• 제목/요약/키워드: Near Infrared(NIR) Spectroscopy

검색결과 373건 처리시간 0.027초

Prediction of Heavy Metal Content in Compost Using Near-infrared Reflectance Spectroscopy

  • Ko, H.J.;Choi, H.L.;Park, H.S.;Lee, H.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권12호
    • /
    • pp.1736-1740
    • /
    • 2004
  • Since the application of relatively high levels of heavy metals in the compost poses a potential hazard to plants and animals, the content of heavy metals in the compost with animal manure is important to know if it is as a fertilizer. Measurement of heavy metals content in the compost by chemical methods usually requires numerous reagents, skilled labor and expensive analytical equipment. The objective of this study, therefore, was to explore the application of near-infrared reflectance spectroscopy (NIRS), a nondestructive, cost-effective and rapid method, for the prediction of heavy metals contents in compost. One hundred and seventy two diverse compost samples were collected from forty-seven compost facilities located along the Han river in Korea, and were analyzed for Cr, As, Cd, Cu, Zn and Pb levels using inductively coupled plasma spectrometry. The samples were scanned using a Foss NIRSystem Model 6500 scanning monochromator from 400 to 2,500 nm at 2 nm intervals. The modified partial least squares (MPLS), the partial least squares (PLS) and the principal component regression (PCR) analysis were applied to develop the most reliable calibration model, between the NIR spectral data and the sample sets for calibration. The best fit calibration model for measurement of heavy metals content in compost, MPLS, was used to validate calibration equations with a similar sample set (n=30). Coefficient of simple correlation (r) and standard error of prediction (SEP) were Cr (0.82, 3.13 ppm), As (0.71, 3.74 ppm), Cd (0.76, 0.26 ppm), Cu (0.88, 26.47 ppm), Zn (0.84, 52.84 ppm) and Pb (0.60, 2.85 ppm), respectively. This study showed that NIRS is a feasible analytical method for prediction of heavy metals contents in compost.

국내 원산지별 고춧가루의 매운맛 비파괴 측정기술 개발 (Development of non-destructive pungency measurement technique for red-pepper powder produced in different domestic origins)

  • 모창연;이강진;임종국;강석원;이현동;조병관
    • 농업과학연구
    • /
    • 제39권4호
    • /
    • pp.603-612
    • /
    • 2012
  • In this research, the feasibility of non-destructive measurement technique of pungency measurement was investigated for the red-pepper powders produced in different domestic areas in South Korea. The near-infrared absorption spectra in the range of 1100 nm~2300 nm was used to measure capsaicinoids content in red-pepper powders by using a NIR spectroscopy equipped with Acousto-optic tunable filters (AOTF). Fourth three different red-pepper powders from 14 different locations were collected and separated in three different particle size (below 0.425 mm, 0.425~0.71 mm, 0.71~1.4 mm) for the spectral measurements. The partial least square regression (PLSR) models to predict the capsaicinoids content depends on particle size were developed with the measured spectra. The determinant coefficients and standard errors of the developed models for the red-pepper powders of below 0.425 mm, 0.425~0.71 mm, and 0.71~1.4 mm were in the range of 0.859~0.887 and 12.90~12.99 mg/100 g, respectively. The PLS model with the pretreatment of Standard Normal Variate (SNV) for the red-pepper powders below 1.4 mm particle size showed the best performance with the determinant coefficient of 0.844 and the standard error of 14.63 mg/100 g.

SAVITZKY-GOLAY DERIVATIVES : A SYSTEMATIC APPROACH TO REMOVING VARIABILITY BEFORE APPLYING CHEMOMETRICS

  • Hopkins, David W.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1041-1041
    • /
    • 2001
  • Removal of variability in spectra data before the application of chemometric modeling will generally result in simpler (and presumably more robust) models. Particularly for sparsely sampled data, such as typically encountered in diode array instruments, the use of Savitzky-Golay (S-G) derivatives offers an effective method to remove effects of shifting baselines and sloping or curving apparent baselines often observed with scattering samples. The application of these convolution functions is equivalent to fitting a selected polynomial to a number of points in the spectrum, usually 5 to 25 points. The value of the polynomial evaluated at its mid-point, or its derivative, is taken as the (smoothed) spectrum or its derivative at the mid-point of the wavelength window. The process is continued for successive windows along the spectrum. The original paper, published in 1964 [1] presented these convolution functions as integers to be used as multipliers for the spectral values at equal intervals in the window, with a normalization integer to divide the sum of the products, to determine the result for each point. Steinier et al. [2] published corrections to errors in the original presentation [1], and a vector formulation for obtaining the coefficients. The actual selection of the degree of polynomial and number of points in the window determines whether closely situated bands and shoulders are resolved in the derivatives. Furthermore, the actual noise reduction in the derivatives may be estimated from the square root of the sums of the coefficients, divided by the NORM value. A simple technique to evaluate the actual convolution factors employed in the calculation by the software will be presented. It has been found that some software packages do not properly account for the sampling interval of the spectral data (Equation Ⅶ in [1]). While this is not a problem in the construction and implementation of chemometric models, it may be noticed in comparing models at differing spectral resolutions. Also, the effects on parameters of PLS models of choosing various polynomials and numbers of points in the window will be presented.

