• Title/Summary/Keyword: Ni-S

Search Result 2,429, Processing Time 0.033 seconds

Effect of Ni/Fe Ion Concentration Ratio on Fuel Cladding Crud Deposition (핵연료 피복관 부식생성물 부착에 관한 Ni/Fe 이온 농도비의 영향)

  • Baek, S.H.;Kim, U.C.;Shim, H.S.;Lim, K.S.;Hur, D.H.
    • Corrosion Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2014
  • The objectives of this study are to investigate the effect of the concentration ratios of Ni and Fe ions on crud deposition onto the fuel cladding surface in the simulated primary environments of a pressurized water reactor. Crud deposition tests were conducted in the Ni and Fe concentration ratios of 20:20 ppm, 39:1 ppm and 1:39 ppm at $325^{\circ}C$ for 14 days. In the case of the same Ni and Fe ion ratio (20:20), nickel ferrite with a polyhedral shape was formed. Nickel oxide deposits with a needle shape were formed in the condition of high Ni to Fe ion ratio (39:1), While polyhedral iron oxide and needle-like nickel oxide formed in the condition of low Ni to Fe ion ratio (1:39). The amount of deposits increased, when Fe oxides were formed. This indicates that Fe rich oxides stimulated Ni oxide deposition.

Effects of Heat Treatment Temperature on Oxidation Behavior in Ni-Ti Alloy (Ni-Ti 합금의 산화거동에 영향을 미치는 열처리 온도의 영향)

  • Kim, K.S.;Kim, W.C.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.1
    • /
    • pp.3-7
    • /
    • 2009
  • Variation in oxidation behavior with heat treatment temperature is investigated for a Ni-Ti alloy using X-ray diffraction, DSC (differential scanning calorimetry) and Auger electron spectroscopy. And the effect of oxidation on transformation behavior and superelasticity is characterized. A cold-worked 50.6Ni-Ti alloy is oxidized at 300-$700^{\circ}C$ for 1 hr in the air atmosphere. With an increase in heating temperature, the structure of $TiO_2$ changes from amorphous (300 and $400^{\circ}C$) to anatase ($500^{\circ}C$), and to rutile ($700^{\circ}C$). Activation energy of oxidation for NiTi is measured to be 51 Kcal/mol when heating temperature is $500^{\circ}C$ or above. Since Ti reacts preferably with oxygen, Ni content increases between matrix and oxide, forming $Ni_{3}Ti$ compounds. The resultant of oxidation decreases significantly $M_s$ and $A_s$ temperature in the specimen oxidized at $900^{\circ}C$ with $B_2{\rightarrow}M$ transformation path. An extra is found on cooling between two peaks in the specimen with $B_2{\rightarrow}R{\rightarrow}M$ one which is oxidized at $900^{\circ}C$ and aged at $500^{\circ}C$. Oxidation deteriorates superelasticity due to formation of Ni-rich compound.

A nuclear battery based on silicon p-i-n structures with electroplating 63Ni layer

  • Krasnov, Andrey;Legotin, Sergey;Kuzmina, Ksenia;Ershova, Nadezhda;Rogozev, Boris
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1978-1982
    • /
    • 2019
  • The paper presents the electrical performance measurements of a prototype nuclear battery and two types of betavoltaic cells. The electrical performance was assessed by measuring current-voltage properties (I-V) and determining the short-circuit current and the open-circuit voltage. With 63Ni as an irradiation source, the open-circuit voltage and the short-circuit current were determined as 1 V and 64 nA, respectively. The prototype consisted of 10 betavoltaic cells that were prepared using radioactive 63Ni. Electroplating of the radioactive 63Ni on an ohmic contact (Ti-Ni) was carried out at a current density of 20 mA/㎠. Two types of betavoltaic cells were studied: with an external 63Ni source and a 63Ni-covered source. Under irradiation of the 63Ni source with an activity of 10 mCi, the open-circuit voltage Voc of the fabricated cells reached 151 mV and 109 mV; the short-circuit current density Jsc was measured to be 72.9 nA/cm2 and 64.6 nA/㎠, respectively. The betavoltaic cells had the fill factor of 55% and 50%, respectively.

