• 제목/요약/키워드: National standard

검색결과 12,543건 처리시간 0.041초

브리넬 경도 표준 시험기 및 압입 자국 자동 측정장치의 특성 평가에 대한 연구 (A Study on the Evaluation of Brinell Standard Hardness Tester and Automatic Indentation Measurement System)

  • 방건웅;탁내형
    • 열처리공학회지
    • /
    • 제12권4호
    • /
    • pp.294-302
    • /
    • 1999
  • Evaluation of Brinell standard hardness tester was carried out to secure its application as a national standard for Brinell hardness. Accuracies and reliabilities in load application, indenter diameter and indentation measurement were tested through evaluation of these components. The accuracies of load application for various loading conditions were within the limit of ISO and KS specifications. Errors in the indentation measurement due to the difference in personnel characters were successfully removed by utilising automatic indentation measurement system. In overall, the tester and the indentation measuring system were found to be eligible as a national standard of Brinell hardness.

  • PDF

수돗물에서 미량유해물질의 체계적 관리방안 연구 (The Systematic Management for Trace Hazard Compounds in Drinking Water)

  • 박선구;임연택
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.431-441
    • /
    • 2005
  • The study was carried out to improve and regulate the drinking water quality standard and drinking water quality monitoring substances. For the reliability and safety of finished water, It has been monitored for trace organic and inorganic compounds of 333 in finished water of water treatment plants during 1989 to 2003. As a result of monitoring, 51 compounds were detected from 333 compounds, and it has been regulated the drinking water quality standard of 26 substances and 20 mitoring substance. Improvement and regulation method of the drinking water quality standard was performed by comparing and analyzing with detection concentration, detection frequency, risk assessment and foreign drinking water quality standard.

Spiral 인덕터 간 격리방법에 따른 Electromagnetic 커플링 효과 (EM Coupling Effect of sprint inductors by isolation methode in standard CMOS process)

  • 최문호;김한석;정성일;김영석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.91-92
    • /
    • 2005
  • The electromagnetic coupling effect in standard CMOS process is simulated and evaluated. EM coupling transfer characteristic between planar spiral inductors by isolation methode in standard CMOS have simulated and measured. Measurement results show that suppression of EM coupling effect by ground guardring. The evaluated structures are fabricated 1P5M(one poly, five metal) 0.25um standard CMOS process. These measurement results provide a isolation design guidelines in standard CMOS process for Rf coupling suppression.

  • PDF

온열환경기준에 따른 여름철 사무실의 열쾌적성 평가 (A Field Survey of Thermal Comfort in Office Building with Thermal Environment Standard)

  • 공효주;윤근영;김정태
    • KIEAE Journal
    • /
    • 제11권3호
    • /
    • pp.37-42
    • /
    • 2011
  • This study aims to analyze the field survey of thermal comfort in office building with national thermal environment standard. Internal and external temperatures were measured at ten minute intervals and compared in accordance with the national standard for thermal environment. Sixty two workers filled in the questionnaire survey forms five times a day for 40 days. Field monitoring of offices in Seoul, Korea were conducted from 20 July to 28 August. Result for the comfort temperature was set a $26.30^{\circ}C$. This indicates that the 26 degree is reliable for the Korean standard. Indoor temperature standard can reduce energy use by air-conditioned buildings and the temperature would be offer comfort to occupants.

휠체어사용자용 화장실의 규격기준에 대한 연구 (A Study on Standards of Wheelchair User Accessible Toilet Rooms)

  • 신동홍;박광재
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권4호
    • /
    • pp.27-35
    • /
    • 2018
  • Purpose: The diverse users and the increase of power wheelchair users have made it difficult to apply the standards of Wheelchair user accessible toilet rooms for the existing law and BF-certification. To address these issues, the standards of the relevant laws have been improved (Ministry of Health and Welfare, 2018), but there are still many problems. In this study, problems with the standards for Wheelchair user accessible toilet rooms in Korea are analyzed by comparing national and international standards. In addition, improvements to standards for Wheelchair user accessible toilet rooms will be suggested. Method: It presents improvement for standards of Wheelchair user accessible toilet rooms by comparing national, international standard and standards of many countries. Korean standard, International Standard(ISO 21542), American Standard(ADA Standards), German Standard(DIN 18040-1), Austrian Standard($\ddot{O}NORM$ B 1600) and Swiss Standard(Norm SIA 500) were investigated and analyzed. Results: Korea's standards differ from the ISO and the Standards of other countries in many ways, so there is a need for realignment. Specifications for disabled toilets and clear criteria for the size, shape, and location of sanitary appliances in toilets that are practically available to wheelchair users should be provided. Considering the increasing number of disabled toilet users, the installation of various disabled toilet rooms should be considered considering the user characteristics of those who can walk and wheelchair users. Implication: Recent partial improvements to relevant laws cannot meet the requirements of various users. Therefore, comprehensive and clear standard should be presented that take into account changing society and the environment.

