• 제목/요약/키워드: NPC three-level

검색결과 100건 처리시간 0.027초

A Real-Time Method for the Diagnosis of Multiple Switch Faults in NPC Inverters Based on Output Currents Analysis

  • Abadi, Mohsen Bandar;Mendes, Andre M.S.;Cruz, Sergio M.A.
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1415-1425
    • /
    • 2016
  • This paper presents a new approach for fault diagnosis in three-level neutral point clamped inverters. The proposed method is based on the average values of the positive and negative parts of normalized output currents. This method is capable of detecting and locating multiple open-circuit faults in the controlled power switches of converters in half of a fundamental period of those currents. The implementation of this diagnostic approach only requires two output currents of the inverter. Therefore, no additional sensors are needed other than the ones already used by the control system of a drive based on this type of converter. Moreover, through the normalization of currents, the diagnosis is independent of the load level of the converter. The performance and effectiveness of the proposed diagnostic technique are validated by experimental results obtained under steady-state and transient conditions.

Design of 1500V solar inverter stack beyond megawatt in NPC1 topology

  • Hao, Xin;Ma, Kwok-Wai;Zhao, Jia;Sun, Xin-Yu
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.7-11
    • /
    • 2017
  • This paper describes a design concept of NPC1 power stack for 1500VDC megawatt level solar inverter. This stack uses three latest half-bridge IGBT modules with highest power density and operation junction temperature, which enable realization of power level beyond 1MW without paralleling. Critical design concept on loop inductance is explained. Dynamic characteristics are verified by double-pulse test. Thermal characteristics and output power limits are verified by thermal test. Temperature-sensitive component on PCB as output power constraint is identified. Different PCB repositioning solutions are tested to give the overall output power thermal derating curves, which enable output power of 1.15MW at $T_A=55^{\circ}C$ with $15^{\circ}C$ thermal margin. The power stack characteristic and performance change under different thermal environment is further analyzed.

  • PDF

영 전위 중성점을 가진 새로운 3상 Three-Level 스위치 전압원 인버터 (Three Phase Three-Level Switched Voltage Source PWM Inverter with Zero Neutral Point Potential)

  • 오원식;한상규;최성욱;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.630-634
    • /
    • 2004
  • A new three phase three-level Pulse Width Modulation (PWM) Switched Voltage Source (SVS) inverter with zero neutral point potential is proposed. The major advantage is that the peak value of the phase output voltage is twice as high as that of the conventional neutral-point-clamped (NPC) PWM inverter. Furthermore, three-level waveforms of the proposed inverter can be achieved without switch voltage unbalance problem. Since the average neutral point potential of the proposed inverter is zero, the common ground between input stage and output stage is possible. The proposed inverter is verified by experimental results based on a laboratory prototype.

  • PDF

자동 지령모드절환 기능을 갖춘 PMSG MV 해상 풍력 발전기의 직접전력제어 방법 (Automatic Command Mode Transition Strategy of Direct Power Control for PMSG MV Offshore Wind Turbines)

  • 권국민;서용석
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.238-248
    • /
    • 2016
  • In this study, an automatic command mode transition strategy of direct power control (DPC) is proposed for permanent magnet synchronous generators (PMSGs) medium-voltage (MV) offshore wind turbines (WTs). Benchmarking against the control methods are performed based on a three-level neutral-point-clamped (NPC) back-to-back type voltage source converter (VSC). The ramping rate criterion of complex power is utilized to select the switching vector in DPC for a three-level NPC converter. With a grid command and an MPPT mode transition strategy, the proposed control method automatically controls the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. The automatic command mode transition strategy of DPC is confirmed through PLECS simulations based on Matlab. The simulation result of the automatic mode transition strategy shows that the proposed control method of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control methods of MPPT and VOC under a step response. The proposed control method helps provide a good dynamic performance for PMSGs MV offshore WTs, thereby generating high quality output power.

A PI Control Algorithm with Zero Static Misadjustment for Tracking the Harmonic Current of Three-Level APFs

  • He, Yingjie;Liu, Jinjun;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.175-182
    • /
    • 2014
  • Tracking harmonic current quickly and precisely is one of the keys to designing active power filters (APF). In the past, the current state feedback decoupling PI control was an effective means for three-phase systems in the current control of constant voltage constant frequency inverters and high frequency PWM reversible rectifiers. This paper analyzes in detail the limitation of the conventional PI conditioner in the APF application field and presents a novel PI control method. Canceling the delay of one sampling period and the misadjustment for tracking the harmonic current is the key problem of this PI control. In this PI control, the predictive output current value is obtained by a state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by a repetitive predictor synchronously. The repetitive predictor can achieve better predictions of the harmonic current. By this means, the misadjustment of the conventional PI control for tracking the harmonic current is cancelled. The experiment results with a three-level NPC APF indicate that the steady-state accuracy and dynamic response of this method are satisfying when the proposed control scheme is implemented.

