• Title/Summary/Keyword: Neutral Angle

Search Result 165, Processing Time 0.026 seconds

Effects of Balance Training through Various Ankle Inclination on Dynamic Balance in Healthy Adults (다양한 발목 경사를 통한 균형 훈련이 건강한 성인의 동적 균형에 미치는 영향)

  • Kim, Nuri;Kim, Kangmi;Lee, Jeongeun;Lee, Hakyeong;Cha, Yuri
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.3
    • /
    • pp.61-67
    • /
    • 2018
  • Background: The purpose of this study is to report the effect of balance training through various ankle inclination on dynamic balance in healthy adults. Methods: This study was participated in 20 healthy subjects. Twenty healthy adults were randomly divided into 10 ankle inclination group and 10 flat group, 3 kinds of exercised were performed in $30^{\circ}$ of the plantar flexion, $0^{\circ}$ of the neutral angle and $30^{\circ}$ of the dorsiflexion. Above 3 kinds of exercises were also performed in the flat group. Dynamic balance of each group was evaluated using a Figure-of-8 hop test, Up-down hop test, and Functional reach test before and after the experiment. Results: In the ankle inclination, the post-experiment showed a significant difference in Figure-of-8 hop test, Up-down hop test, and Functional reach test in comparison to pre-experiment(p<.05). Conclusion: The exercise applied in the ankle inclination is effective in improvement of the dynamic balance.

The Impact of Emotion on Focused Attention in a Flanker Task (수반자극과제에서 정서가 초점주의에 미치는 영향)

  • Park, Tae-Jin;Park, Sun-Hee
    • Korean Journal of Cognitive Science
    • /
    • v.22 no.4
    • /
    • pp.385-404
    • /
    • 2011
  • We examined how emotional background stimuli influence focused attention in a flanker task. An IAPS picture was presented for 1,000ms in advance, then a target and two flanker letters were presented against the IAPS picture for 200ms(Experiment 1). The flanking stimuli were simultaneously presented on the left and right sides of the target stimulus with distance of $0.5^{\circ}C$, $1^{\circ}C$, or $1.5^{\circ}C$ visual angle. We investigated the flanker compatibility effect that identification of target would be faster when they were flanked by identical(compatible) stimuli than when they were flanked by different(incompatible) stimuli. Results of Experiment 1 revealed that the flanker compatibility effect depended not only on the distance of flankers but also on the valence of a background IAPS pictures. Positive and neutral pictures showed distance effect that the flanker compatibility effect was decreased as the farther the distance was, while negative pictures showed no di stance effect. Positive and neutral pictures showed compatibility effects at all distance conditions, but negative pictures didn't showed compatibility effect at $1.5^{\circ}C$ distance condition. In Experiment 2, the SOA(Stimulus Onset Asynchrony) between the picture and the stimuli of flanker task was manipulated. The flanking stimuli were presented simultaneously on the left and right sides of the target stimulus with a distance of either $0.5^{\circ}C$ or $1.5^{\circ}C$ visual angle. The results of Experiment 2 showed that flanker compatibility effect depends on SOA. At long SOA(2800ms), negative pictures showed no distance effect, but positive or neutral pictures did. All valence conditions of background pictures showed compatibility effects at $0.5^{\circ}C$ distance condition, but didn't showed compatibility effect at $1.5^{\circ}C$ distance condition. At short SOA(100ms), all valence conditions of background pictures showed distance effect, and showed compatibility effects with the exception of negative background pictures at $1.5^{\circ}C$ distance condition. These findings suggest that the scope of visual attention becomes narrower when viewing negative emotional stimuli and becomes broadened when viewing positive emotional stimuli. The narrowed scope of attention in negative emotion lasts longer, while the broaden scope of attention in positive emotion lasts shorter.

