• Title/Summary/Keyword: N defect

Search Result 635, Processing Time 0.027 seconds

Comparison of the effects of horizontal and vertical micro-osteoperforations on the biological response and tooth movement in rabbits

  • Kim, Seok-gon;Kook, Yoon-Ah;Lim, Hee Jin;Park, Patrick;Lee, Won;Park, Jae Hyun;Bayome, Mohamed;Kim, Yoonji
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.304-312
    • /
    • 2021
  • Objective: This study aimed to compare the amount of tooth movement after multiple horizontal (MH) and single vertical (SV) micro-osteoperforations (MOPs), and evaluate the histological changes after orthodontic force application in rabbits. Methods: The mandibles of 24 white rabbits were subjected to two experimental interventions: MH and SV MOPs. Defect volume of the MOPs between the two groups was kept similar. A force of 100 cN was applied via a coil spring between the incisor teeth and the first premolars. The amount of tooth movement was measured. Differences in the amount of tooth movement and bone variables at three time points and between the two groups were evaluated using repeated-measures analysis of variance. Results: The first premolar showed a mesial movement of 1.47 mm in the MH group and 1.84 mm in the SV group, which was significantly different at Week 3 (p < 0.05). No significant difference was observed in bone volume and bone fraction between the groups. Tartrate-resistant acidic phosphatase-positive cell count was also significantly greater at Week 3 than at Week 1 in both the SV and MH groups. Conclusions: The amount of tooth movement showed significant differences between Weeks 1 and 3 in the SV and MH MOP groups, but showed no differences between the two groups. Therefore, SV MOP could be considered an effective tool for enhancing tooth movement, especially for molar distalization, uprighting, and protraction to an edentulous area.

Outcomes of Coronary Artery Bypass Grafting after Extracorporeal Life Support in Patients with Cardiac Arrest or Cardiogenic Shock

  • Kim, Younghwan;Cho, Yang-Hyun;Yang, Ji-Hyuk;Sung, Kiick;Lee, Young Tak;Kim, Wook Sung;Lee, Heemoon;Cho, Su Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.70-77
    • /
    • 2019
  • Background: Extracorporeal life support (ECLS) is used as a bridge to revascularization in high-risk patients with ischemic heart disease. We reviewed our experiences of coronary artery bypass grafting (CABG) after ECLS in patients with cardiac arrest or refractory cardiogenic shock. Methods: We retrospectively reviewed 4,616 patients who underwent CABG at our institution between May 2006 and February 2017. We identified patients who underwent CABG following ECLS for cardiogenic shock or cardiac arrest. Twenty-three patients (0.5% of all CABG cases) were enrolled in the analysis. Their median age was 65 years (Q1-Q3, 58-77 years). Nine patients (39.1%) were diagnosed with ST-elevation myocardial infarction. Mechanical complications after acute myocardial infarction, including acute mitral regurgitation, left ventricular rupture, and ventricular septal defect, occurred in 9 patients (39.1%). Results: The median time from cardiopulmonary resuscitation to ECLS initiation was 25 minutes (Q1-Q3, 18.5-28.5 minutes). Conventional CABG was performed in 10 patients (43.5%) who underwent concomitant intracardiac procedures. Postoperative ECLS was required in 16 patients (69.5%). The rate of successful ECLS weaning was 91.3% (n=21). There were 6 early mortalities (26.1%). Conclusion: CABG after ECLS was very rare in real-world circumstances. Although the early mortality rate was high, the risk of mortality may be acceptable under such devastating circumstances.

Electrical Conductivity of the Solid Solutions X $ZrO_2+ (1-X) Yb_2O_3; 0.01{\leq}X{\leq}0.09$

  • Choi Byoung Ki;Jang Joon Ho;Kim, Seong Han;Kim, Hong Seok;Park, Jong Sik;Kim Yoo Young;Kim, Don;Lee Sung Han;Yo Chul Hyun;Kim Keu Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.3
    • /
    • pp.248-252
    • /
    • 1992
  • $ZrO_2-dopedYb_2O_3solid$ solutions containing 1, 3, 5, 7 and 9 mol% $ZrO_2were$ synthesized from spectroscopically pure $Yb_2O_3$ and $ZrO_2$ powders and found to be rare earth C-type structure by XRD technique. Electrical conductivities were measured as a function of temperatures from 700 to $1050^{\circ}C$ and oxygen partial pressures from 1${\times}$$10^-5$ to 2${\times}$ $10^-1$atm. The electrical conductivities depend simply on temperature and the activation energies are determined to be 1.56-1.68 $_eV$. The oxygen partial pressure dependence of the electrical conductivity shows that the conductivity increases with increasing oxygen partial pressure, indicating p-type semiconductor. The $PO_2$ dependence of the system is nearly power of 1/4. It is suggested from the linearity of the temperature dependence of electrical conductivity and only one value of 1/n that the solid solutions of the system have single conduction mechanism. From these results, it is concluded that the main defects of the system are negatively doubly charged oxygen interstitial in low. $ZrO_2doping$ level and negatively triply charged cation vacancy in high doping level and the electrical conduction is due to the electronic hole formed by the defect structure.

Optical Properties of Silicon Oxide (SiOx, x<2) Thin Films Deposited by PECVD Technique (PECVD 방법으로 증착한 SiOx(x<2) 박막의 광학적 특성 규명)

  • Kim, Youngill;Park, Byoung Youl;Kim, Eunkyeom;Han, Munsup;Sok, Junghyun;Park, Kyoungwan
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.9
    • /
    • pp.732-738
    • /
    • 2011
  • Silicon oxide thin films were deposited by using a plasma-enhanced chemical-vapor deposition technique to investigate the light emission properties. The photoluminescence characteristics were divided into two categories along the relative ratio of the flow rates of $SiH_4$ and $N_2O$ source gases, which show light emission in the broad/visible range and a light emission peak at 380 nm. We attribute the broad/visible light emission and the light emission peak to the quantum confinement effect of nanocrystalline silicon and the Si=O defects, respectively. Changes in the photoluminescence spectra were observed after the post-annealing processes. The photoluminescence spectra of the broad light emission in the visible range shifted to the long wavelength and were saturated above an annealing temperature of $900^{\circ}C$ or after 1 hour annealing at $970^{\circ}C$. However, the position of the light emission peak at 380 nm did not change at all after the post-annealing processes. The light emission intensities at 380 nm initially increased, and decreased at annealing temperatures above $700^{\circ}C$ or after 1 hour annealing at $700^{\circ}C$. The photoluminescence behaviors after the annealing processes can be explained bythe size change of the nanocrystalline silicon and the density change of Si=O defect in the films, respectively. These results support the possibility of using a silicon-based light source for Si-optoelectronic integrated circuits and/or display devices.

Unicortical Bone Necrosis of the Fibula Free Flap Associated to the Fixation with a Nonlocking 2.0-mm Reconstruction Plate and Screws

  • Pereira, Gustavo N.;Ribeiro, Diogo;Saraiva, Luis;Freitas, Hugo;Santos, Ana R.
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.413-417
    • /
    • 2022
  • The authors present a unique case of osteonecrosis of a cortical half of a fibula free flap that has not been reported in the literature yet. This complication was associated with