• Title/Summary/Keyword: Nano-level

Search Result 493, Processing Time 0.027 seconds

The Synthesis of Eu3+ Doped with TiO2 Nano-Powder and Application as a Pesticide Sensor

  • Yao, Fei;Sun, Yang;Tan, Chunlei;Wei, Song;Zhang, Xiaojuan;Hu, Xiaoyun;Fan, Jun
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.6
    • /
    • pp.932-935
    • /
    • 2011
  • Using tetrabutyl titanate as precursor, $Eu^{3+}$ doped $TiO_2$ nano-powder was prepared by sol-gel method, the nature of luminescence of nano-powder was studied. The interaction of chlorpyrifos with $Eu^{3+}$ doped $TiO_2$ was studied by absorption and fluorescence spectroscopy. The results indicated the fluorescence intensity of $Eu^{3+}$ doped $TiO_2$ was quenched by chlorpyrifos and the quenching rate constant ($k_q$) was $1.24{\times}10^{11}\;L/mol{\cdot}s$ according to the Stern-Volmer equation. The dynamics of photoinduced electron transfer from chlorpyrifos to conduction band of $TiO_2$ nanoparticle was observed and the mechanism of electron transfer had been confirmed by the calculation of free energy change (${\Delta}G_{et}$) by applying Rehm-Weller equation as well as energy level diagram. A new rapid method for detection of chlorpyrifos was established according to the fluorescence intensity of $Eu^{3+}$ doped $TiO_2$ was proportional to chlorpyrifos concentration. The range of detection was $5.0{\times}10^{-10}-2.5{\times}10^{-7}mol/L$ and the election limit ($3{\sigma}$) was $3.2{\times}10^{-11}$ mol/L.

A Kinetic Study on Aminolysis of S-4-Nitrophenyl Thiobenzoate in H2O Containing 20 mol % DMSO and 44 wt % EtOH: Effect of Medium on Reactivity and Mechanism

  • Ahn, Jung-Ae;Park, Youn-Min;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.214-218
    • /
    • 2009
  • Second-order rate constants ($k_N$) have been measured for nucleophilic substitution reactions of S-4-nitrophenyl thiobenzoate with a series of alicyclic secondary amines in $H_2O$ containing 20 mol % DMSO at 25.0 ${\pm}$ 0.1 ${^{\circ}C}$. The Br$\phi$nsted-type plot exhibits a downward curvature, i.e., $\beta_{nuc}$ decreases from 0.94 to 0.34 as the amine basicity increases. The reactions in the aqueous DMSO have also been suggested to proceed through a zwitterionic tetrahedral intermediate (T${\pm}$) with change in the RDS on the basis of the curved Br$\phi$nsted-type plot. The reactions in the aqueous DMSO exhibit larger $k_N$ values than those in the aqueous EtOH. The macroscopic rate constants ($k_N$) for the reactions in the two solvent systems have been dissected into the microscopic rate constants ($k_1\;and\;k_2/k_{-1}$ ratio) to investigate effect of medium on reactivity in the microscopic level. It has been found that the $k_2/k_{-1}$ ratios are similar for the reactions in the two solvent systems, while $k_1$ values are larger for the reactions in 20 mol % DMSO than for those in 44 wt % EtOH, indicating that the larger $k_1$ is mainly responsible for the larger $k_N$. It has been suggested that the transition state is more stabilized in 20 mol % DMSO through mutual polarizability interaction than in 44 wt % EtOH through H-bonding interaction.

An Optical Microswitch Integrated with Silicon Waveguides, Micromirrors, and Electrostatic Touch-Down Beam Actuators (실리콘 광도파로, 미소거물 및 접촉식 정 전구동기가 집적된 광스위치)

  • Jin, Yeong-Hyeon;Seo, Gyeong-Seon;Jo, Yeong-Ho;Lee, Sang-Sin;Song, Gi-Chang;Bu, Jong-Uk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.639-647
    • /
    • 2001
  • We present an integrated optical microswitch, composed of silicon waveguides, gold-coaled silicon micromirrors, and electrostatic contact actuators, for applications to the optical signal transceivers. For a low switching voltage, we modify the conventional curled electrode microactuator into a electrostatic microactuator with touch-down beams. We fabricate the silicon waveguides and the electrostatically actuated micromirrors using the ICP etching process of SOI wafers. We observe the single mode wave propagation through the silicon waveguide with the measured micromirror loss of $4.18\pm0.25dB$. We analyze major source of the micromirror loss, thereby presenting guidelines for low-loss micromirror designs. From the fabricated microswitch, we measure the switching voltage of 31.74V at the resonant frequency of 6.89kHz. Compared to the conventional microactuator, the present contact microactuator achieves 77.4% reduction of the switching voltage. We also discuss a feasible method to reduce the switching voltage to 10V level by using the electrode insulation layers having the residual stress less than 30MPa.

