• 제목/요약/키워드: Nanohybrid composite

검색결과 18건 처리시간 0.021초

Effect of dentin roughening and type of composite material on the restoration of non-carious cervical lesions: an in vivo study with 18 months of follow-up

  • Sanjana Verma;Rakesh Singla;Gurdeep Singh Gill;Namita Jain
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.35.1-35.14
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the impact of dentin roughening and the type of composite resin used (either bulk-fill flowable or nanohybrid) on the restoration of non-carious cervical lesions (NCCLs) with an 18-month follow-up period. Materials and Methods: This prospective split-mouth study included 36 patients, each with a minimum of 4 NCCLs. For each patient, 4 types of restorations were performed: unroughened dentin with nanohybrid composite, unroughened dentin with bulk-fill flowable composite, roughened dentin with nanohybrid composite, and roughened dentin with bulk-fill flowable composite. A universal bonding agent (Tetric N Bond Universal) was applied in self-etch mode for all groups. The restorations were subsequently evaluated at 6, 12, and 18 months in accordance with the criteria set by the FDI World Dental Federation. Inferential statistics were computed using the Friedman test, with the level of statistical significance established at 0.05. Results: The 4 groups exhibited no significant differences in relation to fracture and retention, marginal staining, marginal adaptation, postoperative hypersensitivity, or the recurrence of caries at any follow-up point. Conclusions: Within the limitations of the present study, over an 18-month follow-up period, no significant difference was present in the clinical performance of bulk-fill flowable and nanohybrid composite restorations of non-carious cervical lesions. This held true regardless of whether dentin roughening was performed.

복합 레진에서 마무리 방법에 따른 표면 거칠기 비교 (Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin)

  • 정숙인;오남식;이명현;이은정;조정현;지성원
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.105-115
    • /
    • 2008
  • 전치부 영역에서의 복합 레진을 이용한 수복물의 표면은 착색과 치태 침착이 적어야 하며 치은 조직에 좋은 내성을 갖도록 평활해야 한다. 레진 수복 후 여러 마무리 방법중 blade를 이용한 방법은 치은과 접해있는 변연 부위의 불필요한 레진을 제거하고 마무리하는데 있어 치은 손상을 최소화하면서 간편하게 이용할 수 있는 방법이다. 본 연구의 목적은 현재 많이 사용되고 있는 nano-hybrid composite resin과 ormocer-based compostie resin 간의 여러 가지 마무리 방법에 있어 blade를 이용한 방법과 polishing을 시행한 경우의 표면 거칠기 및 nano계열과 ormocer 계열 복합 레진의 표면 특징을 비교하는 것으로 실험을 위해 가로 6mm, 세로 3mm, 높이 2mm의 금속 주형을 이용하여 레진 블록을 형성하고 대조군은 상면에 mylar strip을 위치시켜 광중합 하였으며, Ormocer - based composite resin ($Admira^{(R)}$)과 nanohybrid composite resin ($Grandio^{(R)}$)에서는 blade를 이용한 경우와 rubber polishing을 이용한 경우를 실험군으로 하였고, ormocer-based flowable composite resin ($Admira^{(R)}$ Flow)과 nanohybrid flowable composite resin ($Grandio^{(R)}$ Flow)에서는 blade를 이용한 경우, rubber polishing을 이용한 경우와 추가적으로 아무것도 시행하지 않은 경우를 실험군으로 하였다. 레진 블록의 표면은 profilometer 및 SEM을 이용하여 거칠기 및 조도를 비교하였으며 통계분석 하였다. 실험 결과 mylar stirp을 적용한 경우 Ra (${\mu}m$) 평균 값은 ormocer-base composite resin이 $0.25{\mu}m$, ormocer-based flowable resin $0.17{\mu}m$, nanohybrid composite resin $0.24{\mu}m$, nanohybrid flowable resin $0.18{\mu}m$ 였으며 blade를 적용한 경우 평균 값은 각각 $0.43{\mu}m$, $0.37{\mu}m$, $0.48{\mu}m$, $0.41{\mu}m$ 였다. 가장 낮은 Ra (${\mu}m$)은 mylar stirp을 적용한 시편에서 얻어졌으며, blade를 이용한 마무리 방법과 rubber polishing을 시행한 경우와 표면 거칠기 비교시 Ra (${\mu}m$)값에서 통계적으로 유의한 차이를 보이지 않았다 (P>0.05). Nanohybrid composite resin이 blade로 마무리하거나 rubber polishing후 ormocer-based composite resin보다 표면 거칠기 증가율이 좀 더 큰 것을 알 수 있었다. 이상의 결과는 blade를 이용한 마무리 방법이 다른 마무리 방법을 대체할 수 있을 것이라는 것을 보여주며, 이에 따라 본 실험 결과에 한정지어 볼 때 복합레진 수복후 마무리 방법으로 blade를 이용하여 시행하는 것이 적용가능 할 것이라 생각된다.

