JSTS:Journal of Semiconductor Technology and Science
/
제14권5호
/
pp.658-665
/
2014
The neural stimulators have been employed to the visual prostheses system based on the functional electrical stimulation (FES). Due to the size limitation of the implantable device, the smaller area of the unit current driver pixel is highly desired for higher resolution current stimulation system. This paper presents a 16-channel compact current-mode neural stimulator IC with digital to analog converter (DAC) sharing scheme for artificial retinal prostheses. The individual pixel circuits in the stimulator IC share a single 6 bit DAC using the sample-and-hold scheme. The DAC sharing scheme enables the simultaneous stimulation on multiple active pixels with a single DAC while maintaining small size and low power. The layout size of the stimulator circuit with the DAC sharing scheme is reduced to be 51.98 %, compared to the conventional scheme. The stimulator IC is designed using standard $0.18{\mu}m$ 1P6M process. The chip size except the I/O cells is $437{\mu}m{\times}501{\mu}m$.
JSTS:Journal of Semiconductor Technology and Science
/
제13권1호
/
pp.79-86
/
2013
We describe a neural stimulator front-end with arbitrary stimulation waveform generator and adaptive supply regulator (ASR) for visual prosthesis. Each pixel circuit generates arbitrary current waveform with 5 bit programmable amplitude. The ASR provides the internal supply voltage regulated to the minimum required voltage for stimulation. The prototype is implemented in $0.35{\mu}m$ CMOS with HV option and occupies $2.94mm^2$ including I/Os.
Chronic postoperative inguinal pain (CPIP) is a major complication after inguinal herniorrhaphy. We report the treatment of CPIP using ultrasonography-combined with nerve stimulator for injection of the genitofemoral nerve (GFN). A 59-year-old man underwent laparoscopic herniorrhaphy and presented with numbness from the inguinal region to the scrotum after operation. In the pain clinic, ultrasonography-guided GFN block and pharmacological treatments had little effect. Six month after operation, patient was referred to the Department of Physical Medicine and Rehabilitation, and ultrasonography-combined with nerve stimulator for GFN injection underwent to enhance the accuracy of neural approach. The induction of scrotal contraction and paresthesia on the GFN distribution was monitored by nerve stimulator and local anesthetic was injected. After the block, pain relief lasted for 6 months without analgesic use. Ultrasonography-combined with nerve stimulator is an effective approach to treat CPIP as it enhances precise localization and injection of small peripheral nerve like GFN.
Park, Byeonggyu;Yun, Tae-Gwon;Lee, Kyongsu;Kang, Jin-Ku
JSTS:Journal of Semiconductor Technology and Science
/
제17권1호
/
pp.120-128
/
2017
This paper describes a neural stimulation system that employs an inductive coupling link to transfer power and data wirelessly. For the reliable data and power delivery, a self-referenced amplitude-shift keying (ASK) demodulator and a wide-range voltage regulator are suggested and implemented in the proposed stimulator system. The prototype fabricated in 0.35 um BCD process successfully transferred 1.2 Kbps data bi-directionally while supplying 4.5 mW power to internal MCU and stimulation block.
본 논문에서는 신경 관련 인공 전자기기를 위한 신경 자극 집적회로를 $0.18-{\mu}m$ 표준 CMOS 반도체 공정을 이용하여 설계하였다. 제안 된 신경 자극 회로는 12.8-V 전원을 사용하면서 $10-k{\Omega}$의 부하에 최대 1 mA의 전류까지 전달이 가능하다. 표준 CMOS 공정 기술로 구현을 위해서 저전압 트랜지스터만을 이용하여 설계를 하였고, 고전압에서의 안정적인 동작을 위하여 트랜지스터 스태킹 기술을 적용하였다. 또한, 신경 자극 동작 후 전하 잔여량이 남아 있지 않도록 active charge balancing회로를 포함하였다. 제안 된 단일 채널 자극 집적회로의 경우 디지털-아날로그 변환기, 전류 출력 드라이버, 레벨 시프터, 디지털 제어 부분, 그리고 active charge balancing 회로까지 모두 포함하여 전체 칩 레이아웃 면적은 $0.13mm^2$을 차지하며, 다중 채널 방식의 신경 자극 기능의 체내 이식용 인공 전자기기 시스템에 적용을 하는데 적합하다.
체내 통신은 인체를 통신 매체로 하여 신호를 전송하는 무선 통신 방식이다. 체내 통신 방식은 체내와 송수신 시스템 그리고 외부 접지를 통한 하나의 전류 패스를 형성함으로써 이루어지는데, 인공 와우와 같은 신경 보철 장치의 경우 피하에 이식되어 있기 때문에 외부 접지를 사용하기 어렵다. 따라서 본 논문에서는 이와 같은 접지의 영향을 받지 않는 체내 통신을 제안하여 신경 보철 장치를 위한 시스템을 개발하였다. 개발된 시스템은 이식된 보철 장치의 체내에 위치한 전극으로의 신호 전송이 가능하도록 설계되었다. 효과적인 통신을 위하여 실험동물의 피부 위 실험 및 피하 실험을 통해 신호 전송 특성을 조사하였으며, 피부 위 실험의 경우 약 10MHz, 피하 실험의 경우 약 3MHz 이상의 주파수 대역에서 최대 전송 이득을 가지는 것을 확인하였다. 본 시스템은 데이터 전송률 480kbps를 갖는 pulse width modulation (PWM) 방식을 사용한 인공 와우용 내부 전류 자극기에 적용하여 그 성능을 입증하였다.
