• Title/Summary/Keyword: National Safety

Search Result 15,579, Processing Time 0.045 seconds

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Toxicity Test of Carbosulfan and Phenthoate on Killifish (Carbosulfan과 Phenthoate의 송사리(Oryzias latipes, Medaka)에 대한 독성시험)

  • Bae, Chul-Han;Lee, Jeong-Seok;Cho, Kyung-Won;Park, Hyun-Ju;Cho, Dong-Hun;Shin, Kwan-Seop;Jung, Chang-Kook;Park, Yeon-Ki
    • The Korean Journal of Pesticide Science
    • /
    • v.8 no.4
    • /
    • pp.309-318
    • /
    • 2004
  • Acute toxicity test and chronic toxicity test were conducted with killifish (Oryzias latipes, Medaka) to evaluate toxicity effect of pesticides. Acute toxicity test was investigated mortality in 48 hours and 96 hours after treatment, chronic toxicity test was examined with the early life stage of 30 days after hatching be started embryos of Medaka. The test substances were two pesticides, Carbosulfan and Phenthoate, applied to the paddy rice plant and well-known to the high fish toxicity. As the result of acute toxicity test, median concentration $(LC_{50})$ at 96 hours in Medata was Carbosulfan 0.102 mg/L and Phenthoate 0.167 mg/L, and Fish early life stage toxicity test was conducted on basis of the result of acute toxicity test and concluded from the investigation of hatching success, period of hatching, survival post hatching, length and weight of surviving fishes and abnormal fish. The results of early life stage toxicity test were represented by no observed effect concentration (NOEC), lowest observed effect concentration (LOEC) and maximum acceptable toxicant concentration (MATC). NOEC was Carbosulfan 0.0067ppm and Phenthoate 0.011ppm, LOEC of PCP-Na, Carbosulfan and Phenthoate were 0.017ppm and 0.029ppm, MATC of Carbosulfan and Phenthoate were 0.011ppm and 0.018ppm. These studies will be expected to supply more varied chronic toxicity effects at lower concentration than acute toxicity test. Therefore, evaluation data will be more realistic and the risk assessment of pesticide will be leveled up.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Monitoring Bacillus cereus and Aerobic Bacteria in Raw Infant Formula and Microbial Quality Control during Manufacturing (영.유아용 식품원료의 Bacillus cereus와 일반세균 모니터링 및 제조공정 중 미생물 품질제어)

  • Jung, Woo-Young;Eom, Joon-Ho;Kim, Byeong-Jo;Ju, In-Sun;Kim, Chang-Soo;Kim, Mi-Ra;Byun, Jung-A;Park, You-Gyoung;Son, Sang-Hyuck;Lee, Eun-Mi;Jung, Rae-Seok;Na, Mi-Ae;Yuk, Dong-Yeon;Gang, Ji-Yeon;Heo, Ok-Sun;Yoon, Min-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.494-501
    • /
    • 2010
  • The purpose of this study was to examine the presence of Bacillus cereus, aerobic bacteria and coliforms in the raw material of infant formulas and investigate the manufacturing process in terms of microbial safety. Among ten kinds of raw infant formula material samples (n=20), Bacillus cereus appeared in two (n=4). Aerobic bacteria were not detected in raw infant formula material or maximum 4.15 log CFU/g. Eleven species of aerobic bacteria were isolated and 76% of them were Sphingomonas paucimobilis, Pseudomonas fluorescens, Rhizobium radiobactor, or Stenotrophomonas maltophilia. A Pearson's correlation analysis revealed that the most influential factors for detecting Bacillus cereus were aerobic bacteria and coliforms. In other words, when the measured values of aerobic bacteria and coliforms were higher, the possibility that Bacillus cereus would appear increased. In a regression model to predict Bacillus cereus, the rate of appearance was correlated with aerobic bacteria and coliforms, and its contribution rate for effectiveness was 86%. Improving microbial quality control by pasteurization, spray dry, popping and extrusion resulted in a decrease in the numbers of Bacillus cereus, aerobic bacteria and coliforms in the raw materials. The results suggest that a hazard analysis and critical control point system might be effective for reducing microbiological contamination.

Changes in Quality of Fried Rice with Red Snow Crab Meat Depending on the Storage Period and Temperature (저장기간 및 저장온도에 따른 붉은대게풍미 볶음밥의 품질변화)