Repair bond strength of resin composite to three aged CAD/CAM blocks using different repair systems

  • Gul, Pinar;Altinok-Uygun, Latife
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.131-139
    • /
    • 2020
  • PURPOSE. The purpose of this study is to evaluate the repair bond strength of a nanohybrid resin composite to three CAD/CAM blocks using different intraoral ceramic repair systems. MATERIALS AND METHODS. Three CAD/CAM blocks (Lava Ultimate, Cerasmart, and Vitablocks Mark II) were selected for the study. Thirty-two specimens were fabricated from each block. Specimens were randomly divided into eight groups for the following different intraoral repair systems: Group 1: control group (no treatment); Group 2: 34.5% phosphoric acid etching; Group 3: CoJet System; Group 4: Z-Prime Plus System; Group 5: GC Repair System; Group 6: Cimara System; Group 7: Porcelain Repair System; and Group 8: Clearfil Repair System. Then, nanohybrid resin composite (Tetric Evo Ceram) was packed onto treated blocks surfaces. The specimens were thermocycled before application of repair systems and after application of composite resin. After second thermal cycling, blocks were cut into bars (1 × 1 × 12 ㎣) for microtensile bond strength tests. Data were analyzed using two-way ANOVA and Tukey's HSD test (α=.05). RESULTS. Cimara System, Porcelain Repair, and Clearfil Repair systems significantly increased the bond strength of nanohybrid resin composite to all CAD/CAM blocks when compared with the other tested repair systems (P<.05). In terms of CAD/CAM blocks, the lowest values were observed in Vitablocks Mark II groups (P<.05). CONCLUSION. All repair systems used in the study exhibited clinically acceptable bond strength and can be recommended for clinical use.

The effect of red and white wine on color changes of nanofilled and nanohybrid resin composites

  • Tanthanuch, Saijai;Kukiattrakoon, Boonlert;Peerasukprasert, Thanwalee;Chanmanee, Nilobon;Chaisomboonphun, Parnchanok;Rodklai, Apisara
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.130-136
    • /
    • 2016
  • Objectives: This study investigated the effect of red and white wine on color changes of nanofilled and nanohybrid resin composite. Materials and Methods: Sixty specimens of each resin composite were prepared. Baseline data color values were recorded using a spectrophotometer. Three groups of discs (n = 20) were then alternately immersed in red, white wine, and deionized water (as a control) for twenty five minutes and artificial saliva for five minutes for four cycles. Specimens were then stored in artificial saliva for twenty two hours. This process was repeated for five days following immersion in artificial saliva for two days. Subsequently, the process was repeated again. Data were analyzed by two-way repeated ANOVA, one-way ANOVA, and Tukey's HSD. Results: Red wine caused significantly higher color change (${\Delta}E^*$ > 3.3) than did white wine and deionized water (p < 0.05). Nanohybrid resin composites had significantly more color changes than nanofilled resin composite (p < 0.05). Conclusions: The effect of red and white wine on the color changes of resin composite restorative materials depended upon the physical and chemical composition of the restorative materials and the types of wine.

