• Title/Summary/Keyword: Network Switch

Search Result 632, Processing Time 0.027 seconds

A Robust Route Maintenance Scheme Considering Node Mobility in Wireless Ad-hoc Networks (무선 Ad-hoc 네트워크에서 노드 이동성을 고려한 견고한 경로 관리 기법)

  • Kim, Kwan-Woong;Bae, Sung-Hwan;Kim, Dae-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4A
    • /
    • pp.309-315
    • /
    • 2009
  • Wireless Ad-hoc networks are dynamic networks that consist of mobile nodes. Nodes in Ad-hoc networks are usually laptops, PDAs or mobile phones. These devices feature Bluetooth and/or IEEE 802.11 (WiFi) network interfaces and communicate in a decentralized manner. Due to characteristics of Ad-hoc networks, Mobility is a key feature of routing protocol design. In this paper, we present an enhanced routing maintenance scheme that cope with topology changes pre-actively. The key feature of the proposed scheme is to switch next-hop node to alternative neighbor node before link breakage for preventing route failure. From extensive experiments by using NS2, the performance of the proposed scheme has been improved by comparison to AODV protocol.

Design of 234.7 MHz Mixed Mode Frequency Multiplication & Distribution ASIC for ATM Switching System (ATM 교환기용 234.7 MHz 혼합형 주파수 체배분배 ASIC의 설계)

  • 채상훈;정희범
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1597-1602
    • /
    • 1999
  • An analog / digital mixed mode frequency multiplication and distribution ASIC for switch link or network synchronization of ATM switching system for B-ISDN has designed. This ASIC generates 234-7 MHz system clock and 77.76 MHz, 19.44 MHz user clocks using 46.94 MHz external clock. It also includes digital circuits for checking and selecting between the two external clocks. For effective ASIC design, full custom technique is used in analog PLL circuit and standard cell based technique is used in digital circuit. Resistors and capacitors are specially designed so the chip can be implemented in 0.8$\mu\textrm{m}$ digital CMOS technology.

  • PDF

A Study on the High-Efficiency. High-Power-Factor AC/DC Boost Converter Using Energy Recovery (에너지 회생 스너버를 적용한 고효률, 고역률 AC/DC Boost 컨버터에 관한 연구)

  • Ryu, Chang-Gyu;Kim, Yong;Bae, Jin-Yong;Baek, Soo-Hyun;Choi, Geun-Soo;Gye, Sang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.160-163
    • /
    • 2004
  • A passive lossless turn-on/turn-off snubber network is proposed for the boost PWM converter. Previous AC/DC PFC Boost Converter perceives feed forward signal of output for average current-mode control. Previous Boost Convertor, the Quantity of input current will be decreased by the decrease of output current in light load, and also Power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC, low line current harmonic distortions and tight output voltage regulations using energy recovery circuit. All of the semiconductor devices in the converter are turned on under exact or near zero voltage switching(ZVS). No additional voltage and current stresses on the main switch and main diode occur. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

Design of InfiniBand RDMA-based Network Structure of Apache Storm (InfiniBand RDMA 기반 Apache Storm의 네트워크 구조 설계)

  • Yang, Seokwoo;Son, Siwoon;Choi, Seong-Yun;Choi, Mi-Jung;Moon, Yang-Sae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.679-681
    • /
    • 2017
  • Apache Storm은 대용량 데이터 스트림을 처리하기 위한 실시간 분산 병렬 처리 프레임워크이며, 이를 사용해 다수의 프로세스 및 스레드를 동시에 동작시킬 수 있다. 하지만, 이러한 멀티 프로세스 및 스레드 환경을 제공하는 Storm은 많은 네트워크 시스템 호출을 수행하고, 이는 잦은 문맥 전환(context switch), 운영체제로의 버퍼 복사, 운영체제 내의 버퍼 복사 등으로 인해 CPU 과부하 문제를 발생시킬 수 있다. 이러한 문제는 고성능 네트워크 장비인 InfiniBand의 IPoIB(IP over InfiniBand) 통신을 사용할 때, InfiniBand가 지원하는 대역폭(bandwidth) 대비 저용량 데이터의 송수신으로 인해 더 잦은 문맥 전환과 버퍼 복사가 발생하여 CPU 과부하 문제가 더욱 심각해진다. 따라서, 본 논문에서는 InfiniBand의 RDMA(Remote Direct Memory Access)를 Storm에 적용하는 설계안을 제시함으로써 CPU 과부하 문제를 해결한다.