  • PDF

Effects of Hip Internal Rotation on Knee Extensor and Hip Abductor Electromyographic Activity During Stair Up and Down (계단 오르고 내리기시 엉덩관절 내회전이 무릎관절 폄근과 엉덩관절 벌림근 근활성도에 미치는 영향)

  • Oh, Jae-Seap;Kwan, Oh-Yun;Yi, Chung-Hwi;Jean, Hye-Sean
    • Physical Therapy Korea
    • /
    • v.15 no.2
    • /
    • pp.54-63
    • /
    • 2008
  • The purpose of this study was to examine the effect of the hip internal rotation on knee extensor and hip abductor electromyographic (EMG) activity during stair up and stair down mobility. Eighteen healthy subjects were recruited. All subjects performed stair up and down movements on a step of 30cm height while maintaining the hip in neutral (condition 1) and hip in internal rotation (condition 2). Surface EMG activity was recorded from five muscles (gluteus maximus, vastus lateralis (VL), vastus medialis oblique (VMO), posterior gluteus medius (Gmed), and tensor fascia latae (TFU)) and hip internal rotation angle was measured using a three dimensional motion analysis system The time period for stair up and down was normalized using the MatLab 6.5 program, and EMG activity was normalized to the value of maximal voluntary isometric contraction (%MVIC). The EMG activities according to the hip rotation (neutral or internal rotation) during the entire time period of stair up and down in each phase were compared using a paired t-test. During the entire period of stair up, the EMG activities of VL and TFL in condition 2 were significantly greater than in condition 1 (p<.05). During the entire period of stair down, the EMG activities of VL and TFL in condition 2 were significantly greater than in condition 1 (p<.05). However, the EMG activities of the other muscles were not significantly different between the conditions (p>.05). These results suggest that the stair up and down maintaining hip internal rotation was could be a contributing factor on patellar lateral tracking.

  • PDF

Study on Softness of an EO Adducted Amine Oxide Zwitterionic Surfactant (EO가 부가된 아민 옥사이드 양쪽성 계면활성제의 유연력에 관한 연구)

  • Kim, JiSung;Mo, DaHee;Lee, JinSun;Park, JunSeok;Han, DongSung;Lim, JongChoo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.960-968
    • /
    • 2012
  • In this study, the measurement of physical properties of 3 different ethylene oxide adducted zwitterionic surfactants were measured such as critical micelle concentration, surface tension, interfacial tension, contact angle, viscosity and foam stability. Also, the dual function characteristics of the zwitterionic surfactants were investigated by determining an isoelectric point, which were obtained using zeta potential measurement and QCM (quartz crystal microbalance) experiments. The isoelectric point of the synthesized zwitterionic surfactant determined by zeta potential measurement was close to that obtained by QCM experiment and both results have shown almost the same trend as that determined by the frictional property measured using an automated mildness tester. In particular, it has been observed that all three surfactants used during this study provide better softening effect at a pH of neutral condition than at an acidic or an alkaline condition. This result indicates that the synthesized surfactants act as a cationic surfactant at a pH of neutral condition and thus provide good softening effect during a rinsing cycle in the detergency process.

Measurement of an Isoelectric Point and Softness of a EO-PO Adducted Zwitterionic Surfactant (EO-PO가 부가된 양쪽성 계면활성제의 등전점 및 유연력 측정에 관한 연구)

  • Lim, JongChoo;Mo, DaHee;Lee, JinSun;Park, JunSeok;Han, DongSung
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.455-463
    • /
    • 2012
  • In this study, the measurement of physical properties of ethylene oxide-propylene oxide adducted zwitterionic surfactants were measured such as critical micelle concentration, surface tension, interfacial tension, contact angle, viscosity and foam stability. Also, the dual function characteristics of a zwitterionic surfactant were investigated by determining an isoelectric point, which were obtained using zeta potential measurement and QCM (quartz crystal microbalance) experiments. The isoelectric point of DEP-OSA82-AO zwitterionic surfactant determined by zeta potential measurement was close to that obtained by QCM experiment and both results have shown almost the same trend as that determined by the frictional property measured using an automated mildness tester. In particular, it has been observed that DEP32-OSA82-AO and DEP34-OSA82-AO surfactants provide better softening effect at a pH of acidic or neutral condition than at an alkaline condition. This result indicates that both surfactants act as a cationic surfactant at a pH of acidic or neutral condition and thus provide good softening effect during a rinsing cycle in the detergency process.

