• Title/Summary/Keyword: NIR fluorescence

Search Result 26, Processing Time 0.021 seconds

Study on Improvement of Signal to Background Ratio of Laser-based Fluorescence Imaging System (레이저 기반 형광 영상 시스템의 Signal to Background Ratio 향상 연구)

  • Kim, J.H.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.107-111
    • /
    • 2020
  • Recently, as an aging society progresses, a lot of interest in health and diagnosis is increasing, As the field of various bio-imaging systems for guided surgery capable of accurate diagnosis has emerged as important, a Fluorescence imaging system capable of accurate measurement and real-time confirmation has emerged as an important field. Fluorescence images currently being used are mainly in the NIR-I band, but many studies are in progress in the NIR-II band in order to improve resolution and confirm fluorescence deeply and accurately. In this paper, the difference between NIR-I and NIR-II, optical characteristics, and SBR (signal to background ration) of a fluorescent imaging system, was investigated using the finite element (FEM) method. After confirming, it was confirmed that the SBR was 16.2 times higher in the NIR-II area than in the NIR-I by making the skin phantom and measuring the fluorescence. It is confirmed that the enhancement in SBR of the Fluorescence imaging system is more effective in the NIR-II region than in the NIR-I region and expected to be used in application fields such as guided surgery, bio-sensor and also device which can detect the defect of optical devices.

Real-Time Fluorescence Imaging in Thoracic Surgery

  • Das, Priyanka;Santos, Sheena;Park, G. Kate;I, Hoseok;Choi, Hak Soo
    • Journal of Chest Surgery
    • /
    • v.52 no.4
    • /
    • pp.205-220
    • /
    • 2019
  • Near-infrared (NIR) fluorescence imaging provides a safe and cost-efficient method for immediate data acquisition and visualization of tissues, with technical advantages including minimal autofluorescence, reduced photon absorption, and low scattering in tissue. In this review, we introduce recent advances in NIR fluorescence imaging systems for thoracic surgery that improve the identification of vital tissues and facilitate the resection of tumorous tissues. When coupled with appropriate NIR fluorophores, NIR fluorescence imaging may transform current intraoperative thoracic surgery methods by enhancing the precision of surgical procedures and augmenting postoperative outcomes through improvements in diagnostic accuracy and reductions in the remission rate.

NIR Fluorescence Imaging Systems with Optical Packaging Technology

  • Yang, Andrew Wootae;Cho, Sang Uk;Jeong, Myung Yung;Choi, Hak Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.25-31
    • /
    • 2014
  • Bioimaging has advanced the field of nanomedicine, drug delivery, and tissue engineering by directly visualizing the dynamic mechanism of diagnostic agents or therapeutic drugs in the body. In particular, wide-field, planar, near-infrared (NIR) fluorescence imaging has the potential to revolutionize human surgery by providing real-time image guidance to surgeons for target tissues to be resected and vital tissues to be preserved. In this review, we introduce the principles of NIR fluorescence imaging and analyze currently available NIR fluorescence imaging systems with special focus on optical source and packaging. We also introduce the evolution of the FLARE intraoperative imaging technology as an example for image-guided surgery.

Synthesis of a Novel Near-Infrared Fluorescent Dye: Applications for Fluorescence Imaging in Living Cells and Animals

  • Chen, Tongbin;Lai, Yijun;Huang, Suisheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2937-2941
    • /
    • 2013
  • Fluorescence imaging is considered as one of the most powerful techniques for monitoring biomolecule activities in living systems. Near-infrared (NIR) light is advantageous for minimum photodamage, deep tissue penetration, and minimum background autofluorescence interference. Herein, we have developed a new NIR fluorescent dye, namely, RB-1, based on the Rhodamine B scaffold. RB-1 exhibits excellent photophysical properties including large absorption extinction coefficients, high fluorescence quantum yields, and high photostability. In particular, RB-1 displays both absorption and emission in the NIR region of the "biological window" (650-900 nm) for imaging in biological samples. RB-1 shows absorption maximum at 614 nm (500-725 nm) and emission maximum at 712 nm (650-825 nm) in ethanol, which is superior to those of traditional rhodamine B in the selected spectral region. Furthermore, applications of RB-1 for fluorescence imaging in living cells and small animals were investigated using confocal fluorescence microscopy and in vivo imaging system with a high signal-to-noise ratio (SNR = 10.1).

