• Title/Summary/Keyword: Noise Abatement

Search Result 47, Processing Time 0.023 seconds

Prediction of the Effect of Quiet Pavement on Reducing Barrier Height (저소음 포장도로 시공에 따른 방음벽 높이 저감효과 예측)

  • Yang, Hong-Seok;Cho, Hyun-Min;Jeong, Jong-Seok;Kim, Myung-Jun
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.31-37
    • /
    • 2016
  • PURPOSES : The purpose of this study is to evaluate the effect of the quiet pavement on reducing a barrier height by using a prediction tool called SoundPLAN. METHODS : Firstly, the prediction was carried out to evaluate the difference in the maximum noise level at a building facade between the normal and the quiet pavements without a barrier. After calculating the noise reduction effect by the quiet pavement, a comparable barrier height to obtain the same noise reduction effect with it was predicted according to designable factors including road-building distance(10 m, 20 m, 40 m) and road-barrier distance(5 m, 10 m, 20 m, 30 m). RESULTS : The result showed that within the considered designable factors, the maximum barrier height was 37 m, 52 m, and 55 m to have the same noise reduction effect by the quiet pavement reducing 1 dBA, 3 dBA, and 5 dBA, respectively. It was evaluated that the barrier height increased with the increase of the road-building and road-barrier distances. To simulate the real situation in urban areas and to evaluate the combined effect of the normal/quiet pavement and barrier, the barrier height was fixed as 6 m. It was predicted that the noise level would reduce to as low as 0.2 dBA by the combination of normal pavement and barrier. On the other hand, the combination of the quiet pavement and barrier reduced 1.2 dBA, 3.2 dBA, and 5.2 dBA, respectively, for quiet pavement reducing 1 dBA, 3 dBA, and 5 dBA. CONCLUSIONS : A guideline needs to be suggested to select appropriate noise abatement schemes by considering factors such as the roadbuilding and road-barrier distances.

Designing isolation system for Engine/Compressor Assembly of GAS Driven Heat Pump (가스 엔진 구동 열펌프 실외기 엔진/압축기 진동 절연 설계)

  • Lenchine Valeri V.;Ko, Hong-Seok;Joo, Jae-Man;Oh, Sang-Kyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1128-1133
    • /
    • 2003
  • A gas driven heat pump (GHP) core design comprises internal combustion engine, compressors incorporated to a cooling/heating system, rubber mountings and belt transmissions. Main excitation farces are generated by an engine, compressors themselves and belt fluctuation. It leads to high vibration level of the mount that can cause damage of GHP elements. Therefore an appropriate design of the mounting system is crucial in terms of reliability and vibration reduction. In this paper oscillation of the engine mount is explored both experimentally and analytically. Experimental analysis of natural frequencies and operational frequency response of the GHP engine mounting system enables to create simplified model for numerical and analytical investigations. It is worked out criteria f3r vibration abatement of the isolated structure. Influence of bracket stiffness between engine and compressors, suspension locations and damper performance is investigated. Ways to reduce excitation forces and improve dynamic performance of the engine-compressor mounting system are considered from these analyses. Implementation of the proposed approach permits to choose appropriate rubber mountings and their location as well as joining elements design A phase matching technique can be employed to control forces from main exciters. It enables to changing vibration response of the structure by control of natural modes contribution. Proposed changes lead to significant vibration reduction and can be easily utilized in engineering practice.

  • PDF

Comparative analysis of the fuel consumption during Descent Flight (강하비행시의 연료소모량 비교분석)

  • Shin, Dai-Won;Kim, Yong-Seok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.2
    • /
    • pp.58-63
    • /
    • 2011
  • A Continuous Descent Approach(CDA) is defined as a simple, cost-effective, noise and emission abatement technique for any powered aircraft on approach. CDA also can be optimised within energy, speed and safety constraints by avoiding unnecessary flap, air brake and engine thrust. This study includes comparison on fuel consumption between Continuous Descent type and Step Down type by using flight data. In particular, we investigated fuel flow per hour, calibrated airspeed and pressure altitude for all flight time. During descent flight, the fuel consumption of Continuous Descent type was less than the fuel consumption of Step Down type.

The Extreme Low Speed Motor Observer and Brake Torque Control Technologies (극 저속 전동기용 관측기 및 제동 토크 제어 기술)

  • Kim, Young-Choon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.363-368
    • /
    • 2013
  • This paper relates to the electric braking, the permanent magnet synchronous motor vector control is suspended until the applied, and propose a new scheme by the controller in the observer to estimate the position and velocity using the Resolver speed detector. In addition, as a way to control the speed by braking torque at low speed, the pole of a stop just before the stop electrical braking. As a result, noise and dust abatement, consumption, reduction of the brake shoe increase the maintainability of comfort and energy use, enhances the effect of EMU performance improved sikyeoteum could see.

