• 제목/요약/키워드: No-Load Test

검색결과 689건 처리시간 0.028초

Characteristic of Fatigue Crack Behavior on the Mixed-Mode in Aluminum Alloy 5083-O

  • Kim, Gun-Ho;Cho, Kyu-Chun;Lee, Ho-Yeon;Won, Young-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.899-906
    • /
    • 2011
  • Generally, load conditions of machine or structure in fatigue destruction is occurred not under single load conditions but under mixed load conditions. However, the experiment under mixing mode is insufficient because of no having test standard to the behavior of crack under mixing mode and variety of test methods, and many tests are required. In this paper measured crack direction path by created figure capture system when a experiment. Also, we studied by comparison the behavior of crack giving the change of stress ratio and inserting beach mark. Through the test under mixing mode, advancing path of crack is indicated that advancing inclined angle ${\Theta}$ (direction of specimen length) has increased depending on the increase of mixed mode impaction. It is indicated that according to the increase of mixed mode loading condition impaction under mixing mode, advancing speed of crack gets slow. Also, we found that inner crack(cross section of specimen) is progressed more rapidly than outer crack based on data through beach mark.

비탈형 영구거푸집의 현장 적용을 위한 실험적 연구 (An Experimental study on field application of Permanent form)

  • 정근호;김우재;이영도;정재영;정상진
    • 한국건축시공학회지
    • /
    • 제1권1호
    • /
    • pp.143-150
    • /
    • 2001
  • Permanent-Form is one of system forms for reducing human labor, work costs, oscillation, noise, construction wastes and so on. Permanent-Form is made from precast method in facilities, and carried in construction site to assemble with no demolding. The biggest expense to produce permanent-Form is about manufacturing mold. This papers about structural efficiency evaluation, construction efficiency test. The result of this study is below. (1) In the compressive strength test of column. Fly ash specimen and polymer specimen's strength developed as each 8%, 14% to comparison with standard specimen. The reason of this result from form section area increase and form's reinforcing bar (2) The Degree of column crack in permanent form is lower than another one's The glass fiber's fiber reinforcement effect brings like this. (3) In the flexural load test of beam, the early crack load and maximum load of permanent form use specimen showed 20% higher than standard specimen's. (4) In field application experiment, an constructional error is satisfied with the allowable margin of error, $\pm$5mm (5) When the concrete is placed into the form inside, The transformation degree of permanent form is lower than plywood form's. (6) The concrete packing ability of permanent form is satisfactory. (7) The bonding strength of permanent form shows enough strength - 6kgf/$\textrm{cm}^2$.

  • PDF

급속시공용 복합신소재 교량상부구조의 구조 성능 (Structural Performance of an Advanced Compsites Bridge Superstructure for Rapid Installation)

  • 지효선
    • 복합신소재구조학회 논문집
    • /
    • 제1권1호
    • /
    • pp.34-45
    • /
    • 2010
  • This paper describes the design, manufacturing process, testing, application, and assessment of capacity-ratings of the first all advanced composites bridge on a public highway system. In order to verify the bridge design prior to the field application, a sub-scale bridge superstructure was built and tested in the laboratory. The field load test results were compared with those of the finite element analysis for the verification of validity. To investigate its in-service performance, field load testing and visual inspections were conducted under an actual service environment. The paper includes the presentation and discussion for advanced composites bridge capacity rating based on the stress modification coefficients obtained from the test results. The test result indicates that the advanced composites bridge has no structural problems and is structurally performing well in-service as expected. Since these composite materials are new to bridge applications, reliable data is not available for their in-service performance. The results may provide a baseline data for future field advanced composites bridge capacity rating assessments and also serve as part of a long-term performance of advanced composites bridge.

  • PDF

선박용 대형 계류장비의 개발과 강도 평가 (A Study on the Development and Strength Evaluation of the Mooring Fittings with Big Capacity)

  • 김영식;김을년;김미희;김경연
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.1-7
    • /
    • 2017
  • It has been developed large mooring fittings having the capacity of 160 tons and 180 tons installed on 170K LNG FSRU. The finite element analysis for the mooring fittings was carried out in order to check the structural integrity and to confirm satisfaction of the rule requirements. The 3 kinds of mooring fittings such as chock, bollard and universal fairlead are selected for FE analysis and load test. According to the FE analysis results, all the stress levels satisfied the acceptance criteria guided by the IACS UR A2, ISO standard, ship rules and OCIMF. As test results under design load, no structural defects were found.