Inorganic Nanoparticles for Near-infrared-II Fluorescence Imaging (근적외선-II 형광 이미징을 위한 무기 나노입자)

  • Park, Yong Il
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.17-27
    • /
    • 2022
  • Fluorescence imaging is widely used to image cells or small animals due to its high temporal and spatial resolution. Because conventional fluorescence imaging uses visible light, the penetration depth of light within the tissue is low, phototoxicity may occur due to visible light, and the detection sensitivity is lowered due to interference by background autofluorescence. In order to overcome this limitation, long-wavelength light should be used, and fluorescence imaging using near-infrared-I (NIR-I) in the region of 700~900 nm has been developed. To further improve imaging quality, researchers are interested in using a longer wavelength light, near-infrared-II (NIR-II) ranging from 1000 to 1700 nm. In the NIR-II region, light scattering is further minimized, and the penetration depth of light in the tissue is improved up to about 10 mm, and autofluorescence of the tissue is reduced, enabling high sensitivity and resolution fluorescence imaging. In this review, among various NIR-II fluorescence imaging probes, inorganic nanoparticle-based probes with excellent photostability and easily tunable emission wavelength were described, focusing on single-walled carbon nanotubes, quantum dots, and lanthanide nanoparticles.

Evaluation of Near-infrared Fluorescence-conjugated Peptides for Visualization of Human Epidermal Receptor 2-overexpressed Gastric Cancer

  • Jeong, Kyoungyun;Kong, Seong-Ho;Bae, Seong-Woo;Park, Cho Rong;Berlth, Felix;Shin, Jae Hwan;Lee, Yun-Sang;Youn, Hyewon;Koo, Eunhee;Suh, Yun-Suhk;Park, Do Joong;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.191-202
    • /
    • 2021
  • Purpose: A near-infrared (NIR) fluorescence imaging is a promising tool for cancer-specific image guided surgery. Human epidermal receptor 2 (HER2) is one of the candidate markers for gastric cancer. In this study, we aimed to synthesize HER2-specific NIR fluorescence probes and evaluate their applicability in cancer-specific image-guided surgeries using an animal model. Materials and Methods: An NIR dye emitting light at 800 nm (IRDye800CW; Li-COR) was conjugated to trastuzumab and an HER2-specific affibody using a click mechanism. HER2 affinity was assessed using surface plasmon resonance. Gastric cancer cell lines (NCI-N87 and SNU-601) were subcutaneously implanted into female BALB/c nu (6-8 weeks old) mice. After intravenous injection of the probes, biodistribution and fluorescence signal intensity were measured using Lumina II (Perkin Elmer) and a laparoscopic NIR camera (InTheSmart). Results: Trastuzumab-IRDye800CW exhibited high affinity for HER2 (KD=2.093(3) pM). Fluorescence signals in the liver and spleen were the highest at 24 hours post injection, while the signal in HER2-positive tumor cells increased until 72 hours, as assessed using the Lumina II system. The signal corresponding to the tumor was visually identified and clearly differentiated from the liver after 72 hours using a laparoscopic NIR camera. Affibody-IRDye800CW also exhibited high affinity for HER2 (KD=4.71 nM); however, the signal was not identified in the tumor, probably owing to rapid renal clearance. Conclusions: Trastuzumab-IRDye800CW may be used as a potential NIR probe that can be injected 2-3 days before surgery to obtain high HER2-specific signal and contrast. Affibody-based NIR probes may require modifications to enhance mobilization to the tumor site.

