• 제목/요약/키워드: Neutral Current

검색결과 485건 처리시간 0.025초

매크로 파라메트릭 방법론은 이용한 CAD 모델의 교환 (Exchange of CAD Models Using Macro Parametric Approach)

  • 문두환;한순흥
    • 한국CDE학회논문집
    • /
    • 제6권4호
    • /
    • pp.254-262
    • /
    • 2001
  • It is not possible to exchange parametric information of CAD (Computer Aided Design) models based on the current version of STEP (Standard leer the Exchange of Product model data). The design intent can be lost during the STEP transfer of CAD models. The ISO Parametrics Group has proposed the SMCH (Solid Model Construction History) schema in June 2000 that includes structures fur exchange of parametric information. This paper proposes the macro parametric approach that is intended to provide capabilities to transfer parametric information. In this approach, CAD models are exchanged in the form of macro files. The macro file contains user commands which are used in the modeling phase. To exchange CAD models using the macro parametric approach, modeling commands of commercial CAD systems are analyzed. Those commands are classified by the grouping method suggested by Bill Anderson. As a neutral file format, a standard modeling commands set has been defined. Mapping relations between the standard modeling commands set and the native modeling commands set of commercial CAD systems are defined.

  • PDF

제품 정보의 검색에 온톨로지 활용 방법 (A Method of Applying Ontology for Product Information Search)

  • 최무라;유상봉
    • 한국CDE학회논문집
    • /
    • 제6권4호
    • /
    • pp.229-235
    • /
    • 2001
  • As the networks (i.e., intranet and internet) proliferate all over the world, it is inevitable to move some (or all) of the enterprise activities into virtual spaces. Differently from business data, product data have complex semantics and thus are not properly exchanged among different application programs. Even though some neutral formats of product data have been developed by standard organizations, exchanging them among various application programs still needs the comprehensive understanding of the complex semantics. Recently, it is widely recognized that capturing more knowledge is the next step to overcome the current difficulties on sharing product data. In this paper, we utilize the ontology concept in order to facilitate information search far product data in the internet environment. A prototype of search system implemented using the ontology for automobile product data is presented.

  • PDF

3-Level T-type Inverter Operation Method Using Level Change

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.263-269
    • /
    • 2018
  • In this study, a selective inverter operation between a 2-level voltage source converter (VSC) and a 3-level T-type VSC (3LT VSC) is proposed to improve the efficiency of a 3LT VSC. The 3LT VSC topology, except for its neutral-point switches, has similar operations as that of the 2-level VSC. If an operation mode is changed according to efficiency, the efficiency can be improved because efficiencies of each methods are depending on current and MI (Modulation Index). The proposed method calculates the power losses of the two topologies and operates as the having lower losses. To calculate the losses, the switching and conduction losses based on the operation mode of each topology were analyzed. The controller determined the operation mode of the 2- or 3-level VSC based on the power loss calculated during every cycle. The validity of the proposed control scheme was investigated through simulation and experiments. The waveform and average efficiency of each method were compared.

2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상 (Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters)

  • 김영신;이동춘;석줄기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

범용파워모듈로 구성된 보조 공진형 인버터의 특성 해석 (Modeling of auxiliary resonant inverter circuit using mediocrity power module)

  • 이상현;문상필;권순걸;이현우;서기영;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.9-11
    • /
    • 2002
  • These days, electromagnetic radiation noise and switching losses of static converter become harmful. Many resonant inverters with radiation techniques solve their such problems. Auxiliary Resonant Commutated Pole Inverter (ARCP) was proposed. but it has two demerits. In circuit configuration. It isn't constructed by 2 in 1 IGBT modules, Besides, control is complicated because of neutral point voltage control and boost. current control. This paper proposes a new auxiliary resonant inverter which solved two demerits. In addition, it deals efficiency which compared with hard switching inverter and result of separation of power loss

  • PDF

H-Bridge VSC with a T-Connected Transformer for a 3-Phase 4- Wire Voltage and Frequency Controller of an Isolated Asynchronous Generator

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.43-50
    • /
    • 2009
  • This paper deals with a novel solid state controller (NSSC) for an isolated asynchronous generator (IAG) feeding 3-phase 4-wire loads driven by constant power prime movers, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of the asynchronous generator. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 2-leg voltage source converters (CC- VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The neutral point of the load is created using aT-configuration of the transformers. The IAG system is modeled in MATLAB along with Simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of the isolated generating system consisting of NSSC and IAG driven by uncontrolled pico hydro turbine and feeding 3-phase 4-wire loads.

Load Switching 기법을 이용한 중성선 전류 저감기법에 관한 연구 (A Study on the Neutral Current Reduction using Load Switching Method)

  • 박건우;이상봉;김철환;정창수;유연표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.665-666
    • /
    • 2007
  • 본 논문은 배전계통에서 load switching 기법을 이용한 중성선 전류저감 방법에 대한 연구결과를 제시하였다. 본 방법의 동작은 중성선과 상전류의 변화에 의해 결정되며, 저감 방법에 대한 구성은 실효치 변환부, 3상전류 비교부, 최적조건 선택부 그리고 스위치 제어부로 총 4부분으로 구성되어있으며, 각 부분은 EMTP/MODELS를 이용하여 구현하였다.

  • PDF

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

Comparison of Two Reactive Power Definitions in DFIG Wind Power System under Grid Unbalanced Condition

  • Ha, Daesu;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.213-214
    • /
    • 2014
  • This paper compares two instantaneous reactive power definitions in DFIG wind turbine with a back-to-back three-level neutral-point clamped voltage source converter under unbalanced grid conditions. In general, conventional definition of instantaneous reactive power is obtained by taking an imaginary component of complex power. The other definition of instantaneous reactive power can be developed based on a set of voltages lagging the grid input voltages by 90 degree. A complex quantity referred as a quadrature complex power is defined. Proposed definition of instantaneous reactive power is derived by taking a real component of quadrature complex power. The characteristics of two instantaneous reactive power definitions are compared using the ripple-free stator active power control algorithm in DFIG. Instantaneous reactive power definition based on quadrature complex power has a simpler current reference calculation control block. Ripple of instantaneous active and reactive power has the same magnitude unlike in conventional definition under grid unbalance. Comparison results of two instantaneous reactive power definitions are verified through simulation.

  • PDF

배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구 (A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage)

  • 곽동걸;박동훈;박영직;정도영;김동균
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF