• Title/Summary/Keyword: NOx removal

Search Result 242, Processing Time 0.031 seconds

Evaluation of the Removal Performance of Nitrogen Oxides of Foam Composites Using Activated Carbon and Titanium Dioxide (활성탄소와 이산화 타이타늄을 활용한 폼 복합체의 질소산화물의 제거 성능 평가)

  • Choi, Hyun-Chul;Choi, Young-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.120-127
    • /
    • 2022
  • Nitrogen oxide(NOx) is a major cause of air pollution, exists in the form of nitrogen monoxide and nitrogen dioxide, and is harmful to the human body. Recently, a number of studies to reduce NOx in the atmosphere have been conducted, and these efforts have been the same in the field of construction materials. It is known that NOx can be efficiently removed by using a photocatalytic reaction. In this study, the NOx removal performance of the foam composite using activated carbon(AC) and titanium dioxide(TiO2) was investigated. AC was used to enhance the photocatalytic reaction of TiO2 by increasing the internal specific surface area of the foam composite. In this study, foam composites were prepared using the substitution rate of AC as the main variable. The NOx removal performance of specimen was evaluated according to the test method presented in ISO-22197-1. The specific surface area of the foam composite showed a tendency to increase according to the AC content, but decreased at 15% or more. Also, when the AC substitution rate was 15%, the NOx removal efficiency was the highest.

Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향)

  • Park, Jae-Yun;Go, Hui-Seok;Son, Seong-Do;Lee, Dong-Hun;Kim, Jong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF

The Characteristic of NOx Removal Using Catalyst-Corona Discharge (촉매-코로나방전을 이용한 NOx제거 특성)

  • Goh, Hee-Suk;Park, Jae-Yoon;Kim, Jong-Suk;Lee, Soo-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.27-33
    • /
    • 2004
  • The catalytic effect of waterworks sludge on NOx removal in $BaTiO_3$pellets and sludge pellets combined packed-bed plasma reactor with plate-plate electrode geometry is measured for the various conditions. NOx removal rate is about 90[%] at $BaTiO_3$-sludge combined reactor used fresh sludge. $NO_2$ and $O_3$ as byproducts are significantly generated in only $BaTiO_3$ packed-bed plasma reactor, however, in $BaTiO_3$-sludge combined packed-bed reactor, $NO_2$ and $O_3$ are completely removed while $CO_2$ as by-products are observed from FTIR spectra. $NO_2$ and $O_3$ seem to react with metallic molecules, metal oxide, and organic compounds that are generally chlorophyll included in sludge. NOx removal rate increases with $O_2$ concentration increasing. Removal rates $NO_2$ and $O_3$ are independent of operating time and repetition measurement times.

A Study on NOx Removal by Using Plasma Discharge (플라즈마 방전을 이용한 NOx 제거에 관한 연구)

  • 김동욱;정영식
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.78-83
    • /
    • 1999
  • This work is the experimental study for NO and NOx removal by utilizing non-thermal plasma. To apply to moving pollution source such as diesel automobile, we suggested the metal packed-helical wire reactor(MPHW) and measured properties of MPHW by varying the peak voltage, frequency, NOx concentration and flow rate for simulated NOx gas balanced with $N_2$. And then we compared these results with the results of cylinder-wire(CW) which was one of popularly used reactor in nonthermal plasma applications. The results of MPHW show fairly good NO and NOx removal rate compare with CW around above 20%. However. the power consumption of MPHW is larger than that of CW as much as around 2.5Watt in all range.

  • PDF

NO Oxidation using Non-Thermal Plasma and NOx removal by NaOH-Water Solution Shower (비열플라즈마에 의한 NO의 산화와 NaOH 샤워해 의한 NOx의 제거특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Kim, Ick-Kewn;Park, Sang-Hyun;Koh, Hee-Seok;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.947-949
    • /
    • 1998
  • In this paper, the NO was oxidized $NO_2$ by using the non-thermal plasma and NOx removal characteristics were measured by showering NaOH water-solution to $NO_2$. The NO oxidation increased in the order of DC, AC, and Pulse. NOx oxidation for two stage with applied voltage was better than that for one stage with applied voltage. NO oxidation didn't depend on applied voltage. While NO oxidation was going on, NOx removal efficiency was 20-25%, however, significantly depended on the injection method of air and $H_2O$ + air. When NaOH water-solution density of 20% was showered to flue gases, NOx removal efficiency increased to 64%.

