• 제목/요약/키워드: No-load speed

검색결과 288건 처리시간 0.027초

A New-Generation Sensorless Vector Control Scheme for Induction Motor Drive

  • Shinnaka, Shinji
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.287-292
    • /
    • 1998
  • This paper presents some results of performance evaluation test via actual machines of a new hybrid vector control utilizing a new indirect orientation scheme and stable filter embedded direct orientation scheme for induction motors without speed or position sensor. It is shown through the test by 0.3(kW) and 3.7(kW) motors that the proposed sensorless vector control has the following high potentialities: 1) speed range is 0 to 600(rad/s) or more, 2) zero-speed command is accepted and settles the machines at a stable standstill with no vibration 3) it can make machines to track variable command of acceleration and deceleration $\pm$6,000(rad/s2), 4) it can make machines to drive directly load of at least 26 times larger inertia than that of the machine, 5) it can make machines to produce much larger torque than the rating in torque control mode even at standstill. The performance confirmed by the test is far away for previous schemes or sensorless drive apparatuses.

  • PDF

건축구조기준을 활용한 농가지도형 G형 비닐하우스의 풍하중 안전성 평가 (Evaluation of Wind load Safety for Single G-type Greenhouse Using Korean Design Standard)

  • 이우근;신경재
    • 한국농공학회논문집
    • /
    • 제66권1호
    • /
    • pp.39-48
    • /
    • 2024
  • Plastic greenhouses are simple structures consisting of lightweight materials such as steel pipes and polyvinyl chloride. However, serious damage occurs due to heavy winds and typhoon every year. To prevent a collapse of structural members, the Ministry of Agriculture and Rural Development has distributed plans and specifications for disaster-resistant standards. Despite these efforts, more than 50% of greenhouses still do not satisfy the disaster-resistant standards. Among the greenhouses that do not meet these standards, 85% are single-span greenhouses proposed 20 years ago. Consequently, there is a need to evaluate the safety of wind loads for the single-span greenhouse. Unfortunately, there are no design specifications for the greenhouses under wind loads. Therefore, a Korean design standard (KDS) has been utilized. KDS is defined with reference to wind speeds occurring once every 500 years, raising concerns about potential overdesign when considering the durability of plastic greenhouses. To address this, the modified wind load, considering the durability of the plastic greenhouse, was calculated, and a safety evaluation was conducted for sigle G-type plastic greenhouse. It was observed that the moment acting on the windward surface was substantial, and there was a risk of the foundation being pulled out if the basic wind speed exceeded 32 m/s. In terms of the combination strength ratio, it was less than 1.0 only on the leeward side when the basic wind speed was 24 m/s and 26 m/s. However, in all other cases, it exceeded 1.0, indicating an unsafe condition and highlighting the necessity for reinforcement.

An Energy Saving Scheme for Multilane-Based High-Speed Ethernet

  • Han, Kyeong-Eun;Yang, Choong-Reol;Kim, Kwangjoon;Kim, Sun-Me;Lee, Jonghyun
    • ETRI Journal
    • /
    • 제34권6호
    • /
    • pp.807-815
    • /
    • 2012
  • In this paper, we propose a scheme for partially dynamic lane control for energy saving in multilane-based high-speed Ethernet. In this scheme, among the given transmission lanes, at least one lane is always operating, and the remaining lanes are dynamically activated to alleviate the network performance in terms of queuing delay and packet loss in the range of acceptance. The number of active lanes is determined by the decision algorithm based on the information regarding traffic and queue status. The reconciliation sublayer adjusts the transmission lane with the updated number of lanes received from the algorithm, which guarantees no processing delay in the media access control layer, no overhead, and minimal delay of the exchanging control frames. The proposed scheme is simulated in terms of queuing delay, packet loss rate, lane changes, and energy saving using an OPNET simulator. Our results indicate that energy savings of around 55% (or, when the offered load is less than 0.25, a significant additional savings of up to 75%) can be obtained with a queuing delay of less than 1 ms, a packet loss of less than $10^{-4}$, and a control packet exchange time of less than $0.5{\mu}s$ in random traffic.