Development of the Base Station Controller and Manager in the CDMA Mobile System

  • Ahn, Jee-Hwan;Shin, Dong-Jin;Cho, Cheol-Hye
    • ETRI Journal
    • /
    • v.19 no.3
    • /
    • pp.141-168
    • /
    • 1997
  • The base station (BS) in the CDMA Mobile System (CMS) connects calls through the radio interface and is designed to provide mobile subscribers with high quality service in spite of mobile subscribers motions. The BS consists of multiple base station transceiver subsystems (BTSs), a base station controller (BSC) and a base station manager (BSM). This paper is concerned with the BSC and the BSM. The BSC is located between the BTSs and the mobile switching center (MSC) connected with the public network, and to mobile subscribers via the BTSs. The BSM provides operator-interfaces per the BS and takes responsibility of operation and maintenance (OAM) of the BS. Design of the BSC is based on two module types: functional module and unit module. The functional module is used to support new services easily and the unit module to increase the system capacity economically. Both modular types are easily achieved by inserting the corresponding modules to the system. Particularly, in order to efficiently support the soft handover which is one of CDMA superior advantages, the BSC adopts a large high-speed Packet switch connecting up to 512 BTSs, and thus mobile subscribers can be provided with soft handover in high probability. The BSM is based on a commercial workstation to support OAM functions efficiently and guarantee high reliability of the functions. The BSM uses graphical user interface (GUI) for efficient OAM functions of the BS.

  • PDF

The Development of Multi-Fault Restoration Algorithm for Distribution Network (배전계통 광역 정전복구 알고리즘 개발)

  • Jung, Jin-Soo;Lee, Seung-Jae;Jung, Jong-Wook;Lim, Young-Bae;Bae, Seok-Myung;Yi, Geon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.69-77
    • /
    • 2006
  • This paper presents the service restoration in electric power distribution systems. The aim of the service restoration is to control an emergency taken place in distribution systems and to restore out-of service areas as soon as possible when a fault occurs in distribution systems. For this reason, new service restoration strategies in multi-outage area are suggested in this paper. The suggested algorithm consist of two schemes. One is an individual restoration scheme, the other is an integrated restoration scheme. The former determines a restoration order of outage areas based on a restoration index. Unless the former scheme can generate a feasible restoration plan, the latter one will try to find out a new configuration without an overloaded section through tie exchange method.

Analysis of the Fixed Frequency LCL-type Converter at Continuous Current Mode Including Parasitic Losses (연속전류모드에서 기생손실들을 고려한 고정주파수 LCL형 컨버터 해석)

  • Park, Sangeun;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.785-793
    • /
    • 2016
  • This paper analyzes an LCL-type isolated dc-dc converter operating for constant output voltage in the continuous conduction mode(CCM) with resistances of parasitic losses-static drain-source on resistance of power switch, ESR of resonant network(L-C-L)-using a high loaded quality factor Q assumptions and fourier series techniques. Simple analytical expressions for performance characteristics are derived under steady-state conditions for designing and understanding the behavior of the proposed converter. The voltage-driven rectifier is analyzed, taking into account the diode threshold voltage and the diode forward resistance. Experimental results measured for a proposed converter at low input voltage and various load resistances show agreement to the theoretical performance predicted by the analysis within maximum 4% error. Especially in the case of low output voltages and large loads, It is been observed that introduction of both rectifier and the parasitic components of converter had considerable effect on the performance.