Park, Jeong Hoan;Shim, Shinyong;Jeong, Joonsoo;Kim, Sung June
JSTS:Journal of Semiconductor Technology and Science
/
제17권1호
/
pp.35-41
/
2017
We propose a novel multi-photodiode array (MPDA) based retinal implant IC with on/off stimulation strategy for a visual prosthesis with improved spatial resolution. An active pixel sensor combined with a comparator enables generation of biphasic current pulses when light intensity meets a threshold condition. The threshold is tuned by changing the discharging time of the active pixel sensor for various light intensity environments. A prototype of the 30-channel retinal implant IC was fabricated with a unit pixel area of $0.021mm^2$, and the stimulus level up to $354{\mu}A$ was measured with the threshold ranging from 400 lx to 13120 lx.
Stroke is the second most significant disease leading to death in Korea. The conventional therapeutic approach is mainly based on physical training, however, it usually provides the limited degree of recovery of the normal brain function. The electric stimulation therapy is a novel and candidate approach with high potential for stroke recovery. The feasibility was validated by preliminary rat experiments in which the motor function was recovered up to 80% of the normal performance level. It is thought to improve the neural plasticity of the nerve tissues around the diseased area in the stroked brain. However, there are not so much research achievements in the electric stimulation for stroke recovery as for the Parkinson's disease or Epilepsy. This study aims at the developments of a wireless variable pulse generator using ZigBee communication for future implantation into human brain. ZigBee is widely used in wireless personal area network (WPAN) and home network applications due to its low power consumption and simplicity. The developed wireless pulse generator controlled by ZigBee can generate various electric stimulations without any distortion. The electric stimulation includes monophasic and biphasic pulse with the variation of shape parameters, which can affect the level of recovery. The developed system can be used for the telerehabilitation of stroke patient by remote control of brain stimulation via ZigBee and internet. Furthermore, the ZigBee connection used in this study provides the potential neural signal transmission method for the Brain-Machine Interface (BMI).
Kim Sung June;Jung Hum;Yu Young Suk;Yu Hyeong Gon;Cho Dong il;Lee Byeong Ho;Ku Yong Sook;Kim Eun Mi;Seo Jong Mo;Kim Hyo kyum;Kim Eui tae;Paik Seung June;Yoon Il Young
한국가시화정보학회:학술대회논문집
/
한국가시화정보학회 2002년도 마이크로/바이오 가시화기술부문 학술강연회
/
pp.51-78
/
2002
A number of research groups worldwide are studying electronic implants that can be mounted on retinal optic nerve/visual cortex to restore vision of patients suffering from retinal degeneration. The implants consist of a neural interface made of biocompatible materials, one or more integrated circuits for stimuli generation, a camera, an image processor, and a telemetric channel. The realization of these classes of neural prosthetic devices is largely due to the explosive development of micro- and nano-electronics technologies in the late $20^{th}$ century and biotechnologies more recently. Animal experiments showed promise and some human experiments are in progress to indicate that recognition of images can be obtained and improved over time. We, at NBS-ERC of SNU, have started our own retinal implant project in 2000. We have selected polyimide as the biomaterial for an epi-retinal stimulator. In-vitro and in-vivo biocompatibility studies have been performed on the electrode arrays. We have obtained good affinity to retinal pigment epithelial cells and no harmful effect. The implant also showed very good stability and safety in rabbit eye for 12 weeks. We have also demonstrated that through proper stimulation of inner retina, meaning vision can be obtained.
본 논문에서는 뉴로-퍼지 방법을 이용한 한방 맥진 및 양도락 진단 알고리즘을 제안하고 DSP보드를 중심으로 한 실시간 진단 시스템을 구현한다. 맥진은 환자의 손목에 있는 촌관척부에 부착한 맥진 Probe를 통해 맥진카드의 3 채널로 신호가 입력되도록 하여, 1차적으로 좌부맥, 좌침맥, 우부맥, 우침맥으로 나누어 촌관척 3부분을 동시에 실험하고, 2차적으로는 촌관척 중 1부분씩 개별적으로도 실험을 행할 수 있도록 한다. 실제 실험을 통하여 어느 맥진 Probe로도 맥진 신호가 세밀하게 검출됨을 확인한다. 양도락 진단에서는 전기자극기에서 발생된 펄스를 인체의 일정부위에 주입하면 12경맥의 대표측정점에 부착된 전극을 통해 응답신호를 검출해 내도록 한다. 실험은 ① 1채널씩 검출, ② 2채널(좌, 우)씩 검출, ③ 6채널(좌수, 우수, 좌족, 우족)씩 4단계로 검출, ④ 24채널 동시 검출 후, 1차적으로 퍼지진단을 행하고, 2차적으로 퍼지진단값을 신경회로망의 입력으로 이용하여 신경회로망 훈련을 행하였다. 그리고 임의의 환자에게서 측정한 검출값을 곧바로 기 훈련 된 양도락 신호의 패턴인식을 행하여 양도락 신호의 뉴로-퍼지 진단이 잘 수행됨을 확인하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.