  • PDF

저온에서 형성된 니켈실리사이드의 적외선 흡수 특성 (IR Absorption Property in Nano-thick Nickel Silicides)

  • 한정조;송오성;최용윤
    • 한국재료학회지
    • /
    • 제19권4호
    • /
    • pp.179-185
    • /
    • 2009
  • We fabricated thermally evaporated 30 nm-Ni/(20 nm or 60 nm)a-Si:H/Si films to investigate the energy-saving property of silicides formed by rapid thermal annealing (RTA) at temperatures of $350^{\circ}C$, $450^{\circ}C$, $550^{\circ}C$, and $600^{\circ}C$ for 40 seconds. A transmission electron microscope (TEM) and a high resolution X-ray diffractometer (HRXRD) were used to determine the cross-sectional microstructure and phase changes. A UVVIS-NIR and FT-IR (Fourier transform infrared spectroscopy) were employed for near-IR and middle-IR absorbance. Through TEM and HRXRD analysis, for the nickel silicide formed at low temperatures below $450^{\circ}C$, we confirmed columnar-shaped structures with thicknesses of $20{\sim}30\;nm$ that had ${\delta}-Ni^2Si$ phases. Regarding the nickel silicide formed at high temperatures above $550^{\circ}C$, we confirmed that the nickel silicide had more than 50 nm-thick columnar-shaped structures with a $Ni_{31}Si_{12}$ phase. Through UV-VIS-NIR analysis, nickel silicide showed almost the same absorbance in the near IR region as well as ITO. However, in the middle IR region, the nickel silicides with low temperature showed similar absorbance to those from high temperature silicidation.

수염 자극 시 대뇌수염피질에서의 혈류변화에 따른 근적외선 신호와 전기신호의 동시측정 (Simultaneous measurements of NIR and electrical signals on rat brain during whisker stimulation)

  • 이승덕;권기운;고달권;호동수;김법민;이현주;랑이란;신형철
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 동계학술발표회 논문집
    • /
    • pp.455-456
    • /
    • 2008
  • 근적외선 분광법(Near-infrared spectroscopy, NIRS)은 대뇌피질에서의 혈류변화(oxy-, deoxyhemoglobin의 농도변화)를 비침습적으로 측정할 수 있는 방법이다. 본 논문에서는 향후 뇌-컴퓨터 접속기술(Brain computer interface)에 적용하기위한 초기 연구단계로, 쥐의 수염을 자극시 활성화되는 대뇌수염피질 영역에서의 혈류변화 및 전기신호를 동시에 측정하고 두 신호의 패턴을 분석한다.

  • PDF

컴퓨터 게임 중 fNIRS 기반 뇌 활성화 연구 (A Study on Brain Activation during playing a computer game using a fNIRS)

  • 강원석;;이승현;안진웅
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2009년도 추계학술발표대회
    • /
    • pp.407-408
    • /
    • 2009
  • fNIRS(functional Near Infrared Spectroscopy)는 비침습형 뇌기능 분석 시스템으로 뇌활성화 시 옥시 헤모글로빈(oxy-hemoglobin)과 디옥시헤모글로빈(deoxy-hemoglobin) 변화량을 측정할 수 있는 장치이다. 본 논문에서는 뇌기능 분석 장치인 fNIRS를 이용하여 피험자가 컴퓨터 게임 중에 어떤 뇌활성화 패턴을 보이는지를 실험하였다. 컴퓨터 게임 주의 및 집중 시 뇌의 전두엽(Frontal Lobe) 영역이 활성화 및 변화되는 것을 실험결과로 확인하였다. 그리고 게임 중 다른 사람이 피험자에게 개입을 하였을 때 전두엽의 활성화 영역이 다른 패턴을 보이는 것을 실험결과로 확인하였다.

