• Title/Summary/Keyword: Neutral-point clamped

Search Result 156, Processing Time 0.024 seconds

Predictive Control of 5-level NPC/H-bridge inverter (5-레벨 NPC/H-브릿지 인버터의 예측 제어)

  • Cho, Hyun-ki;Kwak, Sang-shin
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.21-22
    • /
    • 2014
  • 본 논문은 5-레벨 NPC/H-브릿지 (Neutral Point Clamped/H-bridge) 인버터의 최적 제어 세트 (finite-control-set) 모델 예측 제어 (MPC: Model Predictive Control) 방법을 제안한다. NPC/H-브릿지 인버터의 출력 전류 제어 및 DC-link 커패시터 전압 균형을 유지하기 위해 출력 전류와 DC-link 커패시터 전압을 예측하고, 하나의 비용 함수 (cost function)을 통해 최적의 스위칭 상태를 출력한다. PSIM 시뮬레이션을 통해 제안된 제어 알고리즘의 검증하였다.

  • PDF

Harmonic Elimination Technique using Digital Software controlled NPC PWM Inverter (디지틀 소프트웨어 제어 NPC PWM 인버어터를 이용한 고조파 제거 기법)

  • 윤병도;김윤호;김철우;송언빈
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.5
    • /
    • pp.43-50
    • /
    • 1993
  • 본 논문에서는 인버어터의 출력 파형에 포함되는 고조파를 제거하기 위하여, 디지틀 소프트웨어에 의한 NPC(Neutral Point Clamped) PWM 인버어터 제어기법을 제시하였다. 제안한 기법은 고조파 전류율과 파형 왜율을 낮출 수 있고, 인버어터의 성능을 크게 개선할 수 있다. 주파수 비를 36으로 하고, 변조지수를 1.2∼2.0의 범위에서 제어하였을 때, 대부분의 고조파 성분을 제거할 수 있고 기본파 성분의 크기를 최대로 출력할 수 있다.

  • PDF

New hysteresis current control for induction motor drive with NPC inverter (NPC 인버터에 의한 유도전동기 구동시스템의 새로운 히스테리시스 전류 제어기법)

  • 김춘삼;이병송
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 1999
  • A new current controlled PWM t'||'&'||'pound;rlmique with NPC(Neutral Point Qarll)ed) structure is IrOIX>Sed in this paper. A current controlled PWM technique with neutral-JXlint-cIamped pulse-width modulation inverter composed of main switching devices which operates as switch for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. The proposed current controller has a first and second current band The switching pattern will be made by the first current band. According to the second current band, the output state of the switching pattern is changed into positivee and negative state. This inverter output contains less hanronic content and lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Thbe induction machine drive with proposed technique is investigated by commputer simulation.

  • PDF

Control of Grid-Connected Power Conversion Systems using an Active NPC Inverter (Active NPC 인버터를 적용한 계통연계 전력변환 시스템의 제어)

  • Kim, Sung-Won;Seo, Dong-Woo;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.155-156
    • /
    • 2018
  • This paper presents a control method for grid-connected Active-NPC inverter systems. NPC (Neutral Point Clamped) is widely used in power conversion systems. NPC has a loss of switching elements and voltage imbalance. Active NPC has been proposed to overcome these drawbacks. ANPC changed the neutral diode to IGBT to reduce the switching loss. This paper modeled a grid-connected Acitve-NPC inverter systems and analyzed its performance. DSOGI PLL was used as a phase control method for precise control of grid link voltage. The proposed method is verified by PSIM simulation.

  • PDF

Natural Balancing of the Neutral Point Potential of a Three-Level Inverter with Improved Firefly Algorithm

  • Gnanasundari, M.;Rajaram, M.;Balaraman, Sujatha
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1306-1315
    • /
    • 2016
  • Modern power systems driven by high-power converters have become inevitable in view of the ever increasing demand for electric power. The total power loss can be reduced by limiting the switching losses in such power converters; increased power efficiency can thus be achieved. A reduced switching frequency that is less than a few hundreds of hertz is applied to power converters that produce output waveforms with high distortion. Selective harmonic elimination pulse width modulation (SHEPWM) is an optimized low switching frequency pulse width modulation method that is based on offline estimation. This method can pre-program the harmonic profile of the output waveform over a range of modulation indices to eliminate low-order harmonics. In this paper, a SHEPWM scheme for three-phase three-leg neutral point clamped inverter is proposed. Aside from eliminating the selected harmonics, the DC capacitor voltages at the DC bus are also balanced because of the symmetrical pulse pattern over a quarter cycle of the period. The technique utilized in the estimation of switching angles involves the firefly algorithm (FA). Compared with other techniques, FA is more robust and entails less computation time. Simulation in the MATLAB/SIMULINK environment and experimental verification in the very large scale integration platform with Spartan 6A DSP are performed to prove the validity of the proposed technique.