Design of Switchable and Reconfigurable Semi-lumped Wideband Bandpass Filter

  • Xiong, Yang;Wang, LiTian;Zhang, Wei;Pang, DouDou;Zhang, Fan;He, Ming
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.756-763
    • /
    • 2017
  • A switchable single-wideband (SWB)-to-dual-wideband (DWB) bandpass filter (BPF), which is realized by using lumped switches, is presented in this paper. By alternating the operation modes-ON and OFF-in which the ON mode is achieved by placing the capacitors at the switching spots and the OFF mode is achieved by replacing the capacitors with inductors, DWB-to-SWB BPF can be achieved on the same device. In addition, by changing the capacitor values, the center frequency (CF) of the lower passband of DWB BPF can be easily tuned from 1.69 GHz to 2.22 GHz, while the higher passband stays almost unchanged. As an example, an SWB-to-DWB BPF is designed, fabricated, and measured. This BPF exhibits good performance including wideband, high isolation, compact size, and ability to switch.

Implementation of ATM Switch Interface Function for Radio Network Controller in IMT-2000 Asynchronous System (IMT-2000 비동기 시스템에서 무선망 제어국의 ATM 스위치 정합 기능 구현)

  • JANG, J.D.;JANG, M.S.
    • Electronics and Telecommunications Trends
    • /
    • v.16 no.6 s.72
    • /
    • pp.1-8
    • /
    • 2001
  • IMT-2000 비동기 시스템은 단말기, 기지국과 무선망 제어국으로 구성되는 무선 접속망 그리고 핵심망 등으로 구성된다. 특히 IMT-2000 비동기 시스템의 무선망 제어국은 기지국과 접속 기능을 가지는 기지국 정합용 무선 접속 서브 시스템, 무선 트래픽 채널의 소프트 핸드오프 처리 기능을 가지는 트래픽 처리용 무선 접속 서브 시스템, 무선망 제어국을 제어하는 무선망 제어국 제어용 서브 시스템, 그리고 회선 및 패킷 교환망을 수용하는 핵심망 및 타 무선망 제어국과의 접속 기능을 수행하는 망 정합용 무선 접속 서브 시스템으로 구성된다. 본 논문에서는 다양한 서비스 품질 파라미터를 갖는 서비스를 지원하기 위한 전달 기능으로서 ATM을 기반으로 하는 ATM 스위치 망을 IMT-2000 비동기 시스템의 무선망 제어국에 적용하여 무선망 제어국의 각 서브 시스템 간 접속시켜 통신 경로 제공 기능을 수행하도록 하였다. 따라서 기지국과 핵심망 사이를 상호 연결하여 음성 및 데이터의 트래픽 정보와 제어 정보를 전달하는 기능을 수한다. 이와 같이 IMT-2000 비동기 시스템에서는 무선망 제어국 내의 서브 시스템과의 접속은 ATM 스위치를 통하여 사용자의 요구에 따라 가변적으로 필요한 대역폭을 제공함으로써 사용자의 요구에 부합되는 통신 수단을 제공할 뿐만 아니라 기존의 IMT-2000 이전 시스템의 서비스 보다는 훨씬 향상된 품질의 패킷 데이터와 멀티미디어 서비스를 포함하는 오디오, 비디오, 그리고 데이터 서비스를 제공할 수 있다.

Alum Directly Modulates Murine B Lymphocytes to Produce IgG1 Isotype

  • Jin, Bo-Ra;Kim, Sun-Jin;Lee, Jeong-Min;Kang, Seong-Ho;Han, Hye-Ju;Jang, Young-Saeng;Seo, Goo-Young;Kim, Pyeung-Hyeun
    • IMMUNE NETWORK
    • /
    • v.13 no.1
    • /
    • pp.10-15
    • /
    • 2013
  • Aluminum hydroxide (alum) is the most widely used adjuvant in human vaccines. Nevertheless, it is virtually unknown whether alum acts on B cells. In the present study, we explored the direct effect of alum on Ig expression by murine B cells in vitro. LPS-activated mouse spleen B cells were cultured with alum, and the level of isotype-specific Ig secretion, IgG1 secreting cell numbers, and Ig germ-line transcripts (GLT) were measured using ELISA, ELISPOT, and RT-PCR, respectively. Alum consistently enhanced total IgG1 production, numbers of IgG1 secreting cells, and $GLT{\gamma}1$ expression. These results demonstrate that alum can directly cause IgG1 isotype switching leading to IgG1 production.