부분부하제어를 위한 스크류형 과급기 개발 (Development of a screw type super-charger for part load control)

  • 배재일;배신철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.353-358
    • /
    • 2001
  • Turbo-charging or Super-charging has been used to boost engine power for Gasoline Engine and Diesel Engine came to the world at the beginning of $20^{th}$ century. So far Turbo-Charger has enjoyed a high reputation in the charging filed for its technical advantages such as no demand of operation power from engine and an excellent charging effect in the event of a static operation at mid- and high engine speed. A mechanically driven Super-Charger, however, is now emerging in order to meet demands of the age of speed such as high engine power for a quick change of the driving mode - high engine torque even at low engine speed. Since Super-Charger needs driving power from engine, it cannot improve its relatively higher fuel consumption against that of Turbo-Charger. This negative point is still an obstacle to the wide use of Super-Charger. Super-Charger using Screw-type compressor which has already had a considerable base in air compressor market will fulfill this purpose of improving fuel consumption by minimizing operation power owing to no charging at idling or partially loading driving. This study aims to develop power control concept to achieve this minimization of operation power.

  • PDF

이동하중(移動荷重)과 축하중(軸荷重)이 작용(作用)하는 유연(柔軟)한 기초(基礎)위에 지지(支持)된 무한(無限)보의 휨모멘트 특성(特性) (Bending Moment Characteristics of Flexibly Supported Infinite Beam Subjected to an Axial Force and a Moving Load)

  • 홍동표;김광식
    • 대한토목학회논문집
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 1982
  • 이 연구(硏究)는 이동하중(移動荷重)과 축하중(軸荷重)이 작용(作用)하는 무한(無限)보에 휨모멘트를 해석(解析)하고 공진선도(共振線圖)를 나타낸다. 하중(荷重)과 함께 이동(移動)하는 좌표계(座標系)에서 정상해(定常解)를 구하였다. 지지(支持)된 기초(基礎)는 감쇠(減衰)를 포함하였고 축하중(軸荷重)과 감쇠(減衰)와 이동하중속도(移動荷重速度)가 보의 응답(應答)에 미치는 영향(影響)을 연구(硏究)하였다. 비감표(非減表)와 임계감표(臨界減表)의 경우에 대하여도 연구(硏究)하였다. 몇몇의 이동하중속도변수(移動荷重速度變數), 축하중변수(軸荷重變數), 감표변수(減表變數)에 따른 보의 휨모멘트 윤곽(輪廓)이 도표(圖表)로 나타내졌다.

  • PDF

Experimental Method for Durability Evaluation of a Chisel Mounted on a Composite Working Implement

  • Han, Jeongwoo;Moon, Sanggon;Lee, Geunho;Kang, Daesik
    • Journal of Biosystems Engineering
    • /
    • 제42권4호
    • /
    • pp.251-257
    • /
    • 2017
  • Purpose: A chisel mounted on working implement, such as agricultural machinery used in irregular farming conditions, is subjected to highly variable fatigue loading during work. To ensure the safety of the chisel on a working implement for the duration of its service life, fatigue testing must be performed with the proper fatigue test load conditions. In this study, working loads for a chisel were developed by reconstructing loads from strain gage data collected during field tests and used to conduct fatigue tests on the chisel component. Methods: FE analysis with nCode software was utilized to select the proper quantity and locations of strain gages for load measurements. A fatigue test was performed to experimentally verify the fatigue strength of the chisel and to evaluate the validity of the load history developed with the load reconstruction technique. Results: A strain history for the chisel was obtained from data collected during field tests. The data was filtered for the 14-16 km/h speed range, connected, and merged. The chisel load history was developed using the load reconstruction technique. The resulting load history was expressed as a load spectrum using the rain-flow counting method. Conclusions: A fatigue test was conducted on a chisel under a constant load condition with an equivalent load amplitude and number of cycles, as calculated by Miner's Rule for linear damage accumulation. During the fatigue test, there were no cracks at any position. It is concluded that the fatigue test method proposed in this study can be utilized successfully as a durability evaluation method for the chisel.

Induction Generator Using PWM Converter and Its Small-Scale Power Applications to Variable-Speed Renewable-Energy Generation

  • Ahmed Tarek;Nishida Katsumi;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2005
  • This paper describes a simple control structure and power conditioning system for an indirect vector controlled stand-alone induction generator (IG) used to operate under variable speed. The required reactive power for the IG system is supplied by means of a capacitor bank and a voltage-source PWM converter. Using a capacitor bank to transfer the reactive power to the IG under the rated speed and no-load conditions starts the IG operation and reduces the PWM converter size. The vector control structure for the variable speed IG power conditioning system compensates for changes in the electrical three-phase and DC loads while considering the magnetizing curve of the IG. The vector control structure is developed to regulate the DC link voltage of the PWM converter and the IG output voltage. The experimental and simulated performance results of the IG power conditioning system at various speeds and loads are given and show that this proposed scheme can be used efficiently for a variable speed, wind energy conversion system.

