• 제목/요약/키워드: Ni coated steel

검색결과 58건 처리시간 0.023초

Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets

  • Kim, Yunmi;Cha, Jung-Yul;Hwang, Chung-Ju;Yu, Hyung Seog;Tahk, Seon Gun
    • 대한치과교정학회지
    • /
    • 제44권4호
    • /
    • pp.157-167
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the clinical efficacy of polymer- and rhodium-coated wires compared to uncoated wires by measuring the frictional forces using self-ligation brackets. Methods: 0.016-inch nickel titanium (NiTi) wires and $0.017{\times}0.025$-inch stainless steel (SS) wires were used, and the angulations between the brackets and wires were set to $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$. Upper maxillary premolar brackets (Clippy-C$^{(R)}$) with a 0.022-inch slot were selected for the study and a tensile test was performed with a crosshead speed of 5 mm/min. The maximum static frictional forces and kinetic frictional forces were recorded and compared. Results: The maximum static frictional forces and the kinetic frictional forces of coated wires were equal to or higher than those of the uncoated wires (p < 0.05). The maximum static frictional forces of rhodium-coated wires were significantly higher than those of polymercoated wires when the angulations between the brackets and wires were set to (i) $5^{\circ}$ in the 0.016-inch NiTi wires and (ii) all angulations in the $0.017{\times}0.025$-inch SS wires (p < 0.05). The kinetic frictional forces of rhodium-coated wires were higher than those of polymer-coated wires, except when the angulations were set to $0^{\circ}$ in the 0.016-inch NiTi wires (p < 0.05). Conclusions: Although the frictional forces of the coated wires with regards to aesthetics were equal to or greater than those of the uncoated wires, a study under similar conditions regarding the oral cavity is needed in order to establish the clinical implications.

질소이온주입된 초내식성 스테인리스강의 마모부식 특성 (Wear Corrosion Behaviour of Nitrogen Ion Implanted Super Stainless Steel)

  • 강선화;김철생
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.175-177
    • /
    • 1994
  • The wear corrosion behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr - 20Ni - 6Mo - 0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The Cr and Ni amounts won out from the materials were investigated using an electrothermal atomic absorption spectrometry. We observed that the Cr dissolution rate of the S.S.S was similar to that of 316L SS, however, the Ni release of the S.S.S was feater than 316L SS. The metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. The wear corrosion behaviour of the stainless steels was not correlated with the results shown by a static metal ion release test.

  • PDF

Fe-3.0Ni-0.7Cr-1.4Mn-X강의 고주기피로특성에 미치는 질화/DLC코팅의 영향 (The Effect of Nitriding/DLC Coating on the High Cycle Fatigue Properties of Fe-3.0Ni-0.7Cr-1.4Mn-X Steel)

  • 장재철;김송희
    • 한국표면공학회지
    • /
    • 제49권6호
    • /
    • pp.587-594
    • /
    • 2016
  • Various surface treatments and thin film coating processes on the surface of injection die steel have been developed to extend the life. Most of previous studies were mainly focused on investigating the wear and static bonding behavior of thin films. In this study complex surface treatments of DLC coating combined with ion nitriding were applied to increase fatigue life and wear resistance. Ion nitriding, DLC coating, and DLC coating following nitriding on the surface of Fe-3.0Ni-0.7Cr-1.4Mn-X steel were investigated to uncover the beneficial effect which is applicable to injection die. The effect of various surface treatments and coating conditions on high cycle fatigue resistance was studied. Surface morphology change during fatigue tests were observed with AFM. Fatigue life of the die steel increased by 10 to 1,000 times at the various level of stress amplitudes in the condition of DLC coating following the ion nitriding for 3 hrs comparing with the only DLC coated condition.

고주파 연소합성 코팅된 Ni-Al계 금속간화합물의 미끄럼 마모 특성에 미치는 볼 밀링의 영향 (Effects of Ball Milling on Sliding Wear Behavior of Ni-Al Intermetallics Coated on Mild Steel through Induction Heating Process)