  • Jung, Ji Hee;Lim, Ji Hoon;Jeong, Min Jeong;Jeong, In Hack;Kim, Byoung Mok
    • Korean journal of food and cookery science
    • /
    • v.31 no.4
    • /
    • pp.387-394
    • /
    • 2015
  • The red snow crab lives at a depth 200-2,000 m in the east coast. It has a smooth taste with a rich texture. However mostly red snow crab are only utilized materials. For seafood development, research is needed on using red snow crab in various products. In this study, quality changes in fried rice prepared with red snow crab meat, red snow crab emulsion sauce and red snow crab effluent were investigated. Physicochemical, microbiological and sensory characteristics were determined during storage at -20, 4 and $25^{\circ}C$ for 5 weeks to assess changes in the quality of the fried rice. The pH and acidity values did not show any significant differences at $-20^{\circ}C$. The VBN and TBA values of fried rice stored at 4 and $25^{\circ}C$ were significantly higher than those of fried rice stored at $-20^{\circ}C$ during the same storage period. The viable cell count of the fried rice stored at $-20^{\circ}C$ changed little during the storage period. During storage at $25^{\circ}C$, the overall quality was initially 8.0, but rapidly decreased to 1.0 after 5 weeks. In conclusion, the best storage temperature for both quality and safety was $-20^{\circ}C$. The storage condition for instant rice containing red snow crab affects the quality and we confirmed the applicability of using materials from red snow crab.

Residue Study for Bisphenol A in Agricultural Reservoirs (농업용 저수지에서 Bisphenol A의 잔류실태조사)

  • Cho, Il Kyu;Nam, Hyo Song;Jeon, Yongbae;Park, Jun sung;Na, Tae Wong;Kim, Back Jong;Kan, Eunsung
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.4
    • /
    • pp.270-277
    • /
    • 2016
  • BACKGROUND: Significant amount of bisphenol A has been released from the manufacturing process of plastics, epoxy resins, dental material and flame retardants. Bisphenol A has been detected at trace levels in wastewater, surface water, landfill leachate and drinking water. However, the residual survey of bisphenol A has not been performed in agricultural reservoir beside agricultural environment cultivating crops. This study was conducted to monitor the residual bisphenol A in national agricultural reservoirs and understand a level of contamination of bisphenol A in the agricultural environment in Korea. METHODS AND RESULTS: The water and water sediment were collected at agricultural reservoirs in Chungnam, Chungbuk, Kyunggi, Jeonnam, Jeonbuk, Kyungnam and Kyungbuk province. Bisphenol A was analyzed by the LC-MS/MS with triple quad 4500. The recovery of water and water sediment in the agricultural reservoirs showed the level of 95.7~97.2% and 91.5~100.3%, respectively. CONCLUSION: Bisphenol A was detected at the level of $0.05{\mu}g/L{\sim}0.18{\mu}g/L$ and $0.1{\mu}g/kg{\sim}34{\mu}g/kg$ in water and water sediment of the reservoirs, respectively. Based on the results, the residue of bisphenol A will be tried in the crops surrounding these agricultural reservoirs where bisphenol A detected above $10{\mu}g/kg$ of bisphenol A.

A Decreasing Trend of Industrial Injuries at a Large Scale Textile Company (대기업섬유업체(大企業纖維業體)에 있어서의 산업재해감소추이(産業災害減少推移))

  • Hong, Soon-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.65-73
    • /
    • 1984
  • To assess the status of industrial injuries, a large scale textile company located around Taegu city was selected. And it was investigated from January 1981 to December 1982. After the department for workers safety was established, frequency rate of injury was 9.70 in 1981 and 4.15 in 1982, incidence rate per 1,000 workers was 27.11 in 1981 and 12.96 in 1982, and then, intensity rate was 0.33 in 1981 and 0.01 in 1982. The average duration of working loss was 36.64 days in 1981 and 3.34 in 1982. The incidence rate per 100 workers was 2.3 in annual average, 2.7 in men and 2.0 in women. The monthly incidence rate per 1,000 workers was highest as 3.6 in June; daily incidence rate, lowest as 1.8 on Sunday; and the highest as 14.7 from 10 to 12 o'clock in a day. The frequency by injured parts of body was highest as 42.3% on finger and 14.4% on the other part of hand, and the lower extremities as 14.4% followed. According to the kind of injuries, the laceration was the highest as 46.1%, the next was contusion as 15.4%, and the third was superficial injuries as 6.7%, According to the cause of injuries, the machinery accidents showed the highest as 47.1% and the accidents due to hand tool followed as 16.3%. By underlying cause of injuries, the environmental factors were 13.5% and the human factors 86.5%. The psychologic factors among human factors were the most common as 60.6%.

  • PDF

Cohort Study for the Effect of Chronic Noise Exposure on Blood Pressure among Male Workers (만성적 소음노출이 혈압에 미치는 영향에 대한 코호트연구)

