Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 1998.07e
- /
- Pages.1782-1784
- /
- 1998
A removal characteristics of NOx at the cylinderical plasma reactor with magnetic field
자계가 인가된 원통형 플라즈마 반응기에서 질소산화물의 제거특성
- Park, Jae-Yoon (Dept of Electrical Engineering Kyungnam UNIV.) ;
- Lee, Dong-Hoon (VACTRON CO. LTD.) ;
- Koh, Yong-Sul (Dept of Electrical Engineering Kyungnam UNIV.) ;
- Park, Sang-Hyun (Dept of Electrical Engineering Kyungnam UNIV.) ;
- Koh, Hee-Seok (Dept of Electrical Engineering Kyungnam UNIV.)
- Published : 1998.07.20
Abstract
The effect of magnetic field was measured on NOx removal for cylinderical-wire plasma reactor with magnetic field applied to electric field vertically. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power decreased NOx removal rate of plasma reactor with magnetic field were higher, 10-15%, than that of plsama reactor without magnetic field. And NOx removal rate decreased with increasing gas flow rate.
Keywords