Effects of Insulation Layer upon the Thermal Behavior of Linear Motors

  • Eun, In-Ung
    • Journal of Mechanical Science and Technology
    • /
    • 제17권6호
    • /
    • pp.896-905
    • /
    • 2003
  • A linear motor has many advantages next to conventional feed mechanisms: high transitional speed and acceleration, high control performance, and good positioning accuracy at high speed. Through the omission of a power transfer element, the linear motor shows no wear and no backlash, has a long lifetime, and is easy to assemble. A disadvantage of the linear motor is low efficiency and resultant high-temperature rise in itself and neighboring structures during operation. This paper presents the thermal behavior of the linear motor as a feed mechanism in machine tools. To improve the thermal behavior, an insulation layer is used. By placing the insulation layer between the primary part and the machine table, both the temperature difference and the temperature fluctuation in the machine table due to a varying motor load are reduced.

현장측정을 통한 발코니 창호의 차음성능에 관한 연구 (Investigation of the sound insulation performance of balcony window through field measurement)

  • 주문기
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.63-68
    • /
    • 2009
  • As with the disappearance of a living room window due to the trend in apartment housing construction that prefers a larger, expanded living room, the sound insulation performance of the balcony window is becoming an important factor to determine the level of indoor noise at an apartment unit. Considering that the indoor noise inside an apartment unit is mandated by law at or below 45dB(A), the balcony window is increasingly assuming an even more important role. Sound insulation performance of the window was measured by examining differences in data involving varying angles of incidence of the sound source as obtained from the same balcony window. Also, acoustic intensity measuring was performed at and around the window to determine its sound insulation quality. Results of measuring on the sound source's angles of incidence indicated that the performance showed some differences in lower frequency ranges, though with no significance. Intensity measuring results showed that the sound insulation performance was reduced near the connection part of the window and the window frame.

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.

고압전동기 고정자 권선의 유전정접 특성 (Characteristics of Dissipation Factor in High Voltage Motor Stator Windings)

  • 김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.93-94
    • /
    • 2008
  • Diagnostic tests were performed in three high voltage motors. These tests included insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. NO.1 and No.2 motors failed near rated voltage of 14.0 kV, respectively. These motors are lower that expected for good quality coils in 6.6 kV class motors. The breakdown voltage of No.3 motor was 15.0 kV.

  • PDF

국내 섬유질 단열재의 내화성능에 관한 연구 (A Study on the Fire Resistance of Korean Cellulose Insulation)

  • 권영철;황정하;유형규
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.10-16
    • /
    • 2008
  • The fire resistance of thermal insulation and interior finishing materials is recently much emphasized after the fire accident at the Icheon Cold Store in January 2008. Three kinds of thermal insulation are used in buildings. They are Organic, Non-organic and cellulosic insulation. Organic insulation such as polystyrene foam board and urethane foam has high thermal resistance but it has no fire resistance. While non-organic insulation such as rockwool and glassfiber has high fire resistance, it has lower thermal resistance than organic insulation. Cellulose insulation is primarily manufactured from recycled newsprint or cardboard using shredders and fiberizers. Despite of its environmental friendliness and high thermal resistivity, its domestic use has not much increased because of the prejudice that paper can easily burn. However, the cellulose insulation as a product is about 80 wt.% cellulosic fiber and 20 wt.% chemicals, most of which are fire retardants such as boric acid and ammonium sulfate. It is required to secure its fire safety for more consumption as a building insulation in Korea. Therefore, this study investigates the fire resistance of Korean cellulose insulation according to the rate of fire retardant and finally presents the optimum rate of fire retardant in cellulose as building insulation. The fire safety test was conducted according to the ASTM C 1485-00. The test results indicate that above 18 wt% of fire retardant is necessary to secure the fire safety of cellulose insulation.

고압전동기 절연진단 결과 추이관리의 문제점 분석 (Analytic Issues for Trend Management on Insulation Diagnositic for High Voltage Motors)

  • 이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2052-2053
    • /
    • 2008
  • High voltage motors are the core equipment of electric generation facilities and need to guarantee stable operation. Therefore, keeping healthy state is of importance by means of insulation diagnosis periodically. However, if the diagnosis went through in the different circumstances such as temperature, humidity, and impedance applied to the test equipment, the trend analysis have no significance. This paper presents the experimental results supporting the importance of keeping the same conditions under insulation diagnosis.

