• 제목/요약/키워드: Near Field Test

검색결과 352건 처리시간 0.025초

옥외 전기시설물 침수시 누설전류에 의한 인체영향 (Human Hazard by Outdoor Electrical Facilities in Submerged Area)

  • 하태현;이현구;배정효;김대경
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.

철도변 환경소음저감:세부실천계획과 방음대책 (Community Noise: Guidelines and Policy)

  • 김정태;김정수;김홍찬;손정곤;강대준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.91-98
    • /
    • 2007
  • Community noise has been serious social issues in Korea. This paper reviews current statistics and status on railway noise, with practical engineering tools in order to reduce the noise level from railway traffic noise sources. At the beginning, guidelines of the current environmental policy are discussed, with the new policy on railway noise to be enforced beginning in 2007 with 5 year schedule. Then, a noise reducer is proposed as a tool to reduce noise levels protecting people living near at the railway. Details on the acoustic effect in field test are discussed with the result of implementation in the street. We propose noise reducers as an effective and practical tool for the people who are exposed to rail traffic noise in cities.

  • PDF

Testing Gravity with Cosmic Shear Data from the Deep Lens Survey

  • Sabiu, Cristiano G.;Yoon, Mijin;Jee, M. James
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.62.2-62.2
    • /
    • 2018
  • From the gaussian, near scale-invariant density perturbations observed in the CMB to the late time clustering of galaxies, CDM provides a minimal theoretical explanation for a variety of cosmological data. However accepting this explanation, requires that we include within our cosmic ontology a vacuum energy that is ~122 orders of magnitude lower than QM predictions, or alternatively a new scalar field (dark energy) that has negative pressure. Alternatively, modifications to Einstein's General Relativity have been proposed as a model for cosmic acceleration. Recently there have been many works attempting to test for modified gravity using the large scale clustering of galaxies, ISW, cluster abundance, RSD, 21cm observations, and weak lensing. In this work, we compare various modified gravity models using cosmic shear data from the Deep Lens Survey as well as data from CMB, SNe Ia, and BAO. We use the Bayesian Evidence to quantify the comparison robustly, which naturally penalizes complex models with weak data support. In this poster we present our methodology and preliminary constraints on f(R) gravity.

  • PDF

Tidal Current Power Generation by a Darrieus Type Water Turbine at the Side of a Bridge Pier

  • Kyozuka, Yusaku;Wakahama, Hisanori
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.99-104
    • /
    • 2006
  • There are several advantages to make use of a bridge pier for the tidal power generation. Current velocity increases near the pier, therefore the tidal power generation becomes more efficient because the power is proportional to the cubic of the current velocity. The pier is convenient for access and maintenance of the hydraulic turbine and the power unit. The project is now underway at the Ikitsuki Bridge in Tatsuno-Seto Strait of Nasasaki Prefecture, where the tidal current was measured by the bottom mount ADCP for almost one year. Model experiments for a Darrieus water turbine with two and three straight blades were carried out in the circulating water channel, in which the power coefficients of the turbine were obtained as a function of blade section and the attaching angle of a blade to the rotor. Those experimental results are discussed to obtain an optimum Darrieus turbine for tidal power generation.

  • PDF

전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성 (The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway)

  • 김재문;안승호;김양수;김철수
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

다단 루츠 드라이 진공펌프 기술 개발 (Development of Multistage Roots Dry Vacuum Pump Technology)

  • 류재경
    • 진공이야기
    • /
    • 제2권4호
    • /
    • pp.39-46
    • /
    • 2015
  • After stepping into a new field of vacuum 30 years ago, our company has grown up steadily as a specialized vacuum industry, and now we can provide vacuum devices covering most of the pressure range. We are planning to put out high level dry pump like a multistage Roots pump on the market in the near future. Procedures of technology development for designing, fabricating, and testing the multistage Roots pump of 600 L/min class will be briefly reported. Core items of the technical development on the multistage Roots pump are as follows; elaborated profile design of 3-lobe rotors using an involute curve, optimization of rotor dimensions, especially for clearances and rotor width, considering the pumping speed, compression ratio and heat load, and establishment of a standardized test system. At present, the multistage Roots pump is about to come into commercialization.

상수사용량(上水使用量)의 확률분포(確率分布) 특성(特性) (Probability Distribution Characteristics of water Supply Demand)

  • 목동우;현인환
    • 상하수도학회지
    • /
    • 제8권2호
    • /
    • pp.35-42
    • /
    • 1994
  • This study is to analyse probability distribution characteristics of water supply demand. Two cities located near Seoul were selected as study areas. In this study, two probalility distribution types were tested using the K-S(Kolmogorov-Smirnov) method. The K-S method was used to prove the goodness of the selected distribution type. And also, the goodness of maximum day demand to average day demand ratio which was obtained by field data was tested. Conclusions are as follows. 1.Bothl normal distribution type and lognormal distribution type are appropriate as the probalility distribution type for the water supply demand. 2. The probability distribution characteristics can be used to test the goodness of the maximum day to average day demand ratio.

  • PDF

토양의 지중방전에 따른 소형 침봉전극의 과도접지임피던스 (Transient Ground Impedance of Small-sized Needle-rod Electrodes due to Underground Soil Discharge)

  • 이태형;조성철;엄주홍;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.211-215
    • /
    • 2008
  • This paper deals with the transient ground impedance of small-sized needle-rod installed in a test field, Impulse voltage generator was used to inject lightning impulse on a ground electrode and modified fall-of potential method was proposed to measure the high ground potential rise. Transient ground impedance was analysed with impedance curve and I-V curve as respects the resistivity of soil. Soil ionization near the ground electrode is activated in high resistivity soil and have an effect on the reduction of transient ground impedance significantly.

  • PDF

크레인의 고압 전선로 접근 경보장치 (A Power Line Proximity Detecter for Mobile Crane)

  • 최삼진;김현식;이종호;김일환;박찬원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2374-2376
    • /
    • 2001
  • In this paper we have developed a Power Line Proximity Detecting device for Mobile Crane by using a Derivation Electric-Potential Detection method. A mobile crane worker can be easily exposed to a dangerous electrical shock and the electrocution while they are working at near the high-voltage electrical lines. The derivation electric-potential of the power lines have been simulated in our experiment, Also, microprocessor-based detecting device and transmitter/receiver modules are introduced to show a solution for the dangerous mobile crane working environment. As a result, It has been shown a good functional field test.

  • PDF

폴리스타이렌/폴리아닐린 전도성 블렌드의 전하분포 특성 (Charge Distribution Characteristics of Polystyrene/Polyaniline Conducting Blends)

  • 김원중;고정우;박창모;서광석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1457-1459
    • /
    • 2003
  • Space charge distributions and behaviors of polystyrene/polyaniline conducting blends were investigated using a pulsed electroacoustic(PEA) method. It was found that positive charges were accumulated near the cathode with increasing polyaniline content in polystyrene/polyaniline when electric field was applied. Breakdown phenomena was investigated by breakdown test and it was observed that dielectric strength was diminished as polyaniline content was increased. By Scanning Electron Microscopy, corss-sectional views of polystyrene/polyaniline conducting blends were observed that the particles of polyaniline were well distributed in polystyrene.

  • PDF