  • PDF

Application of Data Acquisition System for MES (MES 구현을 위한 현장정보 수집시스템의 적용 예)

  • Lee, Seung-Woo;Lee, Jai-Kyung;Nam, So-Jung;Park, Jong-Kweon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1063-1070
    • /
    • 2011
  • The manufacturing execution system (MES) for product production handles different production processes according to the product characteristics and different types of data according to the process being considered. For efficiently providing the data pertaining to production equipment to production systems such as the MES, data collection through the equipment interface is required for obtaining the production data pertaining to field equipment. In this paper, a method is proposed for collecting the production data through the equipment interface in order to collect the various types of production-equipment data from the field. The proposed method is applied to a real manufacturing system to verify its efficiency. A more powerful MES can be constructed with a data acquisition system that acquires the status data at the shop-floor level.

Association between oxidative stress and blood pressure in Korean subclinical hypertensive patients (경계성 고혈압 환자에서 혈압과 산화 스트레스 관련 지표 간의 상관성에 관한 연구)

  • Han, Jeong-Hwa;Lee, Hye-Jin;Choi, Hee Jeong;Yun, Kyung Eun;Kang, Myung-Hee
    • Journal of Nutrition and Health
    • /
    • v.46 no.2
    • /
    • pp.126-136
    • /
    • 2013
  • This study was conducted in order to investigate the association between hypertension and oxidative stress-related parameters and to evaluate these parameters in subclinical hypertensive patients and normotensive subjects living in Korea. We attempted to determine whether oxidative stress-related parameters would differ between two groups of 227 newly-diagnosed, untreated (systolic blood pressure (BP) ${\geq}$ 130 mmHg and diastolic BP ${\geq}$ 85 mmHg) and 130 normotensive subjects (systolic BP < 120 mmHg and diastolic BP < 80 mmHg). General characteristics of the subjects were collected using a simple questionnaire. From subjects' blood, degree of DNA damage in lymphocytes, the activities of erythrocyte superoxide dismutase, catalase, and glutathione peroxidase, level of plasma total radical-trapping antioxidant potential (TRAP), glutathione, and anti-oxidative vitamins, as well as plasma lipid profiles and conjugated diene (CD) were analyzed. Evaluation of the associations of oxidative stress-related parameters with blood pressure of the subjects was performed using Pearson partial correlation and multivariate logistic regression analysis after adjusting for confounding factors. Several oxidative stress-related parameters were higher in subclinical hypertensive patients than in normotensive subjects. Plasma levels of ${\alpha}$-tocopherol, ${\beta}$-carotene, TRAP, and activity of GSH-px were significantly lower in subclinical hypertensive patients than in normotensive subjects. Increased levels of DNA damage, lipid peroxidation, triglyceride, total cholesterol, and LDL-cholesterol were observed in subclinical hypertensive patients. These results confirm an association between blood pressure and oxidative stress-related parameters and suggest that the pathogenic role of oxidative stress in hypertension might be significant.

Research Trend of Biochip Sensors for Biomarkers Specific to Diagnostics of Lung Cancer Diseases (폐암 질환 진단에 활용 가능한 바이오마커 검출용 바이오칩 센서 연구 동향)

  • Lee, Sang Hyuk;Goh, Eunseo;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.645-651
    • /
    • 2018
  • Lung cancer has the highest death rate of any cancer diseases in Koreans. However, patients often feel difficult to recognize their disease before facing the terminal diagnosis due to the absence of any significant symptoms. Furthermore, the clear detection of an early cancer stage is usually obscure with existing diagnostic methods. For this reason, extensive research efforts have been made on introducing a wide range of biochemical diagnostic tools for the molecular level analysis of biological fluids for lung cancer diagnoses. A chip-based biosensor, one type of the analytical devices, can be a great potential for the diagnosis, which can be used without any further expensive analytical equipments nor skilled analysts. In this mini review, we highlight recent research trends on searching biomarker candidates and bio-chip sensors for lung cancer diagnosis in addition to discussing their future aspects.