On the STSP Normal Distribution

  • Choi, Jeen-Kap
    • Journal of the Korean Data and Information Science Society
    • /
    • 제16권2호
    • /
    • pp.451-456
    • /
    • 2005
  • We introduce the standard two-sided power normal distribution and consider the relation between the probability in standard two-sided power distribution and the probability in standard two-sided power normal distribution and obtain the even moment of the special two-sided power normal distribution including the cases considered by Gupta and Nadarajah(2004)

  • PDF

대형마트 공급자평가에 대응하기 위한 수산양식장 인증제도 개선에 관한 연구 (A Study on the Improvement of Aquaculture Certification System to Meet Greater Retailer's Supplier Assesment Requirement)

  • 서종석;서원철;옥영석
    • 수산경영론집
    • /
    • 제45권1호
    • /
    • pp.33-47
    • /
    • 2014
  • The purpose of this study is to find method to meet the greater retailer's supplier assessment requirement So, this study analyze the greater retailer's requirement for supplier assesment and research global standard which is used instead of supplier assessment requirement that is recognized by global retailers initiative. Next, this study analyze domestic aquaculture certification requirement and compare the global standard with the domestic requirement by using The Most Similar Systems Design. As a result, this comparing has founded all of two domestic certifications are similar to global standard's Good Aquaculture Practice module but those are a little bit different from System Element module. Therefore, this study suggest tree alternative. First, make up for the weak points in the current domestic aquaculture certification system. Second, the introduction of global aquaculture management system certification as supporting by government. Third, development of new standard in accordance with global food standard. This study has major implications for research into development of domestic aquaculture standard.

Review on the New Fire Protection Standard for Nuclear Power Plants and Investigation for the Applicability of the Performance-Based Fire Modeling

  • Jee, Moon-Hak;Hong, Sung-Yull;Sung, Chang-Kyung;Kim, In-Hwang
    • Nuclear Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.259-267
    • /
    • 2002
  • NFPA-803 has been referred as the Fire Protection Standard at the Nuclear Power Plants of Pressurized Water Reactor. This Standard has been used as the fire protection regulation, containing prescriptive requirements with deterministic methodology. Recently, with cumulative efforts by the U.S. Nuclear Regulatory Commission and Utilities in America to establish a new Standard, including a quantitative evaluation methodology, NFPA-805, the Performance-Based Standard for FIRE Protection for Light Water Reactor Electric Generating Plants was issued and approved by the American National Standards Institute as an American National Standard with an effective date of February 9, 2001. This paper presents an analysis result from the computer modeling for the fire simulation In addition, it proposes the idea that this kind of analytic method can be available for the facilities design of fire prevention and protection fields, as well as an evaluation for the fire suppression system with a quantitative analysis for the thermal phenomena in fire compartments in Nuclear Power Plants.

압전소자를 이용한 에너지 하베스터용 전력변환장치 연구 (A Study of Power Conversion System for Energy Harvester Using a Piezoelectric Materials)

  • 안현성;김영철;차한주
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1059-1065
    • /
    • 2017
  • In this paper, the energy harvester with a piezoelectric materials is modeled as the electric equivalent circuit, and performances of a standard DC method and a Parallel-SSHI method are verified through experiment under variable force and load conditions. Piezoelectric generator consists of mass, damper and spring constant, and it is modeled by electrical equivalent circuit with RLC components. Standard DC and Parallel-SSHI are used as power conversion methods, and standard DC consists of full-bridge rectifier and smoothing capacitor. Parallel-SSHI method is composed of L-C resonant circuit, zero-crossing detector and full-bridge rectifier. In case of simulation under $100k{\Omega}$ load condition, the harvested power is $500{\mu}W$ in Standard DC and $670{\mu}W$ in Parallel-SSHI, respectively. In experiment, the harvested power under $100k{\Omega}$ load condition is $420{\mu}W$ in standard DC and $602{\mu}W$ in Parallel-SSHI. Harvested power of Parallel-SSHI is improved by approximately 40% more than that of standard DC method.