DC-Link Voltage Balance Control Using Fourth-Phase for 3-Phase 3-Level NPC PWM Converters with Common-Mode Voltage Reduction Technique

  • Jung, Jun-Hyung;Park, Jung-Hoon;Kim, Jang-Mok;Son, Yung-Deug
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.108-118
    • /
    • 2019
  • This paper proposes a DC-link voltage balance controller using the fourth-phase of a three-level neutral-point clamped (NPC) PWM converter with medium vector selection (MVS) PWM for common-mode voltage reduction. MVS PWM makes the voltage reference by synthesizing the voltage vectors that cannot generate common-mode voltage. This PWM method is effective for reducing the EMI noise emitted from converter systems. However, the DC-link voltage imbalance problem is caused by the use of limited voltage vectors. Therefore, in this paper, the effect of MVS PWM on the DC-link voltage of a three-level NPC converter is analyzed. Then a proportional-derivative (PD) controller for the DC-link voltage balance is designed from the DC-link modeling. In addition, feedforward compensation of the neutral point current is included in the proposed PD controller. The effectiveness of the proposed controller is verified by experimental results.

A carrier based neutral point balancing strategy for 3-level active-front-end rectifiers (3-레벨 AFE 정류기의 캐리어 기반 중성점 제어 기법)

  • Kang, Kyoung Pil;Kim, Ho-Sung;Cho, Jintae;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.212-213
    • /
    • 2017
  • In this paper is presented a pre-charging sequence for single-phase cascaded neutal-point-clamped(NPC) converters for capacitors voltage balancing. capacitor imbalance problem in pre-charge sequence is caused in cascaded NPC converter by its topology. the DC link voltage at each NPC converter module can be balanced by the proposed switching method. the design and performance of the proposed sequence are verified by simulation and experimental results using prototype.

  • PDF

Netral-Point Voltage Balancing Control Scheme for Stable Fault-Tolerant Operation of 3-Level ANPC Inverter (3레벨 ANPC 인버터의 안정적인 고장 허용 운전을 위한 중성점 전압 균형 제어 기법)

  • Lee, Jae-Woon;Park, Byoung-Gun;Kim, Ji-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.215-216
    • /
    • 2018
  • 본 논문에서는 Carrier-Based Pulse Width Modulation(CBPWM)을 사용한 Active Neutral Point Clamped (ANPC) 인버터의 안정적인 고장 허용 운전을 위한 중성점 전압 균형 제어 기법을 제안한다. 제안된 기법은 ANPC 인버터를 구성하고 있는 전력 반도체 스위치의 고장으로 인한 고장 허용 운전 시, 출력 특성이 저하되는 문제점을 해결하기 위해 스위칭 조합의 재구성과 기준 출력전압의 변조를 통한 중성점 전압 균형을 유지한다. 제안된 기법의 타당성은 RT-BOX를 통한 HIL 시뮬레이터를 이용하여 확인하였다.

  • PDF

Common-Mode Voltage Elimination with an Auxiliary Half-Bridge Circuit for Five-Level Active NPC Inverters

  • Le, Quoc Anh;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.923-932
    • /
    • 2017
  • This paper proposes a novel scheme which can compensate the common-mode voltage (CMV) for five-level active neutralpoint clamped (5L-ANPC) inverters, which is based on modifying the space vector pulse width modulation (SVPWM) and adding an auxiliary leg to the inverter. For the modified SVPWM, only the 55 voltage vectors producing low CMV values among the 125 possible voltage vectors are utilized, which varies over the three voltage levels of $-V_{dc}/12$, 0 V, and $V_{dc}/12$. In addition, the compensating voltage, which is injected into the 5L-ANPC inverter system to cancel the remaining CVM through a common-mode transformer (CMT) is generated by the additional NPC leg. By the proposed method, the CMV of the inverter is fully eliminated, while the utilization of the DC-link voltage is not decreased at all. Furthermore, all of the DC-link and flying capacitor voltages of the inverter are well controlled. Simulation and experimental results have verified the validity of the proposed scheme.

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF