• Title/Summary/Keyword: N-continuous

Search Result 1,728, Processing Time 0.035 seconds

CHARACTERIZATIONS OF GAMMA DISTRIBUTION

  • Lee, Min-Young;Lim, Eun-Hyuk
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.20 no.4
    • /
    • pp.411-418
    • /
    • 2007
  • Let $X_1$, ${\cdots}$, $X_n$ be nondegenerate and positive independent identically distributed(i.i.d.) random variables with common absolutely continuous distribution function F(x) and $E(X^2)$ < ${\infty}$. The random variables $X_1+{\cdots}+X_n$ and $\frac{X_1+{\cdots}+X_m}{X_1+{\cdots}+X_n}$are independent for 1 $1{\leq}$ m < n if and only if $X_1$, ${\cdots}$, $X_n$ have gamma distribution.

  • PDF

Is Initial Loading Dose Necessary for Continuous Epidural Analgesia after Brief Surgery? (단시간 수술 후 지속적 경막외 통증 조절에서도 부하용량은 필요한가?)

  • Cha, Young-Deog;Song, Jang-Ho;Song, Jung-Hun;Kim, Tae-Jung;Lee, Hong-Sik;Lee, Choon-Soo;Lee, Sung-Keun;Park, Dong-Ho
    • The Korean Journal of Pain
    • /
    • v.13 no.1
    • /
    • pp.44-48
    • /
    • 2000
  • Background: The continuous epidural analgesia is a popular method in the management of postoperative pain. However, the exact regimen for the optimal analgesia is still in dispute. In this study, we evaluated the effect of an initial loading dose prior to the continuous epidural infusion after a brief surgery, which may have some residual effects of local anesthetics that is used for the intraoperative epidural anesthesia. Methods: Seventy five patients required epidural anesthesia with 15 ml of 2% mepivacaine for the perianal surgery were randomly divided into three groups: Group 1, being the control group (n=25) did not received postoperative epidural pain control. But, group 2 (n=25) and 3 (n=25) received continuous epidural analgesia with local anesthetics and morphine immediately after surgery. In Group 2, the patients received continuous epidural infusion without initial loading dose. In Group 3, the patients received initial loading dose (1% mepivacaine 6 ml and morphine 1 mg) and followed by continuous epidural infusion. We evaluated the number of patients who needed adjuvant analgesics, the pain score, and incidence of side effects for the postoperative 48 hours. Results: At postoperative 12 hours, in group 3, the two variables, the number of patients who needed analgesics and the pain score showed a statistical significance with low scores compared with group 1 and 2. At postoperative 24 and 48 hours, the two variables indicated above did not show any differences in group 2 and 3. The incidence of side effects is not different among the three groups. Conclusions: The loading dose prior to continuous epidural infusion is necessary after a brief surgery which may have some residual effects of local anesthetics that is used for the intraoperative epidural anesthesia.

  • PDF

A Study on the Korean Broadcasting Speech Recognition (한국어 방송 음성 인식에 관한 연구)

  • 김석동;송도선;이행세
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.53-60
    • /
    • 1999
  • This paper is a study on the korean broadcasting speech recognition. Here we present the methods for the large vocabuary continuous speech recognition. Our main concerns are the language modeling and the search algorithm. The used acoustic model is the uni-phone semi-continuous hidden markov model and the used linguistic model is the N-gram model. The search algorithm consist of three phases in order to utilize all available acoustic and linguistic information. First, we use the forward Viterbi beam search to find word end frames and to estimate related scores. Second, we use the backword Viterbi beam search to find word begin frames and to estimate related scores. Finally, we use A/sup */ search to combine the above two results with the N-grams language model and to get recognition results. Using these methods maximum 96.0% word recognition rate and 99.2% syllable recognition rate are achieved for the speaker-independent continuous speech recognition problem with about 12,000 vocabulary size.

  • PDF

Immediate Effect of Intermittent Versus Continuous Hamstring Static Stretching on the Muscle Tone and Range of Motion

  • Chen, Jin-Gyi;Choi, Eun-Hong;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.4
    • /
    • pp.19-27
    • /
    • 2019
  • PURPOSE: This study examined which stretching exercise had the most positive effect on increasing the range of motion (ROM) of the knee joint in healthy people and whether there was a difference between continuous stretching and intermittent stretching. METHODS: This study included 30 healthy university students from OOO University. The subjects were asked to sit on a mat and perform hamstring-stretching exercise during which the ROM and muscle tone were measured with pre and post-tests. Each subject was assigned randomly to a continuous stretching group (stretching without relaxation time group, n=10, G1) or intermittent stretching group (stretching with 10s relaxing time group, n=10, G2; and stretching with 20s relaxing time group, n=10, G3). The participants conducted hamstring stretching exercises with a sit-and-reach box at three different rest times (0s, 10s, and 20s). Subsequently, they underwent passive knee extension (PKE) tests, in which the ROM of the knee joint was measured with a goniometer, and the muscle tone was evaluated using a MyotonPro. RESULTS: Significant differences in muscle tone, stiffness, and ROM were observed between pre-test and post-test in each groups (p<.05). Although the post hoc tests indicated no significant differences in muscle tone and ROM between the continuous stretching group and intermittent stretching group (p>.05), the rate of change of the ROM showed that the intermittent stretching group developed more effective maintenance of the hamstring flexibility. CONCLUSION: No significant differences in the muscle tone of the hamstring and ROM of the knee joint were observed according to the hamstring stretching exercises with three different rest times. On the other hand, the rate of change of the ROM showed that intermittent stretching maintained the hamstring flexibility more effectively.

PRODUCT PROPERTIES OF DIGITAL COVERING MAPS

  • HAN SANG EON
    • Journal of applied mathematics & informatics
    • /
    • v.17 no.1_2_3
    • /
    • pp.537-545
    • /
    • 2005
  • The aim of this paper is to solve the open problem on product properties of digital covering maps raised from [5]. Namely, let us consider the digital images $X_1 {\subset}Z^{n_{0}}$ with $k_0-adjacency$, $Y_1{\subset}Z^{n_{1}}$ with $k_3-adjacency$, $X_2{\subset}Z^{n_{2}}$ with $k_2-adjacency$ and $Y_2{\subset}Z^{n_{3}}$ with $k_3-adjacency$. Then the reasonable $k_4-adjacency$ of the product image $X_1{\times}X_2$ is determined by the $k_0-$ and $k_2-adjacency$ and the suitable k_5-adjacency$ is assumed on $Y_1{\times}Y_2$ via the $k_1-$ and $k_3-adjacency$ [3] such that each of the projection maps is a digitally continuous map, e.g., $p_1\;:\;X_1{\times}X_2{\rightarrow}X_1$ is a digitally ($k_4,\;k_1$)-continuous map and so on. Let us assume $h_1\;:\;X_1{\rightarrow}Y_1$ to be a digital $(k_0, k_1)$-covering map and $h_2\;:\;X_2{\rightarrow}Y_2$ to be a digital $(k_2,\;k_3)$-covering map. Then we show that the product map $h_1{\times}h_2\;:\;X_1{\times}X_2{\rightarrow}Y_1{\times}Y_2$ need not be a digital $(k_4,k_5)$-covering map.

Effects of process parameters on kerfwidth and characteristics of the cut surface for the case of cutting of CSP 1N sheet using high power continuous wave Nd:YAG laser (고출력 연속파형 Nd:YAG 레이저를 이용한 CSP 1N 박판재 절단시 공정변수가 절단폭 및 절단표면특성에 미치는 영향)

  • Ahn D.G.;Kim M.S.;Lee S.H.;Yoo Y.T.;Park H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.418-421
    • /
    • 2005
  • The objective of this research work is to investigate the effects of process parameters, such as power of laser, travel speed of laser and material thickness, on kerfwidth and characteristics of the cut surface for the case of cutting of CSP 1N sheet using high power continuous wave Nd:YAG laser. In order to find relationship between the process parameters on the quality of the cut section, such as kerfwidth, surface roughness and the striation formation, several laser cutting experiments are carried out. From the results of experiments, an optimal cutting speed for each cutting condition has been obtained to improve the quality of the cut surface.

  • PDF

Synchronization Method for Continuous Play among Multimedia Devices (다중 기기에서 이어 보기를 위한 동기화 기법)

  • Kang, Mi-Ran;Kim, Se-Young;Kim, Young-Il;Kim, Dae-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.543-551
    • /
    • 2011
  • Recently various handheld multimedia devices are spreading, and users want to share media contents across their own multiple devices. Conventional synchronization techniques for N-screen services can continuously play contents by switching from an initial device to a new device. In this case, even if a new device plays continuously contents, the initial device stops playing them. In this paper, we propose a synchronization technique in which multiple devices can share and continuously play same contents simultaneously by gathering and passing URI and current play-time of the contents. The proposed synchronization technique is built on UPnP and DLNA, and tested by implementing a wireless home media network system.

A NOTE ON RECURSIVE SETS FOR MAPS OF THE CIRCLE

  • Cho, Seong Hoon
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.13 no.1
    • /
    • pp.101-107
    • /
    • 2000
  • For a continuous map f of the circle to itself, we show that if P(f) is closed, then ${\Gamma}(f)$ is closed, and ${\Omega}(f)={\Omega}(f^n)$ for all n > 0.

  • PDF