• Title/Summary/Keyword: Narrow pulse

Search Result 109, Processing Time 0.033 seconds

Detection of Deep Subsurface Cracks in Thick Stainless Steel Plate

  • Kishore, M.B.;Park, D.G.;Jeong, J.R.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.312-316
    • /
    • 2015
  • Unlike conventional Eddy Current Test (ECT), Pulsed Eddy Current (PEC) uses a multiple-frequency current pulse through the excitation coil. In the present study, the detection of subsurface cracks using a specially designed probe that allows the detection of a deeper crack with a relatively small current density has been attempted using the PEC technique. The tested sample is a piece of 304 stainless steel (SS304) with a thickness of 30mm. Small electrical discharge machining (EDM) notches were put in the test sample at different depths from the surface to simulate the subsurface cracks in a pipe. The designed PEC probe consists of an excitation coil and a Hall sensor and can detect a subsurface crack as narrow and shallow as 0.2 mm wide and 2 mm deep. The maximum distance between the probe and the defect is 28 mm. The peak amplitude of the detected pulse is used to evaluate the cracks under the sample surface. In time domain analysis, the greater the crack depth the greater the peak amplitude of the detected pulse. The experimental results indicated that the proposed system has the potential to detect the subsurface cracks in stainless steel plates.

Performance Evaluation of 2-Dimensional Light Source using Mercury-free Flat Fluorescent Lamps for LCD Backlight Applications

  • Park, Joung-Hu;Cho, Bo-Hyung;Lee, Ju-Kwang;Whang, Ki-Woong
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.164-172
    • /
    • 2009
  • Recently, 2-dimensional flat light sources have been attracting much attention for its use in LCD backlight applications because of its high luminous efficiency and uniformity. A long-gap discharge, mercury-tree flat fluorescent lamp has been developed, which shows a high brightness ($>5000\;cd/m^2$) and high luminous efficacy (60 lm/W). Additionally, it has a wide operating margin and stable driving condition with the aid of an auxiliary electrode. For driving the lamp, a narrow pulse power to maintain the glow discharge state is required. Since there has been no research for this kind of lamp driving, this paper proposes a newly developed short-pulse, high-voltage lamp-driving scheme. The proposed lamp system uses a ballast with a coupled-inductor in order to raise the short pulse voltage up to the lamp ignition level and to obtain energy-recovery action during the glow discharge mode. The operation principles are presented and also the system performances such as the lighting efficiency, spatial and angular uniformities are evaluated by hardware experiments. The results show that the proposed lighting system is a good candidate for the next-generation of LCD backlight systems.

Calculation of UWB Communication System Capacity with Timing litter (타이밍 지터를 고려한 UWB 통신 시스템 용량 계산)

  • 박장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.767-773
    • /
    • 2004
  • An UWB communication system are a promising communication technique suitable for the current trends, which are requesting communication methods with the high throughputs and very high speed. A key feature of UWB communication systems is the very narrow pulse used in transmitting the data and PPM(Pulse Position Modulation) for modulating the data. So, the timing accuracy is very important. It is very important to accurately analyze the effect of the timing jitter on the performance of UWB communication systems. In this paper, the methods of analyzing the timing jitter effects on UWB communication systems are introduced. In particular, the channel capacities with timing jitter are calculated including the multiuser access interference.

Deriving the Fourier Transforms of Pulse Signals Through the Look-up Tables (찾아보기 목록에 의한 고차 펄스의 푸리에 변환법)

  • 오용선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.3
    • /
    • pp.327-338
    • /
    • 1993
  • This paper proposes a novel method for deriving the Fourier transform pairs of high order pulses given in a generalized form. Primarily, modifying the PRS system model, we establish a new model which simplifies the process of Fourier analysis of the n-th order pulse signal, resulting in a representative relationship. In succession, we present the Frame Formula which plays a role of substituent for the parameters in table look-up procedures. Each look-up table contains all the parameters needed to obtain the Fourier transform of the corresponding pulse of any order. Regarding the amount of calculations and the complexity of procedures required to derive the transforms of pulse signals, analytically or numerically, this method is more compact and timesaving than conventional methods. When pulse has a much narrow width of equivalently higher the order of several pulses, the method presented here acts to the best of its true merit.