  • 이한영
    • Tribology and Lubricants
    • /
    • 제34권6호
    • /
    • pp.284-291
    • /
    • 2018
  • Ball-milling for reactant powders in advance and using an induction heating system for Ni-Al intermetallic coating process are known to enhance the reactivity of combustion synthesis. In this work, the effects of the charging weight ratio of ball to powder in ball-milling for reactant Ni-Al powders and the synthesizing temperature in induction heating on sliding wear behavior of the coating layers are investigated. Sliding wear behavior of the coating layers is examined against a tool steel using a pin-on-disc type sliding wear machine. As results, wear of the coating layer ball-milled without ball was severely worn out at the sliding speed of 2m/s, regardless of the synthesizing temperature in induction heating. However, the wear rate of the coating layers at the sliding speed was remarkably decreased with increasing the charging weight ratio of ball in ball-milling for reactant powders. This can be explained by the fact that the void in the coating layer is disappeared and the coating layer is densified by the ball-milling. The evidence showed that pitting damages were disappeared on the worn surface of ball-milled coating layer. Consequentially, the Ni-Al intermetallic coating layer could have better wear resistance at all sliding speed ranges with the ball-milling for reactant powders in advance.

펄스 도금법을 이용한 STS 316L 스테인리스강 상의 저온 염욕 알루미늄 코팅에 관한 연구 (Study of the Al-coating on the STS 316L Stainless Steel by Pulse Plating in the Molten Salts at Room Temperature)

  • 정세진;조계현
    • 한국표면공학회지
    • /
    • 제35권1호
    • /
    • pp.17-32
    • /
    • 2002
  • Electroplating methods by molten salts and non-aqueous melts were employed for aluminium coating on STS 316L stainless steel. After coated with Ni or non-coated surface on stainless steel, Al pulse plating was carried out in two different types of electrolytes at room temperature. The Al layer from $AlCl_3$-TMPAC melts could not obtain appreciable thickness for engineering application due to chemical reactions between deposits and moisture of air. However, The Al coating by pulse plating in the Ethylbenzene-Toluene-$AlBr_3$ systems was found to be solid coating layer with a few $\mu\textrm{m}$ scale. The conductivity of Ethylbenzene-Toluene-$AlBr_3$ electrolyte was as functions of time and agitation. By seven days exposure after mixing of the electrolyte, Al-deposited layer shows uniform and near by pore-free with high current density (higher than 30mA/$\textrm{cm}^2$). The roughness and imperfection of coating layer were decreased with a increasing agitation speed. It was found that the optimum condition for the Al pulse plating on the 316L stainless steel was a 400mA peak current, duty cycle, $t_{on}$ $t_{ off}$=3ms/1ms, and a current density of 30mA/$\textrm{cm}^2$.

MCFC용 wet-seal부의 내식성 향상을 위한 NiAl/Y 피복 공정에 관한 연구 (NiAl/Y Coating Process for Corrosion Resistance of Wet-seal area in MCFC)

  • 최재웅;강성군;송상빈;황응림
    • 한국재료학회지
    • /
    • 제11권8호
    • /
    • pp.666-670
    • /
    • 2001
  • 용융탄산염 연료전지(MCFC)의 상용화에 있어서 가장 큰 문제점으로 지적되고 있는 분리판 wet-seal부의 내식성 향상을 위해 AISI 316L 스테인레스강에 Ni은 전기도금법으로, Y과 Al은 e-beam PVD법으로 피복하여 Ni/Y/Al충을 형성시켰다.$ 800^{\circ}C$ 환원분위기에서 5시간의 열처리를 통해 NiAlY 합금층을 얻을 수 있었으며, 그 후 $650^{\circ}C$ 용융탄산염내에서 as-received AISI 316L 스테인레스강과 200시간의 침지실험을 퉁해 내식성이 비교.평가되었다. SEM/EDS를 통한 단면 관찰 결과, Y의 첨가에 의해 치밀한 산화막을 형성하여 분리판 wet-seal부의 내식성을 향상시킬 수 있었다.

  • PDF

Fabrication of Low Carbon Steel Coated with 18%Cr-2.5%Ni-Fe Powder by Laser Cladding and Its Application on Plastic Injection Mold for Aluminum Diecasting

