• Title/Summary/Keyword: Neck sensor

Search Result 55, Processing Time 0.037 seconds

Implementation of the automatic pulse-power diagnostic system and the discrimination algorithm of four constitutions (사상 체질 판별 알고리즘과 자동 맥진 시스템의 구현)

  • 박승창;김대진
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.53-60
    • /
    • 2004
  • This paper is the study for the automatic pulse-power diagnostic system to discriminate the four constitutions with the piezo-sensor module and digital signal processing hardware attached on the patient arm-neck and the statistical decision software instead of the fingers and intelligence of a traditional korean doctor. This system can be used as a important medical equipment because this automatically diagnostic system has shown the excellent performance of the 65∼76% correctness against the 50∼66% correctness which the general korean doctors with knowledge and experiences have shown. Additionally, this paper has discussed the excellent characteristics of the automatic discrimination algorithm of the four constitutions.

Vocal Exercise System Using Electroglottography (성문전도를 이용한 발성훈련 시스템)

  • Lee, Je-Hyun;Kim, Ji-Hye;Kang, Gu-Tae;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.156-161
    • /
    • 2013
  • This study was aimed to implement the electroglottography (EGG) system for analyzing fundamental frequency of the phonation. EGG was recorded from the conductance between ring electrodes attached to the neck skin area near thyroid cartilage with high frequency carrier electric signals during vocalization, and voice signal was recorded with microphone simultaneously. EGG and voice signals were transmitted to the audio port in PC and recorded with stereo sound recording program. From the digitized data, several parameters such as pitch, jitter, shimmer, CQ and SQ were analyzed from the vowel sounds. For the voice training, sound fundamental frequency was displayed during the vocalization and singing a song using pitches analyzed from the EGG. The system implemented in this study could be used for vocal exercise.

A Study on the Assistive System for Body Correction (신체 교정을 위한 보조 시스템에 관한 연구)

  • Kim, Ho-Joon;Chung, Jae-Pil
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.231-235
    • /
    • 2011
  • In these day, the number of people who have an abnormal posture caused by bad habit are increasing. Therefore, people suffer various disease and symptoms. For correcting the posture to cure, we need continuous monitor, expenditure of time and money. In this study, we develop a posture correcting aid system in other to monitor a posture continuously and leads to pose correctly and records postural variation which are attached to the neck and the waist. The devised system showed good potential for the correct posture guide and a cure of postural defect.

A Development of Turtle Neck Posture Notification Application using Gyro Sensor (자이로센서를 활용한 거북목 자세 알림 애플리케이션 개발)

  • Hong, Ju-Yeon;Lee, Min-Ji;Yang, Hyeon-Jin;Choi, Bo-Sun;Kim, Jin-Man;Lee, Eui Chul
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.860-862
    • /
    • 2018
  • 오늘날, 현대인들의 생활 속에서 스마트폰을 빼놓을 수 없을 만큼 스마트폰을 장시간 이용하는 사람들이 많다. 스마트폰 이용시간이 늘어날수록 목을 숙인 자세를 유지하게 되며, 이는 VDT 증후군 중 거북목증후군을 발생시킬 가능성이 높다. 본 논문에서는 사용자의 목 각도를 유추해 거북목 자세가 일정시간 유지될 때 알림기능을 제공하는 애플리케이션을 개발하였다. 애플리케이션을 통해 스마트폰 사용자들이 자신의 자세를 인지하고 올바른 자세로 교정할 수 있도록 유도하였다. 본 애플리케이션은 스마트폰의 기울기에 따라 사용자의 목각도를 추측하기 때문에, 스마트폰의 기울기와 목각도간의 상관성 분석 실험을 수행하여 애플리케이션의 유효성을 입증하였다.

Intelligent Robust Base-Station Research in Harsh Outdoor Wilderness Environments for Wildsense

  • Ahn, Junho;Mysore, Akshay;Zybko, Kati;Krumm, Caroline;Lee, Dohyeon;Kim, Dahyeon;Han, Richard;Mishra, Shivakant;Hobbs, Thompson
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.3
    • /
    • pp.814-836
    • /
    • 2021
  • Wildlife ecologists and biologists recapture deer to collect tracking data from deer collars or wait for a drop-off of a deer collar construction that is automatically detached and disconnected. The research teams need to manage a base camp with medical trailers, helicopters, and airplanes to capture deer or wait for several months until the deer collar drops off of the deer's neck. We propose an intelligent robust base-station research with a low-cost and time saving method to obtain recording sensor data from their collars to a listener node, and readings are obtained without opening the weatherproof deer collar. We successfully designed the and implemented a robust base station system for automatically collecting data of the collars and listener motes in harsh wilderness environments. Intelligent solutions were also analyzed for improved data collections and pattern predictions with drone-based detection and tracking algorithms.