Nanomechanical properties and wear resistance of dental restorative materials

  • Karimzadeh, A.;Ayatollahi, Majid R.;Nikkhooyifar, M.;Bushroa, A.R.
    • Structural Engineering and Mechanics
    • /
    • 제64권6권
    • /
    • pp.819-826
    • /
    • 2017
  • The effects of thermocycling procedure and material shade on the mechanical properties and wear resistance of resin-based dental restorative materials are investigated. The modulus of elasticity, hardness, plasticity index and wear resistance are determined for the conventional composite, the nanohybrid composite and the nanofilled dental composites. Disc-shape samples are prepared from each material to investigate the effects of thermocycling procedure on the mechanical properties and wear resistance of different types of dental restorative materials. In this respect, a group of samples is thermocycled and the other group is stored in ambient conditions. Then nano-indentation and nano-scratch tests are performed on the samples to measure their mechanical properties and wear resistance. Results show that the A1E shade of the dental nanocomposite possesses higher modulus of elasticity and hardness values compared to the two other shades. According to the experimental results, the mean values for the modulus of elasticity and hardness of the A1E shade of the nanocomposite are 13.71 GPa and 1.08 GPa, respectively. The modulus of elasticity and hardness of the conventional dental composite increase around 30 percent in the oral environment due to the moisture and temperature changes. The wear resistance of the dental composites is also significantly affected by moisture and temperature changes in the oral conditions. It is observed that thermocycling has no significant effect on the hardness, plasticity index and wear resistance of the nanohybrid composite and the nanocomposite dental materials.

Wear of contemporary dental composite resin restorations: a literature review

  • Dimitrios Dionysopoulos;Olga Gerasimidou
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.18.1-18.13
    • /
    • 2021
  • Composite resins are the most commonly used dental restorative materials after minimally invasive dental procedures, and they offer an aesthetically pleasing appearance. An ideal composite restorative material should have wear properties similar to those of tooth tissues. Wear refers to the damaging, gradual loss or deformation of a material at solid surfaces. Depending on the mechanism of action, wear can be categorized as abrasive, adhesive, fatigue, or corrosive. Currently used composite resins cover a wide range of materials with diverse properties, offering dental clinicians multiple choices for anterior and posterior teeth. In order to improve the mechanical properties and the resistance to wear of composite materials, many types of monomers, silane coupling agents, and reinforcing fillers have been developed. Since resistance to wear is an important factor in determining the clinical success of composite resins, the purpose of this literature review was to define what constitutes wear. The discussion focuses on factors that contribute to the extent of wear as well as to the prevention of wear. Finally, the behavior of various types of existing composite materials such as nanohybrid, flowable, and computer-assisted design/computer-assisted manufacturing materials, was investigated, along with the factors that may cause or contribute to their wear.

탄소나노튜브(CNT)의 첨가에 따른 TiO2의 광촉매 특성 변화 연구 (Evaluation of TiO2 Photocatalytic Activity with Addition of Carbon Nanotube)

  • 여인철;강인철
    • 한국분말재료학회지
    • /
    • 제23권6호
    • /
    • pp.458-465
    • /
    • 2016
  • A $TiO_2$/CNT nanohybrid photocatalyst is synthesized via sol-gel route, with titanium (IV) isopropoxide and multi-walled carbon nanotubes (MWCNTs) as the starting materials. The microstructures and phase constitution of the nanohybrid $TiO_2$/CNT (0.005wt%) samples after calcination at $450^{\circ}C$, $550^{\circ}C$ and $650^{\circ}C$ in air are compared with those of pure $TiO_2$ using field-emission scanning electron microscopy and X-ray diffraction, respectively. In addition, the photocatalytic activity of the nanohybrid is compared with that of pure $TiO_2$ with regard to the degradation of methyl orange under visible light irradiation. The $TiO_2$/CNT composite exhibits a fast grain growth and phase transformation during calcination. The nanocomposite shows enhanced photocatalytic activity under visible light irradiation in comparison to pure $TiO_2$ owing to not only better adsorption capability of CNT but also effective electron transfer between $TiO_2$ and CNTs. However, the high calcination temperature of $650^{\circ}C$, regardless of addition of CNT, causes a decrease in photocatalytic activity because of grain growth and phase transformation to rutile. These results such as fast phase transformation to rutile and effective electron transfer are related to carbon doping into $TiO_2$.

