜 총 17가지 방음벽 모델의 음향감쇠계수를 측정하였다. 실험결과 공명기의 체적과 개구부의 면적에 따라 음향감쇠계수 값이 달라지고 있으며, 목표 주파수대역(400 ~ 1250 Hz)에서 단일 방음벽보다 이중 방음벽의 음향감쇠계수가 더 높게 나타났다. 이를 통해 개구부 및 공명기의 물리적 특성이 통기형 방음벽의 차음특성에 영향을 미친다는 점을 밝혀냈다.

단일수치 평가방법에 따른 방음벽의 흡음성능 고찰 (Sound Absorption Performance of Noise Barrier According to Single Number Rating Methods)

  • 김용희;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.243-250
    • /
    • 2017
  • In this study, single number rating methods of sound absorption coefficients are discussed. After that the sound absorption performance of noise barriers which are classified by Korea Standard are analyzed according to several standards. The existing rating methods such as NRC (noise reduction coefficient), SAA (sound absorption average) or ${\alpha}_w$ (weighted sound absorption coefficient) from ASTM C423, KS F 3505 and ISO 11654 are introduced. The sound absorption performance of noise barrier is evaluated to compare NRC and ${\alpha}_w$ value. When the value is over 0.6 there are large variance between NRC and ${\alpha}_w$ value. As results, it is needed to unify single number rating methods of sound absorption coefficients for Korean standards on sound absorbing materials.

방음벽 안전을 위한 기준 조사 및 분석 (Investigation and Analysis of Regulations for the Safety of the Sound Barrier)

  • 허영;김홍식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.219-223
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

  • PDF

능동방음벽 시스템의 제어 음원 위치 선정에 미치는 최적화 기법 성능 비교 연구 (A Study on the Performance Comparison of Optimization Techniques on the Selection of Control Source Positions in an Active Noise Barrier System)

  • 임형진;백광현
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.911-917
    • /
    • 2005
  • There were many attempts to reduce noise behind the noise barrier using active control techniques. Omoto(1993) Shao(1997) and Yang(2001) tried to actively control the diffracted noise behind the barrier and main concerns were about the arrangement methods for the control sources. Baek (2004) tried to get better results using the simulated annealing method and the sequential searching technique. The main goal of this study is to develop and compare the performance of several optimization techniques including those mentioned above, hybrid version of simulated annealing and genetic algorithm for the optimal control source positions of active noise barrier system. The simulation results show fairly similar performance lot the small size of searching problem. However, as the number of control sources are increased, the performance of simulated annealing algorithm and genetic algorithm are better than the others. Simulations are also made to show the performance of the selected optimal control source positions not only at the receiver position but at the surrounding volume of the receiver position and plotted the noise reduction level in 3-D.