  • PDF

Calculations of ISO Narrow and ANSI X-Ray Spectra, Their Average Energies and Conversion Coefficients (ISO Narrow Series및 ANSI의 X선 스펙트럼, 평균에너지 및 선량환산인자의 이론적 계산)

  • Kim, Jang-Lyul;Kim, Bong-Whan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.129-136
    • /
    • 1995
  • In spite of the prescriptions on the reference X-ray fields given by the International Organization of Strandard(ISO) and American National Standard Institute(ANSI), the measurement of X-ray spectrum is not only time consuming but very difficult, paticularly when significant corrections have to be applied to the measured pulse-height distributions of the observed spectra. This paper describes the calculation method of ISO Narrow Series and ANSI X-ray filtered radiations by theoretical model which is modified framer's theory by target attenuation and backscatter correction. The X-ray spectra, average energies and conversion coefficients are calculated and compared with those obtained using the spectra prescribed by ISO and AMSI to assure good agreement.

  • PDF

IEEE 802.11a Interference Suppression Method Using by SVD Algorithm in LR-UWB Systems (LR-UWB 시스템에서 특이값 분해를 이용한 IEEE 802.11a 간섭억압기법)

  • Kim, Dong-Hee;Kim, Tae-Hun;Jang, Hong-Mo;Park, Ho-Hwan;Kwak, Kyung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1A
    • /
    • pp.74-84
    • /
    • 2008
  • UWB radio systems have drawn attention during the last few years. These systems are the core technique for ubiquitous home and enable to co-exist with other narrow band systems over the same frequency without interfering them. But UWB signals have a very low power per pulse, so they are affected by strong narrow band interferences. Specially, IEEE 802.11a systems which operate around 5GHz overlap the band of UWB signals and they will interfere with UWB systems significantly. In this paper, we propose a novel narrow band interference suppression method based on singular value decomposition(SVD) algorithm for DS-UWB in IEEE 802.15.4a channel model. The proposed method is very effective and robust for both a single user DS-UWB system and a multiuser DS-UWB system to reduce the narrow band interference.

Several systems for 1Giga bit Modem

  • Park, Jin-Sung;Kang, Seong-Ho;Eom, Ki-Whan;Sosuke, Onodera;Yoichi, Sato
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1749-1753
    • /
    • 2003
  • We proposed several systems for 1Giga bit Modem. The first, Binary ASK(Amplitude Shift Keying) system has a high speed shutter transmitter and no IF(Intermediate Frequency) receiver only by symbol synchronization. The advantage of proposed system is that circuitry is very simple without IF process. The disadvantage of proposed system are that line spectrum occurs interference to other channels, and enhancement to 4-level system is impossible due to its large SNR degradation. The second, Binary phase modulation system has a high speed shutter transmitter and IF-VCO(IF-Voltage Controlled Oscillator) control by base-band phase rotation. Polarity of shutter window is changed by the binary data. The window should be narrow same as above ASK. The advantage of proposed system is which error rate performance is superior. The disadvantage of proposed system are that Circuitry is more complex, narrow pull-in range of receiver caused by VCO and spectrum divergence by the non-linear amplifier. The third, 4-QAM(Quadrature Amplitude Modulation)system has a nyquist pulse transmitter and IF-VCO control by symbol clock. The advantage of proposed system are that signal frequency band is a half of 1GHz, reliable pull-in of VCO and possibility of double speed transmission(2Gbps) by keeping 1GHz frequency-band. The disadvantage of proposed system are that circuit complexity of pulse shaping and spectrum divergence by the non-linear amplifier.

  • PDF

Alternating Acquisition Technique for Quantification of in vitro Hyperpolarized [1-13C] Pyruvate Metabolism

  • Yang, Seungwook;Lee, Joonsung;Joe, Eunhae;Lee, Hansol;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • Purpose: To develop a technique for quantifying the $^{13}C$-metabolites by performing frequency-selective hyperpolarized $^{13}C$ magnetic resonance spectroscopy (MRS) in vitro which combines simple spectrally-selective excitation with spectrally interleaved acquisition. Methods: Numerical simulations were performed with varying noise level and $K_p$ values to compare the quantification accuracies of the proposed and the conventional methods. For in vitro experiments, a spectrally-selective excitation scheme was enabled by narrow-band radiofrequency (RF) excitation pulse implemented into a free-induction decay chemical shift imaging (FIDCSI) sequence. Experiments with LDH / NADH enzyme mixture were performed to validate the effectiveness of the proposed acquisition method. Also, a modified two-site exchange model was formulated for metabolism kinetics quantification with the proposed method. Results: From the simulation results, significant increase of the lactate peak signal to noise ratio (PSNR) was observed. Also, the quantified $K_p$ value from the dynamic curves were more accurate in the case of the proposed acquisition method compared to the conventional non-selective excitation scheme. In vitro experiment results were in good agreement with the simulation results, also displaying increased PSNR for lactate. Fitting results using the modified two-site exchange model also showed expected results in agreement with the simulations. Conclusion: A method for accurate quantification of hyperpolarized pyruvate and the downstream product focused on in vitro experiment was described. By using a narrow-band RF excitation pulse with alternating acquisition, different resonances were selectively excited with a different flip angle for increased PSNR while the hyperpolarized magnetization of the substrate can be minimally perturbed with a low flip angle. Baseline signals from neighboring resonances can be effectively suppressed to accurately quantify the metabolism kinetics.