대형 2행정 디젤기관용 모터구동 실린더 주유기의 성능에 미치는 퀼 어큐뮬레이터의 영향에 관한 연구 (A Study on Effect of Quill Accumulator upon Performance of Motor-driven Cylinder Lubricator in a Large Two-stroke Diesel Engine)

  • 배명환;옥현진;정화
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.115-125
    • /
    • 2007
  • Minimizing the cylinder wear and the consumption rate of cylinder oil in a large two-stroke marine diesel engine is of great economic importance. In Korea, a motor-driven cylinder lubricator for a large two-stroke marine diesel engine manufactured by $W{\ddot{a}}rtsil{\ddot{a}}$ Switzerland Co., Ltd. was first developed by authors through the joint research of industry-university in 2002. The characteristic of the developed product is that can control automatically the oil feed rate to a load fluctuation by the motor drive and the offset cam. The performance of the product is not also inferior to the conventional one. For manufacturing the reliable and useful products, however, it is necessary to investigate further characteristics and improve the performance of a cylinder lubricator. In this study, the effect of quill with and without accumulator on maximum discharge pressure, delivery delay duration and oil feed rate relative to motor revolution speed using plunger stroke as a parameter is experimentally investigated by using the developed cylinder lubricator. It is found that the maximum discharge pressure with accumulator is higher than that of no accumulator as plunger stroke and motor revolution speed are elevated, and the delivery delay duration with accumulator is shorter than that of no accumulator as plunger stroke and motor revolution speed are increased. Also, oil feed rate with accumulator is less than that of no accumulator except for a plunger stroke of 2 mm as plunger stroke and motor revolution speed are raised.

탄성기반에서 과도 열탄성 접촉에 대한 열 접촉 저항의 영향 (Effect of Thermal Contact Resistance on Transient Thermoelastic Contact for an Elastic Foundation)

  • 장용훈;이승욱
    • 대한기계학회논문집A
    • /
    • 제30권7호
    • /
    • pp.833-840
    • /
    • 2006
  • The paper presents a numerical solution to the problem of a hot rigid indenter sliding over a thermoelastic Winkler foundation with a thermal contact resistance at constant speed. It is shown analytically that no steady-state solution can exist for sufficiently high temperature or sufficiently small normal load or speed, regardless of the thermal contact resistance. However the steady state solution may exist in the same situation if the thermal contact resistance is considered. This means that the effect of the large values of temperature difference and small value of force or velocity which occur at no steady state can be lessened due to the thermal contact resistance. When there is no steady state, the predicted transient behavior involves regions of transient stationary contact interspersed with regions of separation regardless of the thermal contact resistance. Initially, the system typically exhibits a small number of relatively large contact and separation regions, but after the initial transient, the trailing edge of the contact area is only established and the leading edge loses contact, reducing the total extent of contact considerably. As time progresses, larger and larger numbers of small contact areas are established, unlit eventually the accuracy of the algorithm is limited by the discretization used.

시간에 따른 탄성지지 열탄성 접촉에 대한 열접촉저항의 영향 (Effects of Thermal Contact Resistance on Transient Thermoelastic Contacts for an Elastic Foundation)

  • 장용훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.330-333
    • /
    • 2005
  • The paper presents a numerical solution to the problem of a hot rigid indenter siding over a thermoelastic Winkler foundation with a thermal contact resistance at constant speed. It is shown analytically that no steady-state solution can exist for sufficiently high temperature or sufficiently small normal load or speed regardless of the thermal contact resistance. However, the steady state solution may exist in the same situation if the thermal contact resistance is considered. This means that the effect of the large values of temperature difference and small value of force or velocity which occur at no steady state can be lessened due to the thermal contact resistance. When there is no steady-state the predicted transient behavior involves regions of transient stationary contact interspersed with regions of separation regardless of the thermal contact resistance. Initially, the system typically exhibits a small number of relatively large contact and separation regions, but after the initial transient the trailing edge of the contact area is only established and the leading edge loses contact, reducing the total extent of contact considerably. As time progresses, larger and larger number of small contact areas are established, until eventually the accuracy of the algorithm is limited by the discretization used.

  • PDF