Quantitative Surface Analysis of Co-Ni and Au-Cu alloys by XPS and SIMS (XPS와 SIMS에 의한 Co-Ni과 Au-Cu 합금표면 정량분석 연구)

  • 김경중;문대원;이광우
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.106-114
    • /
    • 1992
  • Abstract-Quantitative surface analysis of Co-Ni and Au-Cu alloys by XPS and SIMS was studied. For Co-Ni alloy, quantitative XPS analysis could be done within 1-2% relative error with pure element standards without any correction. For Au-Cu, quantitative XPS analysis was not possible without any correction. But it could be done with standard alloys of various composition within 1-2% relative error. Without standard alloys, Au-Cu alloys could be analyzed by XPS within 10% relative error with pure element standards. For SIMS analysis of Co-Ni alloys, the relative secondary ion yields of Co+/Nit has linear relation with ratio of each composition so that quantitative SIMS analysis was possible for Co-Ni alloys. Preliminary results of XPS round robin test of VAMAS-SCA Japan Project are given.

  • PDF

Highly Sensitive Trimethylamine Sensing Characteristics of V-doped NiO Porous Structures (바나듐이 도핑된 NiO 다공성 구조의 고감도 Trimethylamine 감응 특성)

  • Park, Sei Woong;Yoon, Ji-Wook;Park, Joon-Shik;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.218-222
    • /
    • 2016
  • Pure and V-doped NiO porous structures were prepared by the evaporation-induced surfactant assembly and subsequent pyrolysis of assembled structures, and their gas sensing characteristics were investigated. Pure NiO porous structures showed negligible gas responses (S=$R_g/R_a$, $R_g$: sensor resistance in analytic gas; $R_a$: sensor resistance in air) to 5 ppm trimethylamine (S=1.17) as well as other interfering gases such as ethanol, p-xylene, toluene, benzene and formaldehyde (S=1.02-1.13). In contrast, the V-doped NiO porous structures exhibited a high response and selectivity to 5 ppm trimethylamine (S=14.5) with low cross-responses to other interfering gases (S=4.0-8.7) at $350^{\circ}C$. The high gas response of V-doped NiO porous structures to trimethylamine was explained by electronic sensitization, that is, the increase in the chemoresistive variation due to the decrease in the hole concentration. The enhanced selectivity to trimethylamine was discussed in relation to the interaction between basic trimethylamine gas and acidic V catalysts.

Studies on The Elution Behavior of Ni(II)-${\alpha}$-isonitroso-${\beta}$-diketone Imine Chelates in Reversed-Phase Liquid Chromatography

  • Lee, Won;Kim, In-Whan;Kim, Mi-Kyoung;Kim, Yong-Jun;Jung, Hae-Rim;No, Kyoung-Tai;Kim, Su-Yeon
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.519-527
    • /
    • 1995
  • The retention mechanism of Ni(II)-${\alpha}$-isonitroso-${\beta}$-diketone imine chelates in reversed-phase HPLC has been studied by examining the effect of temperature, mobile phase composition in acetonitrile-water mixture, and molecular structure on retention. The empirical retention equation was investigated to evaluate the properties of S (hydrophilic index). The value of the S index of the Ni(II) chelates decrease with the increasing column temperature and a linear relationship between S and log $k{_w}^{\prime}$ has been found. The results showed that the S index is influenced by the interaction between Ni(II) chelates and mobile phase. Molecular properties, van der Waals molar volume, polarizability and dipole moment, of the Ni(II) chelates were calculated by Cerius 2 program and the calculations were performed at Universal Force Field (UFF) model. The S value and log $k{_w}^{\prime}$ increase with decreasing the dipole moment of Ni(II) chelates.