Analysis and Improvement for Method of Boiling Point Measurement described in Middle School Science Textbooks (중학교 과학 교과서에 기술된 끓는점 측정 방법 분석 및 개선점 제안)

  • Noh, Eul;Jang, Nak Han
    • Journal of Science Education
    • /
    • v.39 no.3
    • /
    • pp.446-456
    • /
    • 2015
  • We have analyzed affecting factors of boiling point measurement and proposed to improve these after identifying errors of boiling point experiment in 7th grade science textbooks of 2009 revised curriculum. In the result of analyzing affecting factor of boiling point measurement for nine kinds of science textbooks, we have identified six affecting factors like as types of thermometer, heating instrument, sealing or not of stopper, position of thermometer, shape of container, and volume ratio of material and container. When performing experiment of boiling point measurement, we identified the best results when heating with a hot plate, positioning thermo sensor of MBL near neck branch after filling and sopping 10% volumes of material in round bottom flask. Based on this result, we have compared nine kinds of 7th grade science textbooks and found many errors that must be corrected in most of textbooks. Therefore it should be improved the experiment of science textbooks to enhance the understanding of students and to prevent from misconceptions for boiling point measurement.

  • PDF

A review on measuring cervical range of motion using an inertial measurement unit (관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰)

  • Yim, Juhyuk;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

Cervical stabilization exercise using the Sling system (슬링(Sling) 시스템을 이용한 경부 안정화 운동)

  • Kwon, Jae-Hoak;Cho, Mi-Ju;Park, Min-Chull;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.8 no.2
    • /
    • pp.57-71
    • /
    • 2002
  • Cervical pain is a rapid increase that is owing to a flexion-extension whiplash injury, unappropriated posture, chronical repetition injury from abdominal position of head and neck, excessive repeating work, chronical deficiency of excercise. Because of that is bring about muscle unbalance, tightness of cervical extensor muscle, weakness of cervical deep flexor muscles, instability of cervical region and reduction of proprioceptive sensor. Recent the role of muscle is more emphasized for preservation of sine stabilization. And cognition of integrated muscular system, importance for the operation and relation is increased to maintain stability of the motor system and pertinent function. Therefore we are going to introduce the sling exercise and stabilization exercise method for advanced efficient of cervical and upper limb and for the muscle strengthening to importance cervical stabilization through neurological program as control the reaction of cervical stabilization. Sling exercise therapy(SET) concept consists of a system of diagnosis and treatment. The system of diagnosis involves testing the muscle's tolerance through progressive loading in open and close kinetic chains. The SET system contains elements such as relaxation, increasing the range of movement, traction, training the stabilizing musculature, sensory-motor exercises, training in open and close kinetic chains, dynamic training of the mobilizing musculature, cardiovascular exercise, group exercise, personal exercise at home Sensory-motor training is an essential element of the SET concept. The emphasis is on closed kinetic chain exercise on an unstable surface, there by achieving optimum stimulation of the sensory-motor apparatus.

  • PDF

Cow Residual Feed Intake(RFI) monitoring and metabolic abnormality prediction system using wearable device for Milk cow and Beef

  • Chang, Jin-Wook;Kwak, Ho-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.10
    • /
    • pp.139-145
    • /
    • 2021
  • In this paper, by using the cattle feed intake, rumination, and in heat monitoring technology, RFI (Residual Feed Intake) monitoring and wearable devices and PCs for predicting abnormalities in budding target web and smart A monitoring system using a phone application was designed and implemented. With the development of this system, the farmer is expected to increase economic efficiency. By analyzing the feed intake, it is possible to identify the difference between the recommended feed amount based on the cow's weight and the feed amount consumed by the cow, and it is expected that early detection of metabolic disorders (abnormality of metabolism) is possible. Farmers using the results of this thesis can distinguish the cows with the most efficient performance, and the 6-axis motion sensor signals input from the wearable device attached to the cow's skin (neck) and the microphone attached to the wearable device. It is possible to measure the cow's rumination and feed intake through the sound of the cow's throat. In the future, improvements will be made to measure additional vital signs such as heart rate and respiration.

Study On The Development of Mobile Shampoo Device Using Ozone Water For Good hair condition (모발에 좋은 오존수를 이용한 이동식 샴푸 장치 개발에 관한 연구)

  • Kim, Duck-Sool
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.394-399
    • /
    • 2017
  • The goal of this study is to suggest the technology and the way of developing ergonomic shampoo device, which is able to adjust the height and to be devided, and it uses ozone water. As a result of developing the device, it can complete better the effect of preventing water splash than existing devices by making neck holding part higher. And it is also made with ergonomic design, therefore, the head of shampoo candidate can be drawn into it more easily. By adjusting water temperature($38^{\circ}C$) to candidate's taste through water heater attached to water bucket, when a candidate is being shampooed, it can help keep warm shampooing without delaying. We could know the process through temperature sensor. And we could also know the utility of its own sterilization(1PPM) and purification. Finally, ozone water was measured for 20 minutes and the ozone concentration was measured to be less than 1 PPM to ensure stability. All parts of the mobile shampoo stand together with the hot water device and the ozonated water conversion device were designed so as not to be inconvenient for the user to use.