• 제목/요약/키워드: Nakdong river water system

검색결과 251건 처리시간 0.03초

Subcritical Water Extraction에 의한 PCBs 추출 (Extraction of PCBs by Subcritical Water Extraction)

  • 곽동환;문지용;이성인;정기호
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.511-519
    • /
    • 2000
  • 물은 초임계 상태($T{\geq}374^{\circ}C$, $p{\geq}221$ atm)에서 비극성 유기오염물질에 대해 좋은 용매로 작용 하지만 부식성이 강하게 나타난다. Subcritical water extraction (이하 SWE)은 토양이나 저니토에 흡착되어 있는 비극성 유기오염물을 신속하고 효율적으로 추출할 수 있다. Subcritical 조건 하에 있는 물은 다양한 비극성 유기물들을 추출할 수 있다. SWE를 이용하면 토양이나 저니토로부터 수 분 이내에 PCBs를 완전히 제거할 수 있으며, 50 atm, $260^{\circ}C$의 subcritical 상태에 있는 물을 추출에 이용한다.

  • PDF

The Characteristics of Hydrogeological Parameters of Unconsolidated Sediments in the Nakdong River Delta of Busan City, Korea

  • Khakimov, Elyorbek;Chung, Sang Yong;Senapathi, Venkatramanan;Elzain, Hussam Eldin;Son, JooHyeong
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권3호
    • /
    • pp.27-41
    • /
    • 2017
  • This study dealt with the characteristics and the interrelations of hydrogeological parameters such as hydraulic conductivity, dispersivity and effective porosity of unconsolidated sediments for providing the basic data necessary for the planning of the management and preservation of groundwater quality in the Nakdong River Delta of Busan City, Korea. Groundwater quality in this area has been deteriorated due to seawater intrusion, agricultural fertilizer and pesticide, industrial wastewater, and contaminated river water. The physical properties (grain size distribution, sediment type, sorting) and aquifer parameters (hydraulic conductivity, effective porosity, longitudinal dispersivity) were determined from grain size analysis, laboratory permeability test and column tracer test. Among 36 samples, there were 18 Sand (S), 7 Gravelly Sand (gS), 5 Silty Sand (zS), 5 Muddy Sand (mS), and 1 Sandy Silt (sZ). Hydraulic conductivity was determined through a falling head test, and ranged from $9.2{\times}10^{-5}$ to $2.9{\times}10^{-2}cm/sec$ (0.08 to 25.6 m/day). From breakthrough curves, dispersivity was calculated to be 0.35~3.92 cm. Also, effective porosity and average linear velocity were obtained through the column tracer test, and their values were 0.04~0.46 and 1.06E-04~6.49E-02 cm/sec, respectively. Statistical methods were used to understand the interrelations among aquifer parameters of hydraulic conductivity, effective porosity and dispersivity. The relation between dispersivity and hydraulic conductivity or effective porosity considered the sample length, because dispersivity was affected by experimental scale. The relations between dispersivity and hydraulic conductivity or effective porosity were all in inverse proportion for all long and short samples. The reason was because dispersivity was in inverse proportion to the groundwater velocity in case of steady hydrodynamic dispersion coefficient, and groundwater velocity was in proportion to the hydraulic conductivity or effective porosity. This study also elucidated that longitudinal dispersivity was dependent on the scale of column tracer test, and all hydrogeological parameters were low to high values due to the sand quantity of sediments. It is expected that the hydrogeological parameter data of sediments will be very useful for the planning of groundwater management and preservation in the Nakdong River Delta of Busan City, Korea.

낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로 (Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir)

  • 박준상;임윤규;김규랑;조창범;장준영;강미선;김백조
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.

낙동강 제방 붕괴에 따른 범람홍수 해석 (Flood Inundation Analysis from Levee Failure in Nakdong River)

  • 전민우;한건연;최규현
    • 한국수자원학회논문집
    • /
    • 제38권4호
    • /
    • pp.259-269
    • /
    • 2005
  • 본 연구에서는 제방의 월류 및 붕괴에 따른 홍수파가 제내지로 전파되는 경우의 물리적인 특성을 고려하여 하천에 대한 홍수류 해석은 Preissmann 기법을 적용하였으며, 제내지에서의 범람해석을 위해 2차원 모형을 적용하여 해석할 수 있도록 구성하였고, 이들 두 모형이 상호 작용할 수 있는 하도-제내지 연결부 수치해석 모형을 개발하였다. 본 모형에서는 잠수효과의 해석을 위한 관련방정식을 도입하여 제내지에서의 수위 상승에 따른 하천으로부터의 월류량을 정확하게 계산할 수 있도록 구성하였다. 본 연구모형을 2002년 9월 낙동강 유역 실제 제방붕괴의 경우에 적용하여 제내지에서의 2차원 범람양상을 유속분포와 범람수심에 대해서 주요 시간대별로 계산하여 도시하였으며 모의결과는 당시의 실측자료 및 홍수범람범위와 잘 일치되는 것으로 나타났다.

하천-충적대수층계의 강변여과수를 열원으로 이용하는 지하수 열펌프 시스템의 계절별 입구온도와 효율성 평가 (Seasonal Variations of EWT and COP of GWHP System Using the Bank Infilterated Water from Stream-Alluvial Aquifer System)

  • 한찬;전재수;윤운상;한혁상;한정상
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.39-51
    • /
    • 2007
  • Unconsolidated and permeable alluvial deposit composed of sand and gravel is distributed along the fluvial plain at the Iryong study area. Previous studies on the area show that a single alluvial well can produce at least 1,650m3d-1 of bank infilterated shallow groundwater(BIGW) from the deposit. This study is aimed to evaluate and simulate the influence that seasonal variation of water levels and temperatures of the river have an effect on those of BIGW under the pumping condition and also to compare seasonal variation of COPs when indirectly pumped BIGW or directly pumped surface water are used for a water to water heat pump system as an heat source and sink using 3 D flow and heat transport model of Feflow. The result shows that the magnitude influenced to water level of BIGW by fluctuation of river water level in summer and winter is about 48% and 75% of Nakdong river water level separately. Seasonal change of river water temperature is about $23.7^{\circ}C$, on other hand that of BIGW is only $3.8^{\circ}C$. The seasonal temperatures of BIGW are ranged from minimum $14.5^{\circ}C$ in cold winter(January) and maximum $18.3^{\circ}C$ in hot summer(July). It stands for that BIGW is a good source of heat energy for heating and cooling system owing to maintaining quite similar temperature($16^{\circ}C$) of background shallow groundwater. Average COPh in winter time and COPc in summer time of BIGW and surface water are estimated about 3.95, 3.5, and about 6.16 and 4.81 respectively. It clearly indicates that coefficient of performance of heat pump system using BIGW are higher than 12.9% in winter time and 28.1% in summer time in comparision with those of surface water.

  • PDF

창원지역 낙동강 하천수와 주변 충적층을 이용한 지하수 인공함양의 효율성 평가 (Examination for Efficiency of Groundwater Artificial Recharge in Alluvial Aquifer Near Nakdong River of Changweon Area, Korea)

  • 문상호;하규철;김용철;고동찬;윤희성
    • 자원환경지질
    • /
    • 제47권6호
    • /
    • pp.611-623
    • /
    • 2014
  • 우리나라에는 4대강 주변에 충적 대수층이 많이 발달하고 있으며, 이러한 충적층을 활용한 인공함양 시스템 운영은 향후 우리나라 미래 수자원 확보에 있어서 중요한 수단이 될 수 있을 것으로 기대된다. 이 연구는 낙동강 하천변 충적층에서 대수층 저류/이동/회수 방식의 인공함양 기법을 적용하였을 때, 하천수의 반복적인 주입이 대수층의 주입능력에 어떻게 영향을 미치는가에 대하여 고찰하였다. 인공함양 시스템의 주입 효율을 평가하기 위해서 2차례에 걸친 주입시험을 실시하였으며, 각 시험에서의 주입수(하천수)와 4개 관측정 내 지하수의 혼합 비율을 계산하여 주입 효율의 변화를 검토하였다. 혼합 비율 계산에서 사용된 수질 성분은 전기전도도로서, 연구지역에서의 하천수와 대상 지하수의 EC 값은 현저한 차이를 보여 혼합 결과를 확실하게 반영해 주었다. 2차례의 주입시험 결과, 일부 관측정에서는 1차에 비해 2차 시험에서 주입 효과의 발생 시점이 매우 느리게 나타났으며, 대부분의 관측정에서 주입수의 혼합 비율 상승률이 1차 시험에 비해 2차 시험에서 현저히 저하되어 나타났다. 이러한 결과는 인공함양 시스템의 운영이 시간이 흐를수록 그 효율성이 떨어지게 됨을 지시해주는 것이며, 향후 주입수의 수처리 등 사전 관리와 함께 주기적 양수시험, 휴지기 운영 등 사후 관리가 필수적으로 수반되어야 함을 말해 준다. 하천수 주입에 의한 대수층의 수질 개선 효과는 1차 1,210분 주입 시 1일 이상, 2차 14일간 주입 시 4일 혹은 6일 이상 유지됨을 보였다.

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

1차원 수질 예측 모형의 검보정 자동화 시스템 개발 및 낙동강에서의 적용 (Development of 1-Dimensional Water Quality Model Automatizing Calibration-Correction and Application in Nakdong River)

  • 손아롱;한건연;박경옥;김병현
    • 환경영향평가
    • /
    • 제20권5호
    • /
    • pp.765-777
    • /
    • 2011
  • According to the total pollution load management system, exact prediction and analysis of water quality and discharge has been required in order to allocate the amount of pollution load to each local government. In this study, QUAL2E model was used for comparison with other water quality models and improve the inadequate to forecast future water quality. And Various calibration and verification methods were applied to deal with existing uncertainties of parameter during modeling water quality. For user convenience, A GUI(Graphical User Interface) system named "QL2-XP" model is developed by object-oriented language for the user convenience and practical usage. Suggested GUI system consist of hydraulic analysis, water quality analysis, optimized model calibration processes, and postprocessing the simulation results. Therefore this model will be effectively utilized to manage practical and efficient water quality.

결합가뭄관리지수(JDMI)를 이용한 낙동강 유역의 미래 용수공급 위험도 분석 (Future water supply risk analysis using a joint drought management index in Nakdong river basin)

  • 유지수;최시중;권현한;김태웅
    • 한국수자원학회논문집
    • /
    • 제51권spc1호
    • /
    • pp.1117-1126
    • /
    • 2018
  • 용수공급시스템은 용수를 안정적으로 확보하여 사용자의 수요량을 충족시키는 것을 목표로 하지만, 평년보다 적은 유입량으로 인해 정상공급에 실패하는 경우가 발생한다. 그러나 강수의 부족으로 발생하는 가뭄 상황이 언제나 용수공급 실패를 유발하는 것은 아니기 때문에, 용수공급에 대한 안전도를 산정할 때 실질적인 용수 부족 사상의 특성을 고려할 필요가 있다. 이를 위해 본 연구에서는 이수안전도 평가 지표로 주로 사용되는 신뢰도와 취약도를 이용하여 결합 가뭄관리지수(JDMI)를 개발하였으며, 이를 바탕으로 미래 용수공급 위험도를 산정하였다. 미래에 대한 분석을 위해 RCP 4.5 및 8.5 시나리오에 대하여 GCM으로부터 생산된 기후변화 시나리오 자료를 적용하고 미래 기간을 21세기 전기, 중기, 및 후기로 구분하였다. JDMI를 기반으로 낙동강 유역의 용수공급 위험도를 분석한 결과 RCP 4.5 시나리오에서 RCP 8.5 시나리오보다 위험도가 더 높은 것으로 분석되었다. 용수공급 취약지역은 RCP 4.5에서는 남강댐(W18)으로 나타났으며, RCP 8.5에서는 형산강(W23)과 낙동강남해(W33) 유역으로 분석되었다.

장마기의 강우가 낙동강 하류 (물금) 수질에 미치는 영향 (The Impact of monsoon Rainfall (Changma) on the Changes of Water Quality in the Lower Nakdong River (Mulgeum))

  • 박성배;이상균;장광현;정광석;주기재
    • 생태와환경
    • /
    • 제35권3호통권99호
    • /
    • pp.160-171
    • /
    • 2002
  • 본 연구는 낙동강 하류에서 장마 기간의 강우가 수질 변화에 미치는 영향을 평가하였다. 1997년 하절기 장마기간 주요 집수역의 강우상황을 분석하고 낙동강 하류역 (물금)에서 $1{\sim}3$일 간격으로 수질항목(수소이온농도, 탁도, 투명도, 엽록소-a, 용존산소, 전기전도도, 수온)과 영양염류 등(총질소, 총인, 질산성 질소, 암모니아성 질소, 인산 인, 규산)을 측정하였다. 또한 갈수기 이후 큰 강에서 최초 집중강우가 수질 변화에 미치는 영향을 평가하기 위하여 수질 자동측정장비(Hydrolab $Recorder^{TM}$)를 이용하여 장마 초기강우 전후에 1시간 간격으로 수질 및 수위변화를 모니터링하였다. 우리나라는 연간 강우의약 50%이상이 하절기 ($6{\sim}8$월)에 집중되며, 특히 장마는6월 하순경에 시작하여 7월 중순까지 약 한 달간 하천수환경에 크게 영향을 미친다. 1997년 장마기간동안 낙동강의 주요 집수역에서 50mm 이상의 강우가 내린 횟수는 총 5회였고, 여름기간 중 물금 지역에서 물리${\cdot}$화학적 환경요인에 급격한 변화가 일어난 시기는 장마 초기를 전후해서였다. 초기강우로 기초수질항목 중 수온, 수소이온농도, 전기전도도, 용존산소는 큰 폭으로 감소하였고 탁도, 영양염류 및 규산 등과 같은 항목은 증가하는 양상을 보였다. 하절기 엽록소-a 농도는 총인, 총질소의 높은 농도에도 불구하고 연중 최저치를 나타냈는데, 이는 장마 강우로 인한 탁도 증가와 수체의 체류시간감소 영향 등이 크게 작용한 것으로 사료된다. 장마 초기 강우 동안 영양염류의 농도는 크게 증가하는 양상을 보였으나 항목에 따라 그 패턴은 다소 상이했다. 장마는 몬순기후에 의해 발생하는 기상 현상으로, 연중 가장 두드러진 집중된 강우 및 급격한 유량변화를 유발함으로써 하천생태계에 큰 영향을 미치게 된다. 특히, 이 기간동안 강우의 빈도 및 강도는 하천의 육수학적 현상 변화와 패턴에 중요한 요소로서 작용하며, 이는 동아시아몬순기후대에 속하는 하천들에서 유사하게 발생하는 하천의 중요한 특성으로 사료된다.