Development of YOLO-based apple quality sorter

  • Donggun Lee;Jooseon Oh;Youngtae Choi;Donggeon Lee;Hongjeong Lee;Sung-Bo Shim;Yushin Ha
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.3
    • /
    • pp.373-382
    • /
    • 2023
  • The task of sorting and excluding blemished apples and others that lack commercial appeal is currently performed manually by human eye sorting, which not only causes musculoskeletal disorders in workers but also requires a significant amount of time and labor. In this study, an automated apple-sorting machine was developed to prevent musculoskeletal disorders in apple production workers and to streamline the process of sorting blemished and non-marketable apples from the better quality fruit. The apple-sorting machine is composed of an arm-rest, a main body, and a height-adjustable part, and uses object detection through a machine learning technology called 'You Only Look Once (YOLO)' to sort the apples. The machine was initially trained using apple image data, RoboFlow, and Google Colab, and the resulting images were analyzed using Jetson Nano. An algorithm was developed to link the Jetson Nano outputs and the conveyor belt to classify the analyzed apple images. This apple-sorting machine can immediately sort and exclude apples with surface defects, thereby reducing the time needed to sort the fruit and, accordingly, achieving cuts in labor costs. Furthermore, the apple-sorting machine can produce uniform quality sorting with a high level of accuracy compared with the subjective judgment of manual sorting by eye. This is expected to improve the productivity of apple growing operations and increase profitability.

Stress Dependence of Thermal Stability of Nickel Silicide for Nano MOSFETs

  • Zhang, Ying-Ying;Lee, Won-Jae;Zhong, Zhun;Li, Shi-Guang;Jung, Soon-Yen;Lee, Ga-Won;Wang, Jin-Suk;Lee, Hi-Deok;Lim, Sung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.110-114
    • /
    • 2007
  • Dependence of the thermal stability of nickel silicide on the film stress of inter layer dielectric (ILD) layer has been investigated in this study and silicon nitride $(Si_3N_4)$ layer is used as an ILD layer. Nickel silicide was formed with a one-step rapid thermal process at $500^{\circ}C$ for 30 sec. $2000{\AA}$ thick $Si_3N_4$ layer was deposited using plasma enhanced chemical vapor deposition after the formation of Ni silicide and its stress was split from compressive stress to tensile stress by controlling the power of power sources. Stress level of each stress type was also split for thorough analysis. It is found that the thermal stability of nickel silicide strongly depends on the stress type as well as the stress level induced by the $Si_3N_4$ layer. In the case of high compressive stress, silicide agglomeration and its phase transformation from the low-resistivity nickel mono-silicide to the high-resistivity nickel di-silicide are retarded, and hence the thermal stability is obviously improved a lot. However, in the case of high tensile stress, the thermal stability shows the worst case among the stressed cases.

Effects of total pressure and gravity level on the physical vapor transport of $Hg_2Cl_2-Cl_2$ system

  • Choi, Jeong-Gi;Kwon, Moo-Hyun;Kim, Geug-Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.3
    • /
    • pp.116-124
    • /
    • 2009
  • Our computational studies for the physical vapor transport crystal growth of $Hg_2Cl_2-Cl_2$ system evidence suggests that the PVT growth process exhibits the diffusion-dominated behaviors for aspect ratios more than and equal to 10, which would provide purely diffusive transport conditions adequate to microgravity environments less than $10^{-3}g_0$. Also, the regimes of high temperature difference based on the fixed source temperature of $380^{\circ}C$, where ${\Delta}T$ is relatively large enough for the crystal growth of mercurous chloride, the transport rates do not keep increasing with ${\Delta}T$ but tend to some constant value of $2.12\;mole\;cm^{-2}s^{-1}$. For the aspect ratios of 5, 10, and 20, the transport rate is directly proportional to the total pressure of the system under consideration. For Ar = 5, the rate is increased by a factor of 2.3 with increasing the total pressure from 403 Torr to 935 Torr, i.e., by a factor of 2.3. For both Ar = 10 and 20, the rate is increased by a factor of 1.25 with increasing the total pressure from 403 Torr to 935 Torr.

Prototype Electromagnetic-Noise Filters Incorporated with Nano-Granular Co41Fe38Al13O8 Soft Ferromagnetic Thin Films on Coplanar Transmission Lines

  • Sohn, Jae-Cheon;Byun, Dong-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.2 s.285
    • /
    • pp.74-78
    • /
    • 2006
  • A non-integrated type noise filter on a Coplanar Waveguide (CPW) transmission line is demonstrated by using a highly resistive $Co_{41}Fe_{38}Al_{13}O_8$ nanogranular thin film with the dimensions of $4\;mm (\iota)\times4\;mm(\omega)\times0.1\;{\mu}m(t)$. The noise suppression characteristics are evaluated without placing an insulating layer between the CPW line and the magnetic thin film. The insertion loss is very low being less than 0.3 dB and this low value is maintained up to 2 GHz. At a ferromagnetic resonance frequency of 3.3 GHz, the power loss is very large and the degree of noise attenuation is measured to be 3 dB. This level of noise attenuation is still small for real applications; however, considering the small magnetic volume used in this work, further improvement is expected by simply increasing the magnetic volume and by integrating the magnetic thin film into the CPW transmission line.