• Title/Summary/Keyword: Neutral Surface

Search Result 524, Processing Time 0.026 seconds

A Study on the Measurement of the Normal Tracheal Length in Korea adults (한국성인의 기관 길이 측정에 관한 연구)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • v.28 no.8
    • /
    • pp.766-771
    • /
    • 1995
  • The trachea is defined as the airway from the inferior border of the cricoid cartilage to the top of the carinal spur. This paper would confirm the normal tracheal length of Korean adults through the actual measurement using the fiberoptic bronchoscopy. The subjects of this study were 25 patients, 13 males and 12 females between the age of 20 to 69 without abnormality on the neck, trachea, mediastinum and lung pharenchyme on the preoperative chest X-ray, who received the operations from the period of July to September, 1994. For those patients who had heart diseases, the cardiothoracic ratio was below 50%. The measurement was performed on the patients with endotracheal intubation under the general anesthesia in supine and neutral position. The tracheal length was calculated by the difference between the length from the tip of the endotracheal tube [E-tube to carina and to the needle which was inserted into the E-tube at the lower border of the palpated cricoid cartilage, by inserting the broncoscopy through the E-tube. The result was as follow : 1 The measured tracheal length for men was 11.8 0.2 cm[mean standard deviation and women was 10.5 0.3 cm, and that was longer than this [p<0.01 . The average was 11.2 1.0 cm and the standard error was 0.20 cm. 2 According to the correlation between the tracheal length to weight, height[Ht , age, and body surface area[BSA respectively, the Ht [p=0.003 , age [p=0.055 , and the BSA[p=0.017 were significant, while weight was not [p=0.314 . 3 From the regression analysis of the tracheal length[T.L. to the Ht, Age, and the BSA which were significant, the following equation was derived.i Ht : T.L.= -1.29 + 0.076 x Ht [P=0.003 ii Age: T.L.= 10.04 + 0.028 x Age [P=0.055 iii BSA : T.L.= 5.60 + 3.48 x BSA [P=0.017 iv In multi-regression : T.L. = -4.15 + 0.034 x Age + 0.085 x Ht [P=0.0002]

  • PDF

A Comparison among Latissimus Dorsi's Activities during Pull Up, Push Up and Lat Pull Down at Different Hand Grips and Grip Width Positions Based on Electromyographic(EMG) Activities (턱걸이, 팔굽혀펴기, 랫 풀다운 운동 시 잡는 방법과 넓이에 따른 넓은 등근의 근 활성도 비교)

  • Lee, Su-Hyun;Kim, Ju-O;Kim, Keun-Jo
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.2
    • /
    • pp.47-54
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the most effective exercise position of Latissimus dorsi's activities during Pull up, Push up and Lat pull down among few positions of hand grips(pronation, Supination and neutral grip) and grip widths(30cm, 60cm) based on EMG activities. Method: 10 healthy adults were participated in this study and the surface EMG activities of the Latissimus dorsi were measured during Pull up, Push up and Lat pull down exercise according to specific hand grip and grip width positions. The maximum and mean value of Latissimus dorsi's EMG activities at all positions were recorded and analysed by ONE-WAY REAPTED ANOVA. Results: The showed that the most Latissimus dorsi's activities is during Pull up exercise. Main results are as follows 1)maximum value: For Pull up, among all studied positions, Rt Latissumus dorsi, position of Supinated grip and 60cm grip width showed strongest muscle activation based on maximum EMG value. Statistical significance was assumed at p<.05. 2)mean value: For Pull up, among all studied positions, Both Latissimus dorsi, position of pronated grip and 60cm grip width showed strongest muscle activation based on mean EMG value. Statistical significance was assumed at p<.05. Conclusion: Therefore, taking the results of this study, Pull up exercise would be the best exercise of Latissimus dorsi's activation. It is recommended to do in pronated grip position and 60cm grip width during Pull up to make body fit.

Thermal Analysis of TRIO-CINEMA Mission

  • Yoo, Jae-Gun;Jin, Ho;Seon, Jong-Ho;Jeong, Yun-Hwang;Glaser, David;Lee, Dong-Hun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • Thermal analysis and control design are prerequisite essential to design the satellite. In the space environment, it makes satellite survive from extreme hot and cold conditions. In recent years CubeSat mission is developed for many kinds of purpose. Triplet Ionospheric Observatory (TRIO)-CubeSat for Ion, Neutral, Electron, MAgnetic fields (CINEMA) is required to weigh less than 3 kg and operate on minimal 3 W power. In this paper we describe the thermal analysis and control design for TRIO-CINEMA mission. For this thermal analysis, we made a thermal model of the CubeSat with finite element method and NX6.0 TMG software is used to simulate this analysis model. Based on this result, passive thermal control method has been applied to thermal design of CINEMA. In order to get the better conduction between solar panel and chassis, we choose aluminum 6061-T6 for the material property of standoff. We can increase the average temperature of top and bottom solar panels from $-70^{\circ}C$ to $-40^{\circ}C $ and decrease the average temperature of the magnetometer from $+93^{\circ}C$ to $-4^{\circ}C$ using black paint on the surface of the chassis, inside of top & bottom solar panels, and magnetometer.