  • PDF

복합말뚝의 수평 거동 분석 (Analysis of lateral behavior of composite pile)

  • 선석윤;곽노경;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1195-1205
    • /
    • 2008
  • Composite piles have been used in ground conditions where conventional piles are unsuitable or uneconomical. They may consist of a combination of timber and concrete pile in Europe. One method of doing this was to drive a steel tube to just below water level, and a concrete pile was lowered down it and driven to the required level where corrosion was susceptible in U.K. Recently, a fiber reinforced polymer (FRP) composite pile was developed to use in many marine locations for piers and waterfront buildings in the USA(Hoy, 1995; Phair, 1997). A steel composite (SC) pile reinforced concrete spun pile with steel tube was also proposed and used for the foundation acting a high lateral earthquake load. Composite piles have been developed and researched to increase lateral resistance or to prevent corrosion in marine structures. In paper, the composite pile consisting of the steel upper portion and the concrete lower portion is proposed and are carried out several tests to confirm the capacity of the pile such as lateral load test, dynamic load tests and bending test. It is noted that the composite pile would be a economical pile being capable of increasing lateral resistance.

  • PDF

Monotonic Loading Tests of RC Beam-Column Subassemblage Strengthened to Prevent Progressive Collapse

  • Kim, Jinkoo;Choi, Hyunhoon
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.401-413
    • /
    • 2015
  • In this study the progressive collapse resisting capacity of a RC beam-column subassemblage with and without strengthening was investigated. Total of five specimens were tested; two unreinforced specimens, the one designed as gravity load-resisting system and the other as seismic load-resisting system, and three specimens reinforced with: (i) bonded strand, (ii) unbonded strand, and (iii) side steel plates with stud bolts. The two-span subassemblages were designed as part of an eight-story RC building. Monotonically increasing load was applied at the middle column of the specimens and the force-displacement relationships were plotted. It was observed that the gravity load-resisting specimen failed by fractures of re-bars in the beams. In the other specimens no failure was observed until the maximum displacement capacity of the actuator was reached. Highest strength was observed in the structure with unbonded strand. The test result of the specimen with side steel plates in beam-column joints showed that the force-displacement curve increased without fracture of re-bars. Based on the test results it was concluded that the progressive collapse resisting capacity of a RC frame could be significantly enhanced using unbonded strands or side plates with stud bolts.

장수명주택 벽배관 시스템의 양변기 하중저항성에 대한 실험적 연구 (An Experimental Study on the Load Resistance of Toilet Bowl in Long-Life Housing Infill System)

  • 이종호;서동구;김은영;황은경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.211-212
    • /
    • 2019
  • It is possible to realize the concept of long-life housing by utilizing the wall piping infill system. However, when using the wall piping infill system, there is no detailed standard in Korea. Problems may occur in actual use. In this study, we use the results obtained from the performance test method as a basic data. Since the load resistance test of the toilet is not available in Korea, GB 6952 (Sanitary wares) of China is applied. According to the experiment of load resistance of the toilet in this study, the strain recovery ability was good. However, it is not possible to exclude the possibility of permanent deformation of the toilet seat due to long - term repeated loading. Therefore, it is necessary to consider the stiffness enhancement of the wall (steel frame) to the fixing part when installing the toilet in the wall pipe infill system.

  • PDF

높이조절이 가능한 강재 맨홀뚜껑의 개발 (The Development of Height Adjustable Steel Manhole cover)

  • 박우철
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.581-586
    • /
    • 2018
  • 주철 맨홀뚜껑은 제조과정에서 환경오염을 유발하며, 작업환경은 매우 열악하다. 또한, 맨홀 뚜껑의 높이와 도로 표면의 높이가 일치하지 않은 경우에는 많은 불편을 초래하며 안전에도 문제를 야기한다. 본 연구에서는 주철 맨홀뚜껑을 대체할 수 있고, 도로 노면 공사 시 도로 노면 높이와 맨홀 뚜껑의 높이를 동일하게 맞추기 용이한 높이 조절이 가능한 강재 맨홀 뚜껑 구조를 제안하였다. 요구되는 품질 성능을 만족시키기 위한 맨홀 뚜껑의 구조에 대한 설계변수를 파악하기 위하여 구조 해석을 수행하였다. 요구되는 내하중 용량을 만족하는 맨홀뚜껑을 제작하기 위하여 ㄷ자 모양의 보강대에 대하여 최적 설계를 수행하였다. 높이조절부의 원통과 하부 프레임 원통은 강판을 굽힘 가공하여 원형의 형상으로 만든 후 용접에 의하여 제작하였다. 또한, 보강대도 강판을 굽힘 가공하여 제작하였다. 높이 조절용 홈은 CNC 밀링머신에 의하여 가공하였다. 4차례의 시제품을 제작하여 내하중 실험을 수행하였으며, 시험의 결과를 반영하여 새로이 제작하였다. 내하중 시험에서 용접부의 파손은 발생하지 않았으며, 주로 변형은 높이조절 홈과 가셋트 판이 접촉하는 부위에서 발생하였다. 450kN의 부하 하중에 의해 1~2.7mm의 변형이 발생하지만, 하중을 제거한 후에 거의 잔류변형이 없으며, 맨홀뚜껑의 분해 및 재조립이 가능하기 때문에 내하중 평가도 만족하는 것으로 판정받았다.