  • PDF

SO$_2$ and NOx Reaction Characteristics of Waste Clam Sorbent in Fixed Bed Reactor

  • Jung, Jong-Hyeon;Shon, Byung-Hyun;Yoo, Kyung-Sun;Kim, Hyun-Gyu;Lee, Gang-Woo;Kim, Young-Sik
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.152-156
    • /
    • 2003
  • Air pollution problems due to the emission of pollutants from the various industrial facilities become serious issues and lots of air pollution control processes have been developed. To remove the SO$_2$ and NOx emitted from the solid waste incinerator and coal fired power plants, we studied the Ca-based sorbent which was prepared by waste clam and limestone. The objectives of this study were to develop a clam-based sorbent for removal of SO$_2$ and NOx, and to investigate the physicochemical properties of the waste clam sorbent. In order to determine acid gas removal capacity of sorbent, the batch study on SO$_2$ and NOx removal was performed with the Ca-based sorbent in the fixed bed reactor. Results of the research revealed that clam-based sorbent can be used as the iron-manufacturing industry and chemical adsorbents for the removal of acid gases because the lime content of the waste calm was more than 53.92%. From physicochemical analysis and gas reaction experiments, it could be concluded that clam is good sorbent for the removal of SO$_2$ and NOx in waste incinerator and flue gas desulfurization processes.

  • PDF

Nitrogen Oxides Removal Characteristics of SNCR-SCR Hybrid System (SNCR-SCR 하이브리드 시스템의 질소산화물 제거 특성)

  • Cha, Jin Sun;Park, Sung Hoon;Jeon, Jong-Ki;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.658-663
    • /
    • 2011
  • The SNCR-SCR (selective non-catalytic reduction-selective catalytic reduction) hybrid system is an economical NOx removal system. In this study, the effect of the operating parameters of the SNCR-SCR hybrid system on NOx removal efficiency was investigated. When the SNCR reactor was operated at a temperature lower than the optimum temperature ($900{\sim}950^{\circ}C$), an additional NO removal is obtained basesd on the utilization of $NH_3$ slip. On the other hand, the SNCR reactor operated above the temperature resulted in no additional NO removal of SCR due to decomposition of $NH_3$. Therefore, the SNCR process should be operated at optimum temperature to obtain high NO removal efficiency and low $NH_3$ slip. Thus, it is important to adjust NSR (normalized stoichiometric ratio) so that $SR_{RES}$ can be maintained at an appropriate level.

Removal Characteristics of NOx Using a Soil-Biofilter (토양 Bio-Filter를 이용한 질소산화물 제거특성)

  • Cho Ki-Chul;Ko Byeung-Ik;Lee Nae-Hyun;Cho Il-Hyoung
    • Journal of Environmental Science International
    • /
    • v.15 no.2
    • /
    • pp.133-139
    • /
    • 2006
  • Soil biofiltration is an environmentally-sound technology for elimination of VOCs, odorous and NOx compounds from a low concentration, high volume waste gas streams because of its simplicity and cost-effectiveness. This study was performed to evaluate effect of removal of gaseous NOx using a soil and a yellow soil. Over $60\%\;and\;48\%$ of NOx from a soil and a yellow soil was removed at the inlet NO concentrations of $423\~451$ppb, respectively. The bio-filter using a soil media was capable of purifying NOx with a different natural processes. Although some of the processes are quite complex, they can broadly be summarized as adsorption into soil pore water, and biochemical transformations by soil bacteria. When the filteration bio-reactor was applied to a soil and a yellow soil, effective NOx removal was obtained for several times and months. These results show that a soil biofilter can be of use as an alternative advanced NOx treatment system.

A removal characteristics of NOx at the cylinderical plasma reactor with magnetic field (자계가 인가된 원통형 플라즈마 반응기에서 질소산화물의 제거특성)

  • Park, Jae-Yoon;Lee, Dong-Hoon;Koh, Yong-Sul;Park, Sang-Hyun;Koh, Hee-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1782-1784
    • /
    • 1998
  • The effect of magnetic field was measured on NOx removal for cylinderical-wire plasma reactor with magnetic field applied to electric field vertically. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power decreased NOx removal rate of plasma reactor with magnetic field were higher, 10-15%, than that of plsama reactor without magnetic field. And NOx removal rate decreased with increasing gas flow rate.

  • PDF

Synthesis of Ga-silicate and Its Catalytic Performance for NO Removal under the Presence of Water

  • Misook Kang;Yoon, Yong-Soo;Um, Myeong-Heon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.1-8
    • /
    • 1999
  • Catalytic performance for NOx removal by Ga-incorporated silicates(Ga-silicate; Gallosilicate) with MFI type synthesized by the rapid crystallization method was reported in this study. NOx removal was investigated under the condition of O2 excess(10%), with various hydrocarbons of low concentrations. Effect of H2O(2%) addition was also considered. The result showd that the conversion from NOx to N2 was enhanced on the Ga-silicate compared with the Al-silicate. Furthermore, the performance for NOx conversion on the Ga-silicate increased with addition of water.

  • PDF