• Title/Summary/Keyword: Natural Convection Cooling

검색결과 145건 처리시간 0.03초

자연대류를 고려한 전류도입선의 최적설계 (Optimal design of Current lead considering Natural convection)

  • 손봉준;설승윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.103-108
    • /
    • 2003
  • In this paper, the current lead for superconducting device is studied by numerical method. The current lead is cooled by surrounded $N_{2}$ gas by natural convection. The heat conduction equation for current lead and boundary layer equation for $N_{2}$ gas must be solved simultaneously. The boundary layer equation for $N_{2}$ gas is highly nonlinear for varied temperature of current lead. So the linearization method is adopted for simplicity. Numerical results using natural convection cooling are compared with the conventional cooling methods such as conduction cooling and vapor cooling methods. The main difference of natural convection cooing is the non-zero temperature gradient at the top of current lead for the minimum heat dissipation into superconducting devices. For the optimized conduction-cooling and vapor-cooling current leads, the temperature gradient at the top of current lead is zero. Also, the heat flow at the cold end is much smaller than conduction cooling case.

  • PDF

자연대류와 강제대류에서 펠티에 소자를 이용한 내부터널 구조를 가지는 히트싱크에 관한 연구 (A Study on the Heat Sink with internal structure using Peltier Module In the Natural and Forced Convection)

  • 이민;김태완
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4072-4080
    • /
    • 2014
  • 펠티에 소자는 전자부품이나 장비에서 발생하는 열을 냉각하기 위한 방법으로 많이 사용되고, 히트싱크는 이러한 열을 외부로 방출하기 위한 방법으로 많이 사용되고 있다. 본 연구에서는 내부터널의 형상을 가지는 히트싱크에 대한 냉각 및 히팅성능을 자연대류와 강제대류 상태에서 열전달 특성에 대하여 고찰하였다. 또한, 시간에 따른 히트싱크의 열전달 특성 및 온도분포의 변화에 따른 실험을 수행하였고, 자연대류와 강제대류에 따른 히트싱크의 열전달 특성, 온도분포의 변화를 실험을 통해 비교 연구 하였다. 냉각 실험에서 A형상 및 B형상 냉각 핀 히트싱크는 자연대류보다는 강제대류에서 온도가 더 감소하는 것을 알 수가 있었고, 강제대류와 자연대류에서 A, B형상 모두 $-15^{\circ}C$까지 떨어지는 것을 알 수 있었다. 전압이 증가 할수록 강제대류와 자연대류 상태에서 A, B형상 냉각 핀 히트싱크 모두 온도가 감소하였다. 히팅실험에서 A형상 및 B형상 냉각 핀 히트싱크는 자연대류보다는 강제대류에서 온도가 더 증가하는 것을 알 수가 있었고, 강제대류와 자연대류에서 전압이 13V일 때, A형상 냉각 핀 히트싱크는 전압이 $150^{\circ}C$, 강제대류에서 B형상 냉각 핀 히트싱크는 $145^{\circ}C$까지 증가하였다. 전압이 증가할수록 강제대류와 자연대류 상태에서 A, B형상 냉각 핀 히트싱크 모두 온도가 증가하였다.

HTS변압기에서 액체질소 표면 상부의 열전달 해석 (Heat Transfer Analysis above L$N_2$ Surface in HTS Transformer)

  • 최연석;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.174-177
    • /
    • 2003
  • Cooling load from the top plate to L$N_2$ surface, including wall conduction, gas conduction, radiation, and current leads, is investigated in a closed cooling system for HTS transformer. In general methods of load calculation, individual load is estimated separately, but they are actually coupled each other because of natural convection of nitrogen vapor. Using heat transfer analysis, we calculate cooling load with taking into account the effect of natural convection. Cooling load is under- estimated approximately 2 % when the natural convection is ignored. If the operating current is high, there will be a wide difference between actual cooling load and cooling load by individual calculation. Cooling load decreases with increasing number of radiation shield. With production, construction, and cooling load, three radiation shields are proper to 1 MVA HTS transformer.

  • PDF

Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

  • Hedayat, Afshin
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.953-967
    • /
    • 2017
  • In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal-hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

극저온용기 액체헬륨 표면 상부의 열전달 특성 (Heat Transfer above Liquid Helium Surface in Cryostat)

  • 최연석;김동락;신동원
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.147-152
    • /
    • 2011
  • The cryogenic cooling load from the top plate of cryostat to liquid helium surface, including wall conduction, thermal radiation and current leads, is investigated in a closed cryostat system for superconducting magnet. In general methods of load estimation, individual load is calculated separately, however they are actually coupled each other because of natural convection of helium vapor. Using relevant heat transfer analysis, we calculate cryogenic load with taking into account the effect of natural convection. Cryogenic load is under-estimated approximately 1% when the natural convection is ignored. The difference between actual cooling load and cooling load by individual calculation increases with supplying current.

자연대류를 고려한 초전도 전류도입선의 최적 설계 (Optimal design of HTS current lead considering natural convection)

  • 손봉준;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.269-273
    • /
    • 2003
  • In this paper the HTS current lead for superconducting device is studied numerical method. The current lead is cooled by surrounded He gas by natural convection. To find wall heat flux, the linearization method is adopted Numerical results using natural convection cooling are compared with conventional cooling methods such as conduction cooling and vapor cooling. The results shows that the minimum heat dissipation is much smaller than conduction cooling. Also, the minimum heat dissipation is obtained for the non-zero gradient of temperature at warm end. HTS current lead operating current sharing mode is reduce heat flow to superconducting system.