  • PDF

외국 지중배전케이블의 특성분석 (Characterization of Foreign Undergrounded Distribution Cables)

  • 고정우;오우정;김종은;서광석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.428-431
    • /
    • 1997
  • In order to compare with domestic underground distribution cables, the foreign cable which was manufactured in USA, 1982 and has been serviced in field for 13 years was characterized with several tests. Water trees, voids, and convolutions are not found in insulation. In hot oil test, insulation is very clean and there was no separation of insulation and conductor shield. The results of degree of crosslinking, FTIR, and DSC are also usual. Specially, the distribution of OIT is very good, which is different from that of domestic cables. The content of impurities is relatively small. This cables was manufactured with good state and no extraordinary degradation is found.

  • PDF

단열 파우더를 채용한 LNGCC의 BOR예측에 관한 연구 (A Study on the Boil-Off Rate Prediction of LNG Cargo Containment Filled with Insulation Powders)

  • 한기철;황순욱;조진래;김준수;윤종원;임오강;이시복
    • 한국전산구조공학회논문집
    • /
    • 제24권2호
    • /
    • pp.193-200
    • /
    • 2011
  • 본 연구를 통해 superlite라 불리는 단열 파우더를 채용한 NO96 멤브레인 타입 LNG선 단열 화물창의 만선항해 시 LNG의 BOR(Boil-Off Rate) 예측모델을 제시하였다. LNGCC(LNG Cargo Containment)의 비정상상태 열전달 FEM모델은 만선항해 시 대기 및 해수 조건을 반영하고 복잡한 화물창 단열구조에 균질화 기법을 적용하여 구축하였다. BOR은 만선항해중 LNGCC 내부로 침입하는 총 열량을 이용하여 평가되었으며, 주요 변수에 따른 BOR의 변화는 파라메트릭 열전달해석을 통하여 분석하였다. 그리고 파라메트릭 BOR 특성해석 결과를 토대로 LNG선의 탱크 크기, 단열층의 두께 그리고 superlite의 열전도율을 함수로 하는 BOR 예측모델을 유도하였다. 비선형 과도 열전달해석을 통해 직접 구한 BOR과의 비교를 통해 유도한 예측모델은 최대 1% 이내의 상대오차를 나타내었다.

-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향 (Influence on Meridians Electric Potential for Electrical Ground and Insulation)

  • 이용흠;이균정;김은근;김한성;신태민
    • 한국정보통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

Contact resistance increment of no-insulation REBCO magnet during a quench

  • Im, Chaemin;Cho, Mincheol;Bang, Jeseok;Kim, Jaemin;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권1호
    • /
    • pp.31-35
    • /
    • 2019
  • The lumped-parameter circuit model for a no- insulation (NI) high temperature superconductor (HTS) magnet has been well understood after many experimental and analytic studies over a decade. It successfully explains the non-linear charging behaviors of NI magnets. Yet, recently, multiple groups reported that the post-quench electromechanical behaviors of an NI HTS magnet may not be well explained by the lumped circuit model. The characteristic resistance of an NI magnet is one of the key parameters to characterize the so-called "NI behaviors" of an NI magnet and recently a few groups reported a potential that the characteristic resistance of an NI magnet may substantially vary during a quench. This paper deals with this issue, the increment of contact resistance of the no-insulation (NI) REBCO magnet during a quench and its impact on the post-quench behaviors. A 7 T 78 mm NI REBCO magnet that was previously built by the MIT Francis Bitter Magnet Laboratory was chosen for our simulation to investigate the increment of contact resistance to better duplicate the post-quench coil voltages in the simulation. The simulation results showed that using the contact resistance value measured in the liquid nitrogen test, the magnitude of the current through the coil must be much greater than the critical current. This indicates that the value of the contact resistance should increase sharply after the quench occurs, depending on the lumped circuit model.