Surface Characterization of NF membranes for Hardness Removal and Its Implications to Fouling Mechanisms (경도제거용 나노여과막의 표면 특성 분석 및 막오염기작 연구)

  • Ham, Sangwoo;Kim, Youngjin;Kim, Chunghwan;Shon, Hokyong;Hong, Seungkwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.559-567
    • /
    • 2013
  • In recent years, NF (nanofiltration) membrane has been receiving great attention for hardness removal and has begun to replace traditional lime soda ash softening process, particularly in Florida, USA, mainly due to less sludge production and easy operation. This study aimed to provide detailed surface characteristics of various commercial NF membranes by performing sophisticated surface analysis, which would help more fundamentally understand the performance of NF membranes. More specifically, a total of 7 NF membranes from top NF/RO manufacturers in the world were examined for basic performance tests, surface analysis, and fouling potential assessment. The results demonstrated that NF membranes are classified into two groups in terms of surface zeta potential; they are highly negatively charged ones, and neutral and/or less negatively charged ones. Their hydrophobicities, measured by contact angle, varied from hydrophilic to slightly hydrophobic ones. The AFM measurements showed various surface roughness, ranging from 23 nm (smooth) to 162 nm (rough) of average peak height. Lab-scale fouling experiments were performed using feedwater obtained from conventional water treatment plants in the province of Korea, and their results attempted to correlate to surface characteristics of NF membranes. However, unlike typical RO membranes, no clear correlation was found in this study, indicating that fouling mechanisms of NF membrane may be different from those of typical RO membranes, and both cake deposition and pore blocking mechanisms should be considered simultaneously.

Development of CINEMA Mission Uplink Communication System

  • Yoon, Na-Young;Yoon, Se-Young;Kim, Yong-Ho;Yoon, Ji-Won;Jin, Ho;Seon, Jong-Ho;Chae, Kyu-Sung;Lee, Dong-Hun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.33-40
    • /
    • 2012
  • Triplet Ionospheric Observatory (TRIO) CubeSatforIon, Neutral, Electron MAgneticfields (CINEMA) is a CubeSat with the weight 3 kg that will be operated in the orbit conditions of about 800 km altitude and $90^{\circ}$ inclination angle, using the S-band and ultra-high frequency (UHF)-band communication frequencies. Regarding the communication antenna loaded on the satellite, the two patch antennas has the downlink function in the S-band, whereas the two whip antennas has the function to receive the command sent by the ground station to the satellite in the UHF-band. The uplink ground station that communicates through the UHF-band with the CINEMA satellite was established at Kyung Hee University. The system is mainly composed of a terminal node controller, a transceiver, and a helical antenna. The gain of the helical antenna established at the Kyung Hee University ground station was 9.8 dBi. The output of the transceiver was set to be 5 W (6.9 dB) for the communication test. Through the far-field test of the established system, it was verified that the Roman characters, figures and symbols were converted into packets and transmitted to the satellite receiver in the communication speed of 9,600 bps.

JProtein : A Protein Structure Viewer based on Java3D Technology (JProtein : Java3D 기법을 이용한 단백질 구조 뷰어)

  • Moon Nam-Doo;Byun Sang-Hee;Kim Jin-Hong;Han In-Seob;Lee Myung-Joon
    • The KIPS Transactions:PartD
    • /
    • v.11D no.7 s.96
    • /
    • pp.1517-1526
    • /
    • 2004
  • Entering the post genome era with an increasing amount of protein data available in public databases, the study of tertiary structure of pro-teins has been artively in progress. To analyze the structure of a protein effectively, it is necessary to visualize the tertiary structure of a protein. Rececntly, many visualization tools based on Java technology have been developed to visualize a protein whose structure has been known. In this paper, we describe a new protein visualization system, named JProtein. It is designed to be an easy-to-use, platform neutral melocular visualization tool. The JProtein system is developed using Java3D technology. Java3D is an API providing a programming interface for 3D representations. The system informs us the angle and the distance of the interacting atoms in amino acids which are visualized, providing several 3D representation models of a protein molecule. In particular, the JProtein system presents synchronous stereo view as well as asynchronous one.