  • Kim, Cheol-Woo;Yoo, Hyo-Sang;Cho, Kyun-Taek;Jeon, Jae-Yeol;Choi, Se-Weon;Kim, Young-Chan
    • 한국재료학회지
    • /
    • 제31권11호
    • /
    • pp.601-607
    • /
    • 2021
  • Laser cladding a surface treatment process that grants superior characteristics such as toughness, hardness, and corrosion resistance to the surface, and rebuilds cracked molds; as such, it can be a strong tool to prolong service life of mold steel. Furthermore, compared with the other similar coating processes - thermal spray, etc., laser cladding provides superior bonding strength and precision coating on a local area. In this study, surface characteristics are studied after laser cladding of low carbon steel using 18%Cr-2.5%Ni-Fe powder (Rockit404), known for its high hardness and excellent corrosion resistance. A diode laser with wavelength of 900-1070 nm is adopted as laser source under argon atmosphere; electrical power for the laser cladding process is 5, 6, and 10 kW. Fundamental surface characteristics such as crossectional microstructure and hardness profile are observed and measured, and special evaluation, such as a soldering test with molten ALDC12 alloy, is conducted to investigate the corrosion resistance characteristics. As a result of the die-soldering test by immersion of low carbon alloy steel in ALDC12 molten metal, the clad layer's soldering thickness decreases.

HA 코팅된 스테인레스강과 뼈의 계면에서의 경조직 성장 및 결합력 향상 (Bone Ingrowth and Enhancement of Bone Bonding Strength at Interface between Bone and HA Coated Stainless Steel)

  • 김철생;김상윤;김동헌;강곤
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.133-136
    • /
    • 1996
  • We investigated how hydroxyapatite (HA) coating onto a porous super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) affects bone ingrowth in a dog transcortical femoral model. Implants were histologically evaluated after 4 and 48 weeks of implantation, and the bone bonding strength at the bone/implant interface was examined by employing the pull-out test. The direct osseous tissue bonding onto the HA-coated S.S.S was observed, but the uncoated stainless steels had thin fibrous tissue layers. The mean interface strength of the HA-coated S.S.S was 1.5 and 2.5 times greater than those of the S.S.S and the 316L SS after one year of implantation, respectively. In preliminary studies, no toxic responce was observed from a cytotoxicity test of the S.S.S, having similar corrosion resistance to titanium. Our results suggest that early osteoconductive nature of HA coating may induce long term osteointegration for a bioinert substrate.

  • PDF

Ni-Al계 금속간화합물의 고주파 연소합성코팅에 미치는 볼 밀링의 영향 (Effects of Ball Milling for Elemental Powders on Ni-Al based Intermetallics Coating on Mild Steel through Induction Heating Process)

  • 이한영;박원규
    • Tribology and Lubricants
    • /
    • 제33권6호
    • /
    • pp.296-302
    • /
    • 2017
  • Ball milling of elemental powders in advance and using an induction heating system for intermetallic coatings are known to enhance the reactivity of combustion synthesis. In this work, the effects of simultaneously applying these two incentive methods on the properties of intermetallic coatings are studied. Ni-Al powder compacts ball-milled with three different ball-to-powder weight ratio mixtures are synthesized and coated on mild steel by combustion synthesis in an induction heating system. Consequently, similar to an electrical heating system, the positive effects of ball milling on the combustion synthesis are confirmed in the induction heating system. The enhancement in synthetic reactivity achieved by applying the two incentive methods at the same time is greater than that by applying each incentive method separately. In particular, the enhancement is remarkable at low reaction temperature. However, there are limitations to improving the reactivity by simultaneously applying the two incentive methods to the combustion synthesis, unlike the reaction temperature. The microstructure and hardness of the coating layer are both influenced by the ball-charging ratio employed in the ball-milling process.

저탄소강 SS41 연속파형 Nd:YAG 레이저 겹치기 용접의 기공제어 기술 (The Porosity Control Technology of Lap Joint Welding Using Continuous Wave Nd:YAG Laser of the Low Carbon Steel SS41)

  • 이가람;황찬연;양윤석;박은경;유영태
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.665-672
    • /
    • 2013
  • With the development of advanced processing technology, laser processing systems, which require high-quality precision processing, have attracted considerable attention. Although laser equipment is expensive, it enables quick processing and less deformation of materials. This technology is often applied to secondary batteries, which has thus farinvolved the use of argon tungsten inert gas (TIG) welding. However, the welding characteristics of argon TIG welding are not yet good, and a laser is used for welding to address this problem. In this study, lap-joint welding was conducted, and the desired welding characteristics were obtained when the laser power was 1800W and the laser beam travel speed was 1.8 m/min. Lap-joint welding was conducted on Ni-coated SS41. Two cases were compared. No pores were observed in the Ni-coated SS41 lap-joint welding part, and cracks appeared from the lap-joints. Moreover, the pole rod and tap were welded together in a T-joint form to improve the output of the secondary battery. T-joint laser welding showed better welding characteristics than TIG welding.