Evaluation of long-term water quality management policy effect using nonparametric statistical methods

  • Jung, Kang Young;Ahn, Jung Min;Cho, Sohyun;Lee, Yeong Jae;Han, Kun Yeun;Shin, Dongseok;Kim, Kyunghyun
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.339-352
    • /
    • 2019
  • Long term water quality change was analyzed to evaluate the effect of the Total Maximum Daily Load (TMDL) policy. A trend analysis was performed for biochemical oxygen demand (BOD) and total phosphorus (TP) concentrations data monitored at the outlets of the total 41 TMDL unit watersheds of the Nakdong River in the Republic of Korea. Because water quality data do not usually follow a normal distribution, a nonparametric statistical trend analysis method was used. The monthly mean values of BOD and TP for the period between 2004 and 2015 were analyzed by the seasonal Mann-Kendall test and the locally weighted scatterplot smoother (LOWESS). The TMDL policy effect on the water quality change of each unit watershed was analyzed together with the results of the trend analysis. From the seasonal Mann-Kendall test results, it was found that for BOD, 7.8 % of the 41 points showed downward trends, 26.8 % and the rest 65.9% showed upward and no trends. For TP, 51.2% showed no trends and the rest 48.8% showed downward trends. From the LOWESS analysis results, TP began to decrease in most of the unit watersheds from mid-2010s when intensive chemical treatment processes were introduced to existing wastewater treatment plants. Overall, for BOD, relatively more points were improved in the main stream compared to the points of the tributaries although overall trends were mostly no trend or upward. For TP, about half of the points were improved and the rest showed no trends.

긴장력이 도입된 콘크리트 충전 강관말뚝을 사용한 복합말뚝의 수평거동 특성 (Lateral Behavior of Hybrid Composite Piles Using Prestressed Concrete Filled Steel Tube Piles)

  • 박노원;백규호
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.133-143
    • /
    • 2018
  • 수평하중에 대한 말뚝의 휨강도를 증대시키기 위해 얇은 두께의 강관 내부에 PHC말뚝을 합성한 콘크리트 충전 강관(PCFT)말뚝이 개발되었다. PCFT말뚝의 휨강도를 강관말뚝과 비교하기 위하여 직경이 동일한 PCFT말뚝과 강관 말뚝에 대해 휨강도시험을 수행함과 동시에 한계상태설계법으로 P-M 상관도를 작도하였다. 그리고 PCFT말뚝의 하단에 PHC말뚝을 연결한 PCFT 복합말뚝의 수평지지력과 수평거동을 기존의 강관 복합말뚝(HCP) 및 강관말뚝과 비교하기 위하여 총 4본의 시험말뚝을 시공하고 수평재하시험을 수행하였다. 휨강도시험 결과 PCFT말뚝의 휨강도는 두께 12mm의 강관말뚝보다 18.7% 향상되었고, 동일한 휨하중에서 말뚝의 변위량은 강관말뚝보다 50% 감소하였다. 그리고 P-M 상관도로부터 연직하중을 받는 PCFT말뚝은 강관말뚝보다 휨내력이 크게 증가한 반면, 인발하중을 받는 PCFT 말뚝은 강관말뚝보다 휨내력이 감소함을 알 수 있었다. 또한 시험말뚝에 대한 수평재하시험의 결과에 따르면 상부말뚝의 길이가 동일한 경우 PCFT 복합말뚝은 HCP보다 수평지지력이 60.5% 컸고, 두께가 12mm인 강관말뚝보다 35.8% 큰 것으로 나타났다.