In vivo Dendritic Cell Migration Tracking Using Near-infrared (NIR) Imaging (Near-infrared (NIR) 영상기법을 이용한 생체 내 수지상세포의 이동)

  • Lee, Jun-Ho;Jung, Nam-Chul;Lee, Eun Gae;Lim, Dae-Seog
    • KSBB Journal
    • /
    • v.27 no.5
    • /
    • pp.295-300
    • /
    • 2012
  • Matured dendritic cells (DCs) begin migration with their release from the bone marrow (BM) into the blood and subsequent traffic into peripheral lymphoid and non-lymphoid tissues. Throughout this long movement, migrating DCs must apply specialized skills to reach their target destination. Non-invasive in vivo cell-tracking techniques are necessary to advance immune cell-based therapies. In this study, we used a DiD cell-tracking solution for in vivo dendritic cell tracking in naive mice. We tracked DiD (non-invasive fluorescence dye)-labeled mature dendritic cells using the Near Infrared (NIR) imaging system in normal mice. We examined the immunophenotype of DiD-labeled cells compared with non-labelled mature DCs, and obtained time-serial images of NIR-DC trafficking after mouse footpad injection. In conclusion, we confirmed that DiD-labeled DCs migrated into the popliteal lymph node 24 h after the footpad injection. Here, these data suggested that the cell tracking system with the stable fluorescence dye DiD was useful as a cell tracking tool to advance dendritic cell-based immunotherapy.

Analysis for Concentration Range of Fluorescein Sodium (플루오레신나트륨의 농도 범위 분석)

  • Lee, Da-Ae;Kim, Yong-Jae;Yoon, Ki-Cheol;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

Development of Small System for Mobile-Based Visible/NIR Animal Imaging (실험동물용 가시광선/근적외선 생체 이미징 소형 장비의 개발)

  • Eum, Nyeon-Sik;Park, Hee-Joon;Jung, Jin-Yong;Han, Jung-Hyun;Kim, Hyung-Kyung;Jang, Eun-Yoon;Lee, Suck-Jae;Kang, Byoung-Ho;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.270-275
    • /
    • 2012
  • In this study, we have developed a mobile-based visible/NIR(Near InfraRed) imaging equipment for the animal testing. This equipment can provide visible, NIR and merged image through the viewer program. Especially, merged image help researcher to understand visual messages at animal in-vivo test. Also, it is available to send real-time images through the smart phone. Researcher can communicate with another researcher who is a long distance away. Also, the equipment was made with portable small size to enable it to commercialize.

Short-Wave Infrared Fluorescence-Guided Surgery Using Indocyanine Green in a Dog with a Cutaneous Mast Cell Tumor

  • Su-Hyeon Kim;Sungin Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.395-399
    • /
    • 2022
  • A 6-year-old spayed, female golden retriever dog was presented with a skin mass on the dorsal region of the right carpus. The cytology result of the region revealed characteristics of mast cell tumors (MCTs). Short wave-infrared fluorescence-guided surgery using Indocyanine green (ICG) was performed to determine the surgical margin of the tumor. ICG was injected intravenously 24 hours before the surgery and the patient was hospitalized and carefully monitored. During the surgery, ICG fluorescence-based surgery was performed to identify the tumor and the surgical margin. The tumor was visible, and the skin mass was resected using NIR device for the guidance of the surgical margin of the tumor. Once the resection was complete, the surgical site was again inspected with SWIR fluorescence imaging to identify residual tumor cells. The resected tumor, using ICG navigation, was classified as low-grade cutaneous MCT and the margin was complete on the histopathological result. We report herein a case of resection of a cutaneous MCT in a dog using SWIR fluorescence imaging ICG which can be potentially used for the identification of tumors and evaluation of the surgical margin for complete resection.