Effect of Taping on Lumbar Kinematics and Muscle Activities During Typing in Individuals With Nonspecific Chronic Low Back Pain

  • Kim, Hyun-A;Kwon, Oh-Yun;Ahn, Sun-Hee;Jeon, In-Cheol;Choung, Sung-Dae
    • Physical Therapy Korea
    • /
    • v.22 no.1
    • /
    • pp.93-102
    • /
    • 2015
  • Prolonged sitting can contribute to low back pain. The lumbar taping can be applied to correct the sitting posture. This study aimed to investigate the effect of lumbar taping on lumbar kinematics and the muscle activities of multifidus (MF) and internal oblique in the individuals with nonspecific chronic low back pain (NSCLBP) as they type for 30 minutes. Nineteen subjects with NSCLBP (9 people in non taping group and 10 people in taping group) were recruited. Lumbar taping was applied to the taping group before typing. Both groups started typing in a neutral sitting position with their feet on the floor. The change of posture and S2 posterior tilting (S2P) were measured to investigate kinematic data. Three sensors were attached on T12, L3, and S2 to identify the change of posture. Surface electromyography was used to measure the muscle activities. Palpation meter was used to standardize the angle of pelvic tilt in sagittal plane before typing. All instruments were used to measure each data before and after typing. Independent t-test was used to compare the changing values of lumbar kinematics and muscle activities before and after typing between both groups. The changing values of S2P and change of posture of L3 and S2 were significantly smaller in the taping group compared to the non taping group (p<.05). The changing value of muscle activities of MF between before and after typing was significantly smaller in the taping group compared to the non taping group (p<.05). In conclusion, the lumbar taping during the 30-minute typing task can be applied to maintain correct sitting posture in the lumbar and pelvis and to maintain activation of MF.

Radiographic Characteristics and the Clinical Results of the Operative Treatment of M$\ddot{u}$ller-Weiss Disease (뮐러-와이스 병의 방사선학적 특징 및 수술적 치료의 결과)

  • Choi, Hong-Joon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.100-105
    • /
    • 2013
  • Purpose: To present radiographic characteristics and report the clinical results of the operative treatment of M$\ddot{u}$ller-Weiss disease. Materials and Methods: This is a retrospective study including 13 patients, 14 feet who had been operated for M$\ddot{u}$ller-Weiss disease between April 2006 and December 2011. Osteoarthritis of the peri-navicular joints were radiographically evaluated. Various range of peri-navicular fusion and joint-preserving surgeries according to patients' symptoms and radiographic findings were done. The clinical results were evaluated by American Orthopaedics Foot and Ankle Society (AOFAS) midfoot scale and visual analogue scale (VAS). Results: On radiographs, osteoarthritic changes were presented at talonavicular joint in 11 cases, calcaneocuboid joint in 7 cases, subtalar joint in 6 cases, naviculo-cuneiform joint in 1 case. The mean anteroposterior talocalcaneal angle was 16.6 degrees. On hindfoot alignment view, 6 cases were varus, 5 cases were neutral and 3 cases were valgus alignment. Fusion comprised 6 cases in triple fusion, 1 case in talonavicular-cuneiform fusion, 2 cases in talonavicualr fusion and 1 case in talonavicular & calcaneocuboid fusion. Joint-preserving surgeries were bony fragment excision of the lateral part of navicular & medial displacement calcaneal osteotomy in 1 case, bony spur excision of talonavicular joint in 1 case and medial displacement calcaneal osteotomy in 2 cases. The postoperative AOFAS and VAS score were improved significantly (p=0.000, p=0.000). Conclusion: In cases of M$\ddot{u}$ller-Weiss disease without osteoarthritic changes at peri-navicular joints, fragment excision of navicular, bony spur excision with or without medial displacement calcaneal osteotomy were effective operative treatments.