Reduction Method of Acoustic Vibrating Plate Using Piezo Electric Material (압전 소자를 이용한 음향 진동 박판에 대한 제어 기법)

  • Jung, Do-Hee;Park, Seen-Ok;Kim, Woo-Young;Lee, Sang-Kee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.777-784
    • /
    • 2003
  • Acoustic response control of a corner-pinned plate using piezoelectric wafers was studied, both theoretically and experimentally Three different sizes of aluminum alloy plates were used and available ball joints were employed to hold the plate at the four corners. The plate with the largest aspect ratio showed the largest and most clear responses to the acoustic excitation in the range of frequencies (0∼200 Hz), and sound pressure levels (80∼100 dB) as predicted. The reduction of the acoustic response of the plate by piezoelectric actuator was very significant, more than expected, but abatement of the sound transmission through the plate was only slightly altered by the piezoelectric actuator. This work is an original work extending earlier work with doors excited by acoustic fields. The important difference is the used of ball joints to simulate the joints.

A Study on Use Satisfaction and Image Evaluation of User through Post Occupancy Evaluation in Urban Park - On the 2·28 Memorial Park in Daegu - (도심공원 이용 후 평가를 통한 이용 만족도와 이미지 평가 - 대구 2·28기념중앙공원을 대상으로 -)

  • Koo, Min-Ah;Eom, Boong-Hoon;Han, Ye-Seo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.4
    • /
    • pp.11-20
    • /
    • 2018
  • This paper deals with Post Occupancy Evaluation (POE) of 2.28 Memorial Park in Daegu. The park is located in center of the city. The results and discussions could be used as basic data for urban park planning and design, in CBD. A questionnaire was conducted for 15 days from May 11, to May 26, 2016, and a sample group consisting of 230 on site users. The behavior, satisfaction, and preference of space image, were surveyed. The behavior analysis, satisfaction, and image evaluation questionnaire were derived using previous studies, and reliability, factor analysis and multiple regression analysis were conducted using SPSS. As a result, the items were very reliable, causal factors were extracted, and the variables that affect satisfaction and image preference were able to be identified. In the 2.28 Memorial Park, user satisfaction and image evaluation value were very high in most items. As a result of the assessment, the green-water landscape factors and cleanness factors, which have the greatest influence on satisfaction and preference, should be continuously maintained. Due to the characteristics of the city center parks, the users of the parks also felt environmental problems in the urban areas, so the users assessed noise levels, plant species, and air quality at a low level. Therefore, to solve this, plans such as noise abatement and extension of green space should be ongoing.

A Study on Location and User Satisfaction of the Green Buffer Zone in Gwanggyo New Town (광교신도시 완충녹지의 입지와 이용만족도 연구)

  • Kim, Ju-Ok;Choi, Won-Bin;Shin, Ji-Hoon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.6
    • /
    • pp.21-33
    • /
    • 2017
  • The purpose of this study is to find out that it can be provided as a basic data to increase the satisfaction with users in the placement and creation of the Green Buffer Zone. In this study, the research was started on the Green Buffer Zone in Gwanggyo new town, which was rebuilt as the zone to use according to the change of legal installation standard of the zone. The subject of this study is the Green Buffer Zone in Gwanggyo new town, which is expected to be completed in step 4 of 2016. As a result of analysing the location and use characteristics of the Green Buffer Zone, the following conclusions were made. First of all, it is categorized into two categories by Buffering / disaster prevention type and land to use adjustment type. Second, the buffer space of commercial space and housing is satisfying, but in commercial space, there is a need for a cushioning function and housing spaces require improvements in the functioning of the landscape. Third, the function of the Green Buffer Zone resets to cushioning function, disaster prevention function, landscape function, utilization function. and The installation criteria are proposed to environmental pollution, noise abatement, and planting trees, etc. Lastly, the future utilization plan considering the location and use characteristics of the Green Buffer Zone is as follows. In the planning stage, preference is given to the characteristics of use of arranging green facility. It is necessary to manage the planned facilities as much as possible by changing them if necessary. Construction stage, it restrictively reflects landscaping facilities within the Green Buffer Zone function. After stage, This study will prioritize the target areas and select necessary areas and need to make efforts to prevent indiscriminate greenery encroachment.