  • PDF

Characteristics of Magnetic Tunnel Junctions Comprising Ferromagnetic Amorphous NiFeSiB Layers (강자성 비정질 NiFeSiB 자유층을 갖는 자기터널접합의 스위칭 특성)

  • Hwang, J.Y.;Rhee, S.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.6
    • /
    • pp.279-282
    • /
    • 2006
  • Magnetic tunnel junctions (MTJs), which consisted of amorphous ferromagnetic NiFeSiB free layers, were investigated. The NiFeSiB layers were used to substitute for the traditionally used CoFe and/or NiFe layers with the emphasis being given to obtaining an understanding of the effect of the amorphous free layer on the switching characteristics of the MTJs. $Ni_{16}Fe_{62}Si_{8}B_{14}$ has a lower saturation magnetization ($M_{s}:\;800\;emu/cm^{3}$) than $Co_{90}Fe_{10}$ and a higher anisotropy constant ($K_{u}:\;2700\;erg/cm^{3}$) than $Ni_{80}Fe_{20}$. The $Si/SiO_{2}/Ta$ 45/Ru 9.5/IrMn 10/CoFe $7/AlO_{x}/CoFeSiB\;(t)/Ru\;60\;(in\;nanometers)$structure was found to be beneficial for the switching characteristics of the MTJ, leading to a reduction in the coercivity ($H_{c}$) and an increase in the sensitivity resulted from its lower saturation magnetization and higher uniaxial anisotropy. Furthermore, by inserting a very thin CoFe layer at the tunnel barrier/NiFeSiB interface, the TMR ratio and switching squareness were improved more with the increase of NiFeSiB layer thickness up to 11 nm.

The Study of Ni-Pd Alloy Characteristics to Form a NiSi for Shallow S/D Junction (Shallow S/D Junction에 적용 가능한 NiSi를 형성하기 위한 Ni-Pd 합금의 특성 연구)

  • Lee, Won-Jae;Oh, Soon-Young;Agchbayar, Tuya;Yun, Jang-Gn;Kim, Yong-Jin;Zhang, Ying-Ying;Zhong, Zhun;Kim, Do-Woo;Cha, Han-Seob;Heo, Sang-Bum;Wang, Jin-Suk;Lee, Hi-Deok
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.603-606
    • /
    • 2005
  • In this paper, the formation and thermal stability of Ni-silicide using Ni-Pd alloys is studied for ultra shallow S/D junction of nano-scale CMOSFETs. There are no different effects when Ni-Pd is used in single structure and TiN capping structure. But, in case of Cobalt interlayer structure, it was found that Pure Ni had lower sheet resistance than Ni-Pd, because of a thick silicide. Also, Ni-Pd has merits that surface of silicide and interface between silicide and silicon have a good morphology characteristics. As a result, Ni-Pd is an optimal candidate for shallow S/D junction when cobalt is used for thermal stability.

  • PDF

Portable Amperometric Glucose Detection based on NiS/CuS Nanorods Integrated with a Smartphone Device

  • Heyu Zhao;Kaige Qu;Haoyong Yin;Ling Wang;Yifan Zheng;Shumin Zhao;Shengji Wu
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.252-261
    • /
    • 2023
  • Glucose detection is particularly important for clinical diagnosis and personal prevention and control. Herein, the smartphone-based amperometric glucose sensors were constructed using the NiS/CuS nanorods (NRs) as sensing electrodes. The NiS/CuS NRs were prepared through a facile hydrothermal process accompanied by the subsequent vulcanization treatment. The morphological and structural properties of NiS/CuS NRs were characterized with SEM, EDS, XRD, and XPS. Electrochemical measurements including cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy display that NiS/CuS NRs can act as highly efficient electrocatalyst for glucose detection. The NiS/CuS NRs electrodes present a wide detection range of 1-8000 µM for glucose sensing with the sensitivity of 956.38 µA·mM-1·cm-2. The detection limit was 0.35 µM (S/N=3). When employed in smartphone-based glucose sensing device, they also display a high sensitivity of 738.09 µA·mM-1·cm-2 and low detection limit of 1.67 µM. Moreover, the smartphone-based glucose sensing device also presents favorable feasibility in determination of glucose in serum samples with the recoveries ranging between 99.5 and 105.8%. The results may provide a promising viewpoint to design other new portable glucose sensors.

Biocompatibility and Mechanical Performance of Ni-Ti

  • Kim, J.H.;Choi, Y.C.;Kim, H.S.;Hong, S.I.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1257-1258
    • /
    • 2006
  • Biomimetic apatite deposition behaviors and mechanical performance for as-rolled and annealed Ni-Ti plates were investigated . A good biomimetic apatite formation and excellent mechanical performance of Ni-Ti suggests that Ni-Ti can be an excellent candidate material as orthopedic implants.

  • PDF