• 제목/요약/키워드: N.D.C method

검색결과 792건 처리시간 0.029초

$Ca_{2-X}-Ln_{x}MnO_{4}$상의 합성과 결정구조 정밀화 {Ln=Gd, Nd, Pr, Sm} (Syntheses and structure refinement of $Ln_{x}MnO_{4}$ {Ln=Gd, Nd, Pr, Sm})

  • 서상일;이재열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.726-729
    • /
    • 2000
  • Though L $a_{1+x}$S $r_{2-x}$M $n_2$ $O_{7}$ n=2 R-P phases have been well known to have CMR effect, it was generally believed that n=1 phase was insulating. But recently monolayered perovskite $Ca_{2-x}$L $n_{x}$Mn $O_4$phase has been reported to show magnetoresistance. In this study, layered perovskite $Ca_{2-x}$L $n_{x}$Mn $O_4$ (x=0, 0.5, Ln=Pr, Nd, Sm, Gd) phases were synthesized by solid state reaction and their structures were refined by Rietveld method. The space groups of $Ca_2$Mn $O_4$, N $d_{0.5}$C $a_{1.5}$Mn $O_4$phases were refined as C2cb and Fmmm, respectively.y.ely.y.y.y.y.y.y.

  • PDF

Chain Length Effect on the Configurational Properties of an n-Alkane Chain in Solution

  • Jeon, Seung-Ho;Ree, Tai-Kyue;Oh, In-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권5호
    • /
    • pp.367-371
    • /
    • 1986
  • Dynamic and equilibrium properties of n-alkane chains immersed in solvent molecules have been investigated by a molecular dynamics method. The n-alkane chain is assumed to be a chain of elements (CH$_2$) interconnected by bonds having a fixed bond length and bond angle, but each bond of the chain is allowed to execute hindered internal rotation. We studied the effect of the number of the chain elements (N$_c$ = 10, 15 and 20) on the equilibrium properties of the system, e.g., the pair correlation functions between a chain element and solvent molecules, g$_{cs}$(r), and between the chain elements, g$_{cc}$(r), and the configurational properties such as the mean-square end-to-end distance < R$^2$ >, the mean-square radius of gyration < S$^2$ >, and the eigenvalues of the moment-of-inertia tensor < S$_i^2$ > / < S$^2$ > (i = 1, 2 and 3). We also studied the dynamic properties of the system, e.g., the autocorrelation function C(A;t) where A = R$^2$(t), = S$^2$(t), or = ${\vec{V}}(t)({\vec{V}}$ = velocity of the center of mass), and the diffusion coefficient D. The g$_{cs}$(r)'s are almost equal irrespective of the change of Nc while g$_{cc}$(r) becomes larger as N$_c$ increases; The MD computed configurational properties < R$^2$2 > and < S$^2$ > were found to be a little different from the values calculated from the statistical equations of < R$^2$ > and < S$^2$ >, it may be due to the fact that our model for the MD simulations includes a long-range volume effect. From the < S$_i^2$ > / < S$^2$ >, it is found that the chain molecule has a nearly spherical shape irrespective of the variation of N$_c$. For the dynamic properties we found that the C(R$^2$;t) and C(S$^2$;t) of lower N$_c$ decay faster than those of higher N$_c$, while the C($\vec V$;t) of the center of mass in the chain is weakly dependent on the N$_c$. The center of mass diffusion coefficient D$_c$ decreases as N$_c$ increases while the end point diffusion coefficient D$_e$ is nearly equal irrespective of the change of N$_c$.

압전박막의 특성평가 및 표준화 (Characterization and Standardization of Piezoelectric Thin Films)

  • 김동국;지정범
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1054-1059
    • /
    • 2002
  • A great deal of research has been done in the field of characterization for piezoelectric thin films after the first report on the measurement for the piezoelectric coefficient of thin films in 1990. The main idea of this research is to provide a distinctive solution for the measurement and standardization of both the longitudinal and the transverse piezoelectric d-coefficients, d33 and d31, of ferroelectric thin films. In general, to get these two coefficients of thin films, two different measuring systems are required. Here, we propose the improved method for the evaluation of these two coefficients with single equipment and with the relatively convenient procedure. The two-step loading process of applying the both positive and the negative pressure has been introduced to acquire the piezoelectric coefficients. These results have been calibrated for both the longitudinal and 4he transverse piezoelectric d-coefficients, d33 and 431, of thin films by comparison with the virtual standard created from FEM. In this experiments, we have obtained d33 of 331pC/N and 031 of -92.2pC/N for the PZT thin films.

TiN 코팅된 지대주 나사의 반복 착탈 후 표면 변화와 적합도에 관한 연구 (SURFACE CHANGE AND FIT OF TIN-COATED ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING)

  • 김종남;정재헌;김희중
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.119-130
    • /
    • 2007
  • Statement of problem: A few dry lubricants were applied to abutment screws for the improvement of joint stability. Purpose: The purpose of this study was to evaluate the surface change and fit of TiN-Coated abutment screw through the examination of tested screws in the field emission scanning electron microscope(FE-SEM;Netherland, Phillips co., model:XL 30 SFEG) after repeated closing and opening. Materials and method: Titanium(3i/implant Innovations Inc, USA) and Gold-Tite abutment screws(3i/implant Innovations Inc, USA) were selected for Group A and C respectively. TiN coated titanium abutment screws were also divided into two groups, Group B and D. Abutment screws of each group and the fit of abutment screw/implant fixture/abutment were observed on FE-SEM after repeated closing and opening test respectively. Results: 1. The abutment screws of TiN coated groups(Group B and D) showed more remarkable wear resistance in the threads of the screw than those of the other group(Group A and C). 2. There were more severe wear and defect of TiN coating in Group D tightened to 32 Ncm than Group B to 20 Ncm. 3. There was no difference in the fit of abutment screw/fixture/abutment among four groups, Group A, Group B, Group C and Group D. Conclusion: Under the conditions of this study, it is suggested that TiN coating of abutment screw be clinically acceptable and be expected to reduce the risk of abutment screw loosening. TiN coating of abutment screw showed good resistance against wear and the adequate fit of abutment screw/implant fixture/abutment.

A New Chemiluminescence Method for Determination of Cytosine Arabinoside in Pharmaceutical Preparations

  • Cai, Z.;Zhang, X.;Lu, D.F.;Gan, J.N.
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.171-176
    • /
    • 2012
  • A novel chemiluminescence (CL) system was established for the determination of cytosine arabinoside (Ara-C) in pharmaceutical preparations. It was showed that a clear CL signal was observed when Eosin Y mixed with Fenton reagent. The CL intensity was decreased significantly when Ara-C was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with the Ara-C concentration. Based on this, we developed a new method for the determination of Ara-C using a flow injection analysis (FIA) technique with CL detection. Under the optimal conditions, the linear range of Ara-C concentration was $6.0{\times}10^{-9}\sim1.0{\times}10^{-7}mol/L$ (R = 0.9982) with a detection limit of $7.6{\times}10^{-10}mol/L$ (S/N=3), the RSD was 5.6% for $6.0{\times}10^{-8}mol/L$ Ara-C (n = 11). The method was successfully applied to the determination of Ara-C in injection samples. The possible chemiluminescence reaction mechanism was discussed.

$C_{16}H_{19}O_2N_3CuCl_2\;{\cdot}\;H_2O$의 결정 구조 ([ $C_{16}H_{19}O_2N_3CuCl_2\;{\cdot}\;H_2O$ ])

  • 김문집;김영수;최기영
    • 한국결정학회지
    • /
    • 제15권2호
    • /
    • pp.99-103
    • /
    • 2004
  • X-선 회절법을 이용하여 $C_{16}H_{19}O_2N_3CuCl_2\;{\cdot}\;H_2O$의 분자 및 결정구조를 해석하였다. 이 결정의 결정계는 Triclinic이고 공간군은 Pl이며, 단위포 상수는 $a=7.6202(9)\;{\AA},\;b=8.5943(7){\AA},\;c= 8.6272(6){\AA},\;\alpha=67.518(6)^{\circ},\; \beta= 68.043(8)^{\circ},\;\gamma=74.370(8)^{\circ},\;V=478.89(8)\;{\AA}^3,\;T=295K,\; Z=1,\;D_c=1.504Mgm^{-3}$이다. 회절반점들의 세기는 Enraf-Nonius CAD-4 Diffractometer로 얻었으며 graphite로. 단색화한 $MoK{\alpha}$,$(\alpha=0.7107\;\AA)$을 사용하였다. 분자구조는 Direct method로 풀었으며, $F_0>4\sigma(F_0)$인 1659개의 독립회절데이터에 대하여 최소 자승법으로 234개의 변수를 정밀화하여 최종 신뢰도 값 $R=2.47\%$를 얻었다.

팔체질 진단을 위한 단계별 설문지 개발 연구 (A Study on Stage Classification of Eight Constitution Questionnaire)

  • 이주호;김민용;김희주;신용섭;오환섭;박영배;박영재
    • 대한한의진단학회지
    • /
    • 제16권2호
    • /
    • pp.59-70
    • /
    • 2012
  • Objectives : Pulse diagnosis by Expert is the only way to classify 8 Constitutions so the study to supplement classifying method by the questionnaire has developed and modified and ECM-32 System has designed in 2010. But analyzing with Decision tree had many nodes and 32 important questions omitted while processing the data. So this study was to classify the 8 constitution patients into 2 groups first and analyze its characters in consecutive order. Methods : The participants of this study were 1027 patients who classified into one of the 8 constitutions according to pulse diagnosis and answered 251 questionnaires in 2010. They were divided into sympathetic nerve acceleration constitution and parasympathetic nerve acceleration constitution and analyzed with decision tree. Results : The reponses of the questionnaire were analyzed with 4 methods of 5 scales interval method from 0 to 5, Na, Low(1,2), Medium(3), High(4,5), average value, Y/N dichotomy. Average Value had no significance. 1. From the 5 scale interval method 6 questionnaires with 7 nodes (F5e, B1d, F7f, F2a, F1b, C4L) were significant. The accuracy was 92.5%. 2. From L, M, H method 7 questionnaires with 7 nodes(F5e, B1d, F7f, F1a, B1c, C4L, P3d) were significant. The accuracy was 92.5%. 3. From Y/N dichotomy 9 questionnaires with 9 nodes( F5e, B1d, F7f, F1a, B1c, C4L, B1b, P1i, B2a) were significant. The accuracy was 93.18%. Conclusions : Based on this study, Yes or No dichotomy method was most significant and categorized among the 4 methods. Unlike previous studies which used interval scale method only, Y/N dichotomy method was more statistically significant with the questionnaire to supplement the method of pulse diagnosis. For further study by analyzing decision tree method in consecutive order, the patients can be divided into 8 Constitutions with higher significance with less questionnaires.

Equilibrium Geometries of the Neutral and Ionic Clusters of $Ag_7$, $Ag_8$, and $Ag_9$ Studied by Intermediate Neglect of Differential Overlap Method

  • 유창현;선호성
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권10호
    • /
    • pp.953-954
    • /
    • 2000
  • The equilibrium geometrical structures of silver atom clusters at their electronic ground states have been theo-retically determined by using the nonrelativistic semiempirical INDO/1 method. The clusters investigated are Agn, Agn+, and Agn- (n = 7 , 8, 9). In order to find the most stable structure, i.e., the global minimum in energy hypersurface, geometry optimization and energy calculation processes have been repeatedly performed for all the possible graphical models by changing the bond parameters (resonance integral values). The heptamers are pentagonal bipyramidal-Ag7(D5h), Ag7+ (D5h), Ag7- (D5h); the octamers are pentagonal bipyramidal with one atom capped-Ag8(D2d), Ag8+ (Cs), Ag8- (D2d); the nonamers are pentagonal bipyramidal with two atoms capped -Ag9(C2v), Ag9+ (C2v), Ag9- (C2v). Our structures are in good agreement with those by ab initio calculations ex-cept for the anionic Ag9- cluster. And it is noted that the INDO/1 method can accurately predict the Ag cluster geometries when a proper set of bond parameters is used.

진공 증착 중합법에 의해 제작된 폴리이미드박막의 유전특성 (The capacitance characteristics of polyimide thin films by VDP Method)

  • 김형권;김종석;김두석;박복기;김득연;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1171-1173
    • /
    • 1995
  • Polyimide thin films were fabricated through the vapor deposition polymerization method, and the structure and capacitance characteristics of them were investigated in detail. It was found that the chemical structure and uniformity of the film could be stabilized with curing. The peaks of $720cm^{-l},\;1380cm^{-1}\;and\;1780cm^{-1}$ show C=O stretch mode, C-N stretch mode and carbonyl stretch mode, and those of polyimide which cured over $300^{\circ}C$ were fixed. It was found that capacitance was changed in proportion to temperature.

  • PDF

연약지반에 있어 N치에 의한 기초공법 대책연구 (On the Counter Plan of Foundation Method being based on N-Value in the Soft-Ground)

  • 이용희;이대명
    • 한국항만학회지
    • /
    • 제10권2호
    • /
    • pp.69-90
    • /
    • 1996
  • This study is related to save the bearing capacity from using Meyerhof formula namely, static mechanics formula with the S.P.T(N value) of the soft ground and is to choose the soft ground improvement method by the using of total load for the proper method of the pile foundation and then to design the most suitable pile foundation to fit the actual circumstance. The purpose of this study is calculating the diameter of the pile foundation by static mechanics formula and introducing the optimum design condition from the result of the bearing capacity for using N value of the S.P.T obtained from the deep soft ground about the piles such as P.H.C pile, pipe and cast-in-place pile of big diameter, etc. As above-mentioned, it is considered that the use of P.H.C pile or pipe pile is advisable on the synthetical investigation and that the selection of cast-in-place pile method is desirable in terms of the constructive safety and durability.

  • PDF