  • Cha, Tae-Joon;Kim, Jang-Rak;Kang, Wee-Chang;Yaang, Seung-Rim;Lee, Choong-Ryeol;Yoo, Cheol-In;Lee, Ji-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.3
    • /
    • pp.205-213
    • /
    • 2002
  • Objective : Whether exposure to chronic noise induces an increase in blood pressure, or the development of hypertension, has not been established. A cohort study was performed to identify the effects of chronic noise exposure on blood pressure. Methods : 530 males working at a metal manufacturing factory in Busan, Korea were enrolled for the study. They were monitored for 9 consecutive years, from 1991 to 1999, with an annual health check-up. The subjects were divided into 4 groups, which were determines by noise level categories(NLC) according to noise intensity ; NLC-I: office workers, exposed to noise a level below 60dB(A) ; NLC-II: field technical supporters or supervisors, frequently exposed to workplace noise, wearing no hearing protection device; NLC-III: workers, exposed to workplace noise below 85dB(A), wearing ear plugs or muffs; NLC-IV: workers, exposed to workplace noise over 85 dB(A), wearing both ear plugs and muffs. Results : After controlling possible confoundens, such as baseline age, smoking, alcohol intake, exercise, family history of hypertension, systolic(SBP) of diastolic blood pressure(DBP) and changes in BMI (body mass index), the pooled mean for the systolic blood pressures, over the duration of the study period, were 3.8mmHg, 2.0mmHg and 1.7mmHg higher in NLC-IV, NLC-III NLC-II groups, respectively, than in the NLC-I group. There were no significant differences in the diastolic blood pressures between the groups. Conclusion : This study suggests that chronic noise exposure increases systolic blood pressure independently, among male workers.

Health Assessment of Shift Workers in a Automobile Manufacturing Plant (자동차공장 교대작업 근로자들의 건강상태평가)

  • Lee, Jung-Jeung;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.1 s.49
    • /
    • pp.103-121
    • /
    • 1995
  • An investigation on psychophysiological health and social well-being of shift workers been carried out on workers of a automobile manufacturing plant in Ulsan, for 1 month from April, 1993. This cross-sectional survey compared shift workers(n=544) with day workers(n=115). Each subject completed a questionnaire about his personal habit, background, shift schedule, sleep and eating patterns, subjective digestive symptom and psychological well-being and distress using the General Well-Being Schedule(GWB) by self administrated questionnaire that was developed for the U.S. Health and Nutrition Examination Surveys (HANES I). Chi-square analysis was used for discontinuous data and the t-test was used for continous data to determine whether differences noted between the two groups. In terms of sleep quality, a greater percentage of shift workers frequently had trouble getting back to sleep once awakend(p<0.01), and a greater percentage of shift workers awakend tired or sleepy frequently more often than day workers(p<0.05). In rating the quality of their sleep, more shift workers rated their sleep fair to poor than day workers, and greater percentage of shift workers felt tired or sleepy at work two or more times per week(p<0.01) and a much higher percentage of shift workers felt tired or sleepy after work every days(p<0.01). In terms of sleep patterns, a much higher percentage of day workers reported uninterrupted sleep per 24hours than shift workers. The shift workers reported different eating patterns from day workers but there were no statistically significant and rate of their appetite. Thirteen percent of day workers reported the best appetite but only 6.6% of shift workers had the best appetite. The gastric complaints is more frequent in shift workers than day workers(p<0.01). Among subscores in General Well-Being Schedule, anxiety, depression, positive well-being and vitality subscale of shift workers were lower than those of day workers(p<0.05) and general health and self control subscale of shift workers were lower than .those of day workers but there were no statistical significant difference. Based on these study result, it could be concluded that the shift work has significant effects on some psychophysiological conditions of the workers.

  • PDF

A study of Establishment on Radiomap that Utilizes the Mobile device Indoor Positioning DB based on Wi-Fi (Wi-Fi 기반 모바일 디바이스 실내측위 DB를 활용한 라디오맵 구축에 관한 연구)

  • Jeong, In Hun;Kim, Chong Mun;Choi, Yun Soo;Kim, Sang Bong;Lee, Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.57-69
    • /
    • 2014
  • As of 2013, Korean population density is 505 persons per $1km^2$ and is ranked 3rd place in the most densely populated countries exception of city-states. It shows clearly the population is concentrated in the city area. To fulfil this urban concentration population demand, the enlargement and complexation of buildings, subway and other underground spaces connection tendency has been intensified, and it is need to construct the indoor spatial information DB as well as the accurate indoor surveying DB to promote people's safety and social welfare. In this study, Sadang station and Incheon National Airport were aimed for the construction of Wi-Fi AP location DB and RadioMap DB by collecting the indoor AP raw datas by using mobile device and those collected results were ran through the process of verification, supplementation, and analyzation. To evaluate the performance of constructed DB, 10 points in Incheon Airport- 3rd flr in block A, and 9 points in Sadang station-B1 were selected and calculated the estimated points and ran evaluation experiment using survey positioning error, which is distance between real position and the estimated position. The result shows that Incheon international airport's average and standard deviation was separately 17.81m, 17.79m and Sadang station's average and standard deviation was separately 22.64m, 23.74m. In Sadang station's case, the areas near the exit has low performance of surveying position due to fewer visible AP points than other areas. As total datas were examined except those position, it was verified that the user's location was mapping close position in surveying positioning by using constructed DB. It means that constructed DB contains correct Wi-Fi AP locations and radio wave patterns in object region, so it is considered that the indoor spatial information service based on constructed DB would be available.