Effect of different denture cleansers on surface roughness and microhardness of artificial denture teeth

  • Yuzugullu, Bulem;Acar, Ozlem;Cetinsahin, Cem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.333-338
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the effects of different denture cleansers on the surface roughness and microhardness of various types of posterior denture teeth. MATERIALS AND METHODS. 168 artificial tooth specimens were divided into the following four subgroups (n=42): SR Orthotyp PE (polymethylmethacrylate); SR Orthosit PE (Isosit); SR Postaris DCL (double cross-linked); and SR Phonares II (nanohybrid composite). The specimens were further divided according to the type of the denture cleanser (Corega Tabs (sodium perborate), sodium hypochlorite (NaOCl), and distilled water (control) (n=14)) and immersed in the cleanser to simulate a 180-day immersion period, after which the surface roughness and microhardness were tested. The data were analyzed using the Kruskal-Wallis test, Conover's nonparametric multiple comparison test, and Spearman's rank correlation analysis (P<.05). RESULTS. A comparison among the denture cleanser groups showed that NaOCl caused significantly higher roughness values on SR Orthotyp PE specimens when compared with the other artificial teeth (P<.001). Furthermore, Corega Tabs resulted in higher microhardness values in SR Orthotyp PE specimens than distilled water and NaOCl (P<.005). The microhardness values decreased significantly from distilled water, NaOCl, to Corega Tabs for SR Orthosit PE specimens (P<.001). SR Postaris DLC specimens showed increased microhardness when immersed in distilled water or NaOCl when compared with immersion in Corega Tabs (P<.003). No correlation was found between surface roughness and microhardness (r=0.104, P=.178). CONCLUSION. NaOCl and Corega Tabs affected the surface roughness and microhardness of all artificial denture teeth except for the new generation nanohybrid composite teeth.

Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks

  • Koc-Vural, Uzay;Baltacioglu, Ismail;Altinci, Pinar
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.118-124
    • /
    • 2017
  • Objectives: This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods: Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between $5-55^{\circ}C$, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex ($Colt\grave{e}ne/Whaledent$), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at $37^{\circ}C$. The color differences (${\Delta}E$) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (${\alpha}=0.05$). Results: Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions: Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.

The effect of preheating resin composites on surface hardness: a systematic review and meta-analysis

  • Elkaffas, Ali A.;Eltoukhy, Radwa I.;Elnegoly, Salwa A.;Mahmoud, Salah H.
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.41.1-41.13
    • /
    • 2019
  • Objectives: This paper presents a systematic review and meta-analysis of the effect of preheating on the hardness of nanofilled, nanoceramic, nanohybrid, and microhybrid resin composites. Materials and Methods: An electronic search of papers on MEDLINE/PubMed, ScienceDirect, and EBSCOhost was performed. Only in vitro studies were included. Non-English studies, case reports, clinical trials, and review articles were excluded. A meta-analysis of the reviewed studies was conducted to quantify differences in the microhardness of the Z250 microhybrid resin composite using the Comprehensive Meta-Analysis software. Results: Only 13 studies met the inclusion criteria for this systematic review. The meta-analysis showed that there were significant differences between the non-preheated and preheated modes for both the top and bottom surfaces of the specimens (p < 0.05). The microhardness of the Z250 resin composite on the top surface in the preheated mode (78.1 ± 2.9) was higher than in the non-preheated mode (67.4 ± 4.0; p < 0.001). Moreover, the microhardness of the Z250 resin composite on the bottom surface in the preheated mode (71.8 ± 3.8) was higher than in the non-preheated mode (57.5 ± 5.7, p < 0.001). Conclusions: Although the results reported in the reviewed studies showed great variability, sufficient scientific evidence was found to support the hypothesis that preheating can improve the hardness of resin composites.