근적외선분광(NIRS)을 이용한 참깨의 lignan 함량 비파괴 분석 방법 확립 (Establishment of a Nondestructive Analysis Method for Lignan Content in Sesame using Near Infrared Reflectance Spectroscopy)

  • 이정은;김성업;이명희;김정인;오은영;김상우;김민영;박재은;조광수;오기원
    • 한국작물학회지
    • /
    • 제67권1호
    • /
    • pp.61-66
    • /
    • 2022
  • 본 연구는 참깨에 함유된 세사민 및 세사몰린의 함량을 비파괴적으로 신속하게 평가하기 위하여 NIRS 분석을 이용해 검량식을 작성하고 검량식의 적용가능성을 검증하였다. 검량식 작성에 사용된 482점 참깨의 HPLC 분석 결과를 NIRS 스펙트럼에 적용시킨 후 검량식을 작성하였다. 세사민 및 세사몰린의 R2 값은 각각 0.936, 0.875로 조사되었으며 이를 cross validation 한 결과에서도 각각 0.899, 0.781로 조사되어 리그난 함량 분석에 적용 가능할 것으로 판단되었다. 작성된 검량식의 적용가능성을 확인하기 위해 2020년에 생산된 참깨 유전자원 90종의 종자를 NIRS를 통해 분석한 결과 세사민 및 세사몰린의 R2값이 각각 0.653, 0.596으로 크게 낮아졌으나 리그난 함량이 높은 상위 30%의 자원을 선발하는데 무리가 없었다. 따라서 본 연구에서 작성된 NIRS 검량식은 육종 초기에 고리그난 함량을 선발하는데 적용 가능할 것으로 판단된다.

가시광선-근적외선 반사스펙트럼을 이용한 쇠고기의 신선도 평가 (Evaluation of Beef Freshness Using Visible-near Infrared Reflectance Spectra)

  • 최창현;김종훈;김용주
    • 한국축산식품학회지
    • /
    • 제31권1호
    • /
    • pp.115-121
    • /
    • 2011
  • 본 연구에서는 유통현장에서 실시간으로 쇠고기 신선도를 측정하기 위해 가시광선-근적외선 반사 스펙트럼을 이용하여 쇠고기 신선도에 영향을 미치는 인자와 설정된 저장기간에 대하여 예측 모델을 개발하고 검증하였다. 쇠고기 시료는 총 216개를 사용하였으며 0-14일의 기간 동안 2일 간격으로 가시광선-근적외선 반사 스펙트럼을 측정한 후, 쇠고기의 신선도에 영향을 미치는 인자인 총균수, pH, VBN, TMA, TBA값을 공인된 방법을 이용하여 측정하였다. 예측모델은 다중회귀분석 방법과 최적 변수 선택이 가능한 stepwise 방법을 이용하여 개발하였으며, 예측모델의 선정은 결정계수, 오차, RPD를 이용하였다. 예측모델의 검증은 미지의 시료를 이용하였으며 그 결과 결정계수, 오차, RPD는 총균수에서 각각 0.74, 0.64, 2.75 Log CFU/$cm^2$, VBN은 각각 0.73, 1.45, 2.00 mg%, TMA는 각각 0.70, 0.19, 2.58 mg%, TBA값은 각각 0.73, 0.13, 2.77 mg MA/kg로 비교적 안정된 예측성능을 보여 주었다. 저장기간에 따른 예측모델의 검증결과는 결정계수, 오차, RPD가 각각 0.77, 1.94일, 2.53으로 실험 시 저장기간이 2일 간격인 점을 고려할 때, 비교적 높은 정밀도를 보이고 있음을 알 수 있다. pH의 예측성능은 결정계수, 오차, RPD가 각각 0.43, 0.10, 1.10로 다른 신선도 인자에 비해 낮은 결과를 보여 주었다. 본 연구에서는 가시광선-근적외선 분광분석법을 이용하여 쇠고기 신선도의 비파괴 평가에 대한 가능성을 제시하였으나 유통현장에서 적용을 위해서는 보다 많은 시료의 확보를 통한 예측모델의 신뢰성 향상과 stepwise방법으로 선정된 파장 영역을 기본으로 하는 부분최소자승법, 인공지능 등의 다양한 알고리즘의 적용을 통한 성능개선이 필요할 것으로 판단된다.

CuInS2 나노 반도체 합성 및 표면 개질을 통한 광학적 효율 분석 연구 (Synthesis and Characterization of CuInS2 Semiconductor Nanoparticles and Evolution of Optical Properties via Surface Modification)

  • 양희승;김유진
    • 한국분말재료학회지
    • /
    • 제19권3호
    • /
    • pp.177-181
    • /
    • 2012
  • Copper composite materials have attracted wide attention for energy applications. Especially $CuInS_2$ has a desirable direct band gap of 1.5 eV, which is well matched with the solar spectrum. $CuInS_2$ nanoparticles could make it possible to develop color-tunable $CuInS_2$ nanoparticle emitter in the near-infrared region (NIR) for energy application and bio imaging sensors. In this paper, $CuInS_2$ nanoparticles were successfully synthesized by thermo-decomposition methods. Surface modification of $CuInS_2$ nanoparticles were carried out with various semiconductor materials (CdS, ZnS) for enhanced optical properties. Surface modification and silica coating of hydrophobic nanoparticles could be dispersed in polar solvent for potential applications. Their optical properties were characterized by UV-vis spectroscopy and photoluminescence spectroscopy (PL). The structures of silica coated $CuInS_2$ were observed by transmission electron microscopy (TEM).