The Meaning Of "In case of both Yin and Yang deficiency, treat with sweet medicinals(甘藥)" In the Huangdineijing (『황제내경(黃帝內經)』 "음양구부족자(陰陽俱不足者) 감약치지(甘藥治之)"에 대한 고찰)

  • Lyu, Jeong-ah
    • Journal of Korean Medical classics
    • /
    • v.35 no.4
    • /
    • pp.41-61
    • /
    • 2022
  • Objectives : This paper aims to examine the clinical meaning of treating with sweet medicinals where acupuncture fails, through studying the verse, "In case of both Yin and Yang deficiency, treat with sweet medicinals" in the Huangdineijing. Methods : Related contents in the chapters 「邪氣藏府病形」, 「根結」, 「終始」, 「經脈」, 「九鍼論」 of the Lingshu were analyzed threefold. The circumstances of the application of the "In case of both Yin and Yang deficiency, treat with sweet medicinals" principle to the late Han East Asian medicine as written in the Shanghanzabinglun were examined, and its meaning was explored. Results : The 'Yin Yang' in the verse could be substituted with the Five Zhang and Six Fu, Blood and Qi, Form and Qi, Form and Jing, Form and Zhi, etc. In patients with deficiency in Qi, Blood, Yin and Yang, we can observe external symptoms such as narrow pulse pattern, symptoms in the throat or below the throat, thirst, and coarse voice. To apply sweet medicinals is to supplement the Jing from food, Spleen and Stomach, Middle Qi and Earth Qi which produces and maintains Qi, Blood, Yin and Yang. Therefore, it is essential in treating disease patterns with deficiency in both Qi, Blood, Yin and Yang, and cannot be substituted with other means of treatment such as acupuncture, moxibustion, and other manipulative therapies. Conclusions : Sweet medicinals were applied in disease patterns with throat thirst and narrow pulse patterns which could not be managed with general acupuncture or moxibustion in the time of the Huangdineijing's publication, as it holds the Earth virtue which could harmoniously supplement the body's Qi, Blood, Yin, and Yang. Later its application broadened, treating various conditions accompanying Qi, Blood, Yin, Yang deficiency, which expanded potential of medicine and contributed to the generalization of drug treatment.

Echolocation Signals of Pipistrellus abramus in Relation to Environmental Type (환경특성에 따른 집박쥐의 반향정위(Echolocation) 시그널 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.6
    • /
    • pp.553-563
    • /
    • 2009
  • This study was conducted to analyze the changes in the echolocation of Pipistrellus abramus according to environmental characteristics. The survey was conducted in the day-roosting site of P. abramus located in Gyeongju City (North Gyeongsang Province) from April to August, 2009. The environmental characteristics during the research were classified in six categories: the emergence time after sunset moving time from day roost to feeding areas; rice fields; forest edges; open spaces; and residential areas. Analysis results showed that there are differences in environmental characteristics and also differences between the moving time to the habitat and the moving time to capture preys. At the emergence time from day roost, Pipistrellus abramus used a FM signal with a short pulse-duration. In open spaces, however, they used a CF signal with a long pulse-duration. In different environmental situations, they used both FM and CF signals, although the types of pulse which they used were different. Except pulse-duration, there were significant differences in pulse-interval, peak-frequency, starting-frequency and ending-frequency between the movement among habitats and the movement to capture preys. Except the emergence time from day-roost, they showed a narrow band FM signal and a long pulse-duration that are suitable to search for insects by sensing echoes of insects when they moved among their habitats. When they were out to capture their preys, they showed a broad band FM signal and a short pulse-duration which enabled them to widely search and accurately locate their preys.