전류제어기와 전동기 모델링을 이용한 3-레벨 Neutral-Point-Clamped 인버터의 중성점 션트 저항을 통한 상전류 복원 방법 (Phase Current Reconstruction Method from Neutral Shunt Resistor in Three-Level Neutral-Point-Clamped(NPC) Inverter)

  • 유재준;구현근;김장목
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.489-490
    • /
    • 2016
  • 본 논문에서는 인버터 시스템의 가격을 줄이기 위해 3-레벨 NPC 인버터의 중성단에 하나의 션트 저항을 삽입함으로써 AC 전동기의 3상 전류를 획득하는 방법을 제안한다. 션트 저항으로부터 정확한 상 전류를 획득하기 위해서는 최소한의 시간이 필요하며 때문에 측정불가영역이 존재하게 된다. 기존의 측정불가영역으로 부터 상 전류를 복원하는 방법은 스위칭 패턴을 이동시키거나 공간 벡터 전압 변조 기법(SVPWM) 이외의 변조 기법을 이용하였는데 이러한 방법은 전류에 고조파를 증가시켜 효율을 떨어뜨리고 소음을 발생시킨다. 본 논문에서는 동기 좌표계 d-q축 비례적분제어기와 전동기 시스템의 전달함수를 이용하여 지령 전류로부터 실제 전류와 같은 전류를 얻는 방법을 통해 기존의 문제점들을 개선하는 방법을 제안한다. 제안된 방법은 시뮬레이션을 통해 증명하였다.

  • PDF

새로운 DPWM 방식을 이용한 3-레벨 인버터의 중성점 전압 리플 저감 (The DPWM Method to Reduce Neutral-Point Voltage Ripple in a Three-Level Inverter)

  • 유승종;이준석;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.315-316
    • /
    • 2015
  • 본 논문에서는 3-레벨 Neutral-Point-Clamped (NPC) 인버터의 DC-Link 중성점 전압 리플을 저감하여 인버터 출력 전압의 품질 신뢰성 향상이 가능한 새로운 Discontinuous Pulse Width Modulation (DPWM) 기법을 제안한다. NPC 인버터에서는 두 개의 커패시터로 이루어진 DC-Link 구조로 인해 상, 하단 DC-Link 커패시터 전압 불평형인 상황에서 DC-Link 중 성점 전압 리플이 발생한다. 중성점 전압 리플 발생 시 출력 전압의 품질을 보장할 수 없으며, 민감한 부하에 손상을 입힐 수 있다. 제안한 DPWM 알고리즘은 DC-Link 커패시터 전압을 조정하는 두 개의 오프셋을 사용하여 중성점 전압 리플을 저감한다. 또한, 시뮬레이션을 통해 본 논문에서 제안한 알고리즘의 타당성을 검증한다.

  • PDF

4MW급 고압 인버터 시스템 개발 (Development of 4MW Class High Voltage Inverter System)

  • 박영민;한기준;최세경;정명길;이세현
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.432-437
    • /
    • 2001
  • 본 연구는 새로이 개발된 3.3KV 4MW급의 3레벨 NPC구조의 전압형 대용량 인버터에 대한 것으로 Web 기반의 인버터 정보 관리 시스템(Inverter Information Management System)과 가상 운전 시뮬레이터가 부가된 것이다. 사용된 전동기 제어 알고리즘은 속도 센서 없이 동작 가능한 DTC(Direct Torque Control)기법으로 빠른 응답특성을 갖고 있다. IIMS는 운전상태 모니터링 및 Data 관리기능을 가지고 있으며 가상 운전시뮬레이터는 주 전원을 공급하지 않은 상태에서 시스템의 특성 검증 및 Tuning이 가능하다. 현재 이 제품은 신뢰성 검증을 위해 현장 시험 중에 있다.

  • PDF

Common-Mode Voltage Elimination with an Auxiliary Half-Bridge Circuit for Five-Level Active NPC Inverters

  • Le, Quoc Anh;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.923-932
    • /
    • 2017
  • This paper proposes a novel scheme which can compensate the common-mode voltage (CMV) for five-level active neutralpoint clamped (5L-ANPC) inverters, which is based on modifying the space vector pulse width modulation (SVPWM) and adding an auxiliary leg to the inverter. For the modified SVPWM, only the 55 voltage vectors producing low CMV values among the 125 possible voltage vectors are utilized, which varies over the three voltage levels of $-V_{dc}/12$, 0 V, and $V_{dc}/12$. In addition, the compensating voltage, which is injected into the 5L-ANPC inverter system to cancel the remaining CVM through a common-mode transformer (CMT) is generated by the additional NPC leg. By the proposed method, the CMV of the inverter is fully eliminated, while the utilization of the DC-link voltage is not decreased at all. Furthermore, all of the DC-link and flying capacitor voltages of the inverter are well controlled. Simulation and experimental results have verified the validity of the proposed scheme.

A Three Phase Three-level PWM Switched Voltage Source Inverter with Zero Neutral Point Potential

  • Oh Won-Sik;Han Sang-Kyoo;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제5권3호
    • /
    • pp.224-232
    • /
    • 2005
  • A new three phase three-level Pulse Width Modulation (PWM) Switched Voltage Source (SVS) inverter with zero neutral point potential is proposed. It consists of three single-phase inverter modules. Each module is composed of a switched voltage source and inverter switches. The major advantage is that the peak value of the phase output voltage is twice as high as that of a conventional neutral-point-clamped (NPC) PWM inverter. Thus, the proposed inverter is suitable for applications with low voltage sources such as batteries, fuel cells, or solar cells. Furthermore, three-level waveforms of the proposed inverter can be achieved without the switch voltage imbalance problem. Since the average neutral point potential of the proposed inverter is zero, a common ground between the input stage and the output stage is possible. Therefore, it can be applied to a transformer-less Power Conditioning System (PCS). The proposed inverter is verified by a PSpice simulation and experimental results based on a laboratory prototype.