Elastic-plastic formulation for concrete encased sections interaction diagram tracing

  • Fenollosa, Ernesto;Gil, Enrique;Cabrera, Ivan;Vercher, Jose
    • Steel and Composite Structures
    • /
    • v.19 no.4
    • /
    • pp.861-876
    • /
    • 2015
  • Composite sections design consists on checking that the point defined by axial load and bending moment keeps included within the surface enclosed by the section interaction curve. Eurocode 4 suggests a method for tracing this diagram based on the plastic stress distribution method. However curves obtained according to this criterion overvalue concrete encased sections bearing capacity, especially when axial force comes with high bending moment values, so a correction factor is required. This article proposes a method for tracing this diagram based on the strain compatibility method. When stresses on the section are integrated by considering the Navier hypothesis, the use of the materials nonlinear constitutive equations provides curves much more adjusted to reality. This process requires the use of rather complex software which might reveal as too complex for practitioners. Preserving the same criteria of an elastic-plastic stress distribution, this article presents alternative expressions to obtain the failure internal forces in five significant points of the interaction diagram having considered five different positions of the neutral axis. These expressions are simply enough for their practical application. Concordance of curves traced strictly relying on these five points with those obtained by computer assisted stress integration considering the strain compatibility method and even with Eurocode 4 weighted curves will be presented for three different cross-sections and two different concrete strengths, revealing very good results.

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

Disinfection Effects of Chlorine and Monochloramine on Campylobacter jejuni (Campylobacter jejuni에 대한 염소 및 Monochloramine의 살균효과)

  • 윤만석;오학식;김치경
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.6
    • /
    • pp.539-544
    • /
    • 1989
  • Campylobacter jejuni, bacterial agent causing human diarrhea, were studied for their disinfection effects with chlorine and monochloramine. The cells treated with the chemical agents were observed by scanning electron microscopy to know their morphological and structural changes. The proteins and DNA in the chemical-treated cells were also examined by gel electrophoresis for structural changes. When C. jejuni were chlorinated at concentrations of 0.5 and 1.0 mg/l for 15 minutes, the organisms were disinfected by 4 and 6 log, respectively. Those disinfection effects were higher at acidic pH, while lowered at neutral and alkaline values of pH. The effects of monochloramine were lower than those of chlorine at the game concentration for the same period of reaction time. The shapes of C. jejuni cells treated with the agents appeared to be deformed from spiral rod into spherical forms, showing some destruction in surface structure of the cells. Some of the proteins and DNA of the chlorinated cells did not appear in the gel electrophoresis when the chlorination was at concentration of 10 mg/l or higher.

  • PDF

콘크리트 재생 골재를 이용한 산성광산배수 중화처리

  • 김종범;오재일;정시열
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.71-74
    • /
    • 2001
  • AMB(Acid Mine Drainage), characterized as high concentration of metal & sulfate ions and low pH(2.0~4.0), is the world-wide problem wherever there is or has been mining activities. Though limestone has been generally used to neutralize AMD, There are metal hydroxide precipitation on the surface of limestone and excessive alkalinity formation which exceeds the regulation. In this research, concrete-recycled fine aggregate is selected for alternative neutralizing agent. Because fine recycled aggregate had more ANP than others in the preliminary research, the purpose of this research is to apply fine aggregate for AMD neutralization. Three columns packed with fine aggregates(2.5mm$O_3$) of it is calculated as 0.09(C-1), approximated 10% purity of limestone. Comparing with values of other columns(C-2: 0.01 and C-3: 0.01), there is variation of porosity and residence time induced from the precipitation of metal hydroxide. Consequently, 8 hours of HRT is enough to create adequate alkalinity and the function which could expect the variation of porosity(n) and residence time( $t_{R}$) should be applied to develop design function.lied to develop design function.

  • PDF

A Study on the Electrical Characteristic Analysis of c-Si Solar Cell Diodes

  • Choi, Pyung-Ho;Kim, Hyo-Jung;Baek, Do-Hyun;Choi, Byoung-Deog
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • A study on the electrical characteristic analysis of solar cell diodes under experimental conditions of varying temperature and frequency has been conducted. From the current-voltage (I-V) measurements, at the room temperature, we obtained the ideality factor (n) for Space Charge Region (SCR) and Quasi-Neutral Region (QNR) of 3.02 and 1.76, respectively. Characteristics showed that the value of n (at SCR) decreases with rising temperature and n (at QNR) increases with the same conditions. These are due to not only the sharply increased SCR current flow but the activated carrier recombination in the bulk region caused by defects such as contamination, dangling bonds. In addition, from the I-V measurements implemented to confirm the junction uniformity of cells, the average current dispersion was 40.87% and 10.59% at the region of SCR and QNR, respectively. These phenomena were caused by the pyramidal textured junction structure formed to improve the light absorption on the device's front surface, and these affect to the total diode current flow. These defect and textured junction structure will be causes that solar cell diodes have non-ideal electrical characteristics compared with general p-n junction diodes. Also, through the capacitance-voltage (C-V) measurements under the frequency of 180 kHz, we confirmed that the value of built-in potential is 0.63 V.

Effect of Taping on Lumbar Kinematics and Muscle Activities During Typing in Individuals With Nonspecific Chronic Low Back Pain

  • Kim, Hyun-A;Kwon, Oh-Yun;Ahn, Sun-Hee;Jeon, In-Cheol;Choung, Sung-Dae
    • Physical Therapy Korea
    • /
    • v.22 no.1
    • /
    • pp.93-102
    • /
    • 2015
  • Prolonged sitting can contribute to low back pain. The lumbar taping can be applied to correct the sitting posture. This study aimed to investigate the effect of lumbar taping on lumbar kinematics and the muscle activities of multifidus (MF) and internal oblique in the individuals with nonspecific chronic low back pain (NSCLBP) as they type for 30 minutes. Nineteen subjects with NSCLBP (9 people in non taping group and 10 people in taping group) were recruited. Lumbar taping was applied to the taping group before typing. Both groups started typing in a neutral sitting position with their feet on the floor. The change of posture and S2 posterior tilting (S2P) were measured to investigate kinematic data. Three sensors were attached on T12, L3, and S2 to identify the change of posture. Surface electromyography was used to measure the muscle activities. Palpation meter was used to standardize the angle of pelvic tilt in sagittal plane before typing. All instruments were used to measure each data before and after typing. Independent t-test was used to compare the changing values of lumbar kinematics and muscle activities before and after typing between both groups. The changing values of S2P and change of posture of L3 and S2 were significantly smaller in the taping group compared to the non taping group (p<.05). The changing value of muscle activities of MF between before and after typing was significantly smaller in the taping group compared to the non taping group (p<.05). In conclusion, the lumbar taping during the 30-minute typing task can be applied to maintain correct sitting posture in the lumbar and pelvis and to maintain activation of MF.

Comparison of the Foot Muscle EMG and Medial Longitudinal Arch Angle During Short Foot Exercises at Different Ankle Position

  • Yoon, Hyeo-bin;Kim, Ji-hyun;Park, Joo-hee;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.46-53
    • /
    • 2017
  • Background: The MLA is supported by both the abductor hallucis (ABH) and the extrinsic muscles. Insufficient muscular support may lower the MLA when the body's weight is applied to the foot. The short foot exercise (SFE) is effective in increasing the height of the MLA for people with flat feet. Most of the research related to the SFE has simply evaluated the efficiency of the exercise using enhanced ABH electromyography (EMG) activation. Since the tibialis anterior (TA), peroneus longus (PER), and ABH are all involved in supporting the MLA, a new experiment design examining the EMG of the selected muscles during SFE should be applied to clarify its effect. Objects: Therefore, this study aimed to clarify the effect of the SFE in different ankle position on the MLA angle and the activation of both the intrinsic and extrinsic muscles and to determine the optimal position. Methods: 20 healthy subjects and 12 subjects with flat feet were recruited from Yonsei University. The surface EMG and camera were used to collect muscle activation amplitude of TA, PER, and ABH and to capture the image of MLA angle during SFE. The subjects performed the SFE while sitting in three different ankle positions-neutral (N), dorsiflexion (DF) at 30 degrees, and plantar flexion (PF) at 30 degrees. Results: ABH EMG amplitudes were significantly greater in N and DF than in PF (p<.05). Muscle activation ratio of TA to ABH was the lowest in PF (p<.05). MLA angle in both groups significantly decreased in PF (p<.01). The TA and ABH was activated at the highest level in DF. However, in PF, subjects significantly activated the ABH and PER with relatively low activation of TA. Conclusion: Therefore, researchers need to discuss which SFE condition most effectively use the arch support muscle for flat foot.