  • PDF

Two Dimensional Analysis for the External Vessel Cooling Experiment

  • Yoon, Ho-Jun;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.410-423
    • /
    • 2000
  • A two-dimensional numerical model is developed and applied to the LAVA-EXV tests performed at the Korea Atomic Energy Research Institute (KAERI) to investigate the external cooling effect on the thermal margin to failure of a reactor pressure vessel (RPV) during a severe accident. The computational program was written to predict the temperature profile of a two-dimensional spherical vessel segment accounting for the conjugate heat transfer mechanisms of conduction through the debris and the vessel, natural convection within the molten debris pool, and the possible ablation of the vessel wall in contact with the high temperature melt. Results of the sensitivity analysis and comparison with the LAVA-EXV test data indicated that the developed computational tool carries a high potential for simulating the thermal behavior of the RPV during a core melt relocation accident. It is concluded that the main factors affecting the RPV failure are the natural convection within the debris pool and the ablation of the metal vessel, The simplistic natural convection model adopted in the computational program partly made up for the absence of the mechanistic momentum consideration in this study. Uncertainties in the prediction will be reduced when the natural convection and ablation phenomena are more rigorously dealt with in the code, and if more accurate initial and time-dependent conditions are supplied from the test in terms of material composition and its associated thermophysical properties.

  • PDF

밀폐된 공간 내 공랭식 PEMFC의 자연대류 열전달에 대한 실험적 연구 (An Experimental Study on the Natural Convection Heat Transfer of Air-cooling PEMFC in a Enclosure)

  • 이준식;김승곤;손영준
    • 한국수소및신에너지학회논문집
    • /
    • 제27권1호
    • /
    • pp.42-48
    • /
    • 2016
  • This study presents an experiment investigation on natural convection heat transfer of air-cooling Proton exchange membrane fuel cells (PEMFCs) in a enclosure system for unmanned aerial vehicles (UAVs). Considered are replacing fuel cell stack with Aluminum block for heat generating inside a enclosure chamber. The volume ratio of fuel cell stack and chamber for simulation to the actual size of aerial vehicle is 1 to 15. The parameters considered for experimental study are the environmental temperature range from $25^{\circ}C$ to $-60^{\circ}C$ and the block heat input of 10 W, 20 W and 30 W. Effect of the thermal conductivity of the block and power level on heat transfer in the chamber are investigated. Experimental results illustrate the temperature rise at various locations inside the chamber as dependent upon heat input of fuel cell stack and environmental temperature. From the results, dimensionless correlation in natural convection was proposed with Nusselt number and Rayleigh number for designing air-cooling PEMFC powered high altitude long endurance (HALE) UAV.

이중원관의 냉각과정에 미치는 과냉각의 영향 (Effect of supercooling on the cooling in horizontal cylindrical annuli)

  • 윤정인;김재돌
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3313-3321
    • /
    • 1996
  • A fundamental study in cooling and solidification process focused on ice storage was performed, including the interesting phenomena of density inversion, supercooling and dendritic ice. A numerical study was performed for natural convection and ice formation in the cooling and freezing processes with supercooling in a space between double cylinders. When water was cooled under the freezing point by a cooling wall in a cavity, solidification was not started at once, but a subcooled region was formed near the wall. Especially, when the cooling rate was low, subcooled region extended to a wide area. However, after a few minutes, supercooling is released by some triggers. Dendritic ice is suddenly formed within a subcooled region, and a dense ice layer begins to be developed from the cooling wall. Due to the difficulties, most previous studies on solidification process with numerical methods had not treated the supercooling phenomena, i.e. the case considering only the growth of dense ice. In this study, natural convection and ice formation considering existence of supercooling and dendritic ice were analyzed numerically with using finite difference method and boundary fixing method. The results of numerical analysis were well compared with the experimental results.

변압기 냉각 특성 해석 (Cooling Characteristic Analysis of Transformer's Radiator)

  • 김현재;양시원;김원석;권기영;이민제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1920-1925
    • /
    • 2007
  • A transformer is a device that changes the current and voltage by electricity induced between coil and core steel, and it is composed of metals and insulating materials. In the core of the transformer, the thermal load is generated by electric loss and the high temperature can make the break of insulating. So we must cool down the temperature of transformer by external radiators. According to cooling fan's usage, there are two cooling types, OA(Oil Natural Air Natural) and FA(Oil Natural Air Forced). For this study, we used Fluent 6.2 and analyzed the cooling characteristic of radiator. we calculated 1-fin of detail modeling that is similar to honeycomb structure and multi-fin(18-fin) calculation for OA and FA types. For the sensitivity study, we have different positions(side, under) of cooling fans for forced convection of FA type. The calculation results were compared with the measurement data which obtained from 135.45/69kV ultra transformer flowrate and temperature test. The aim of the study is to assess the Fluent code prediction on the radiator calculation and to use the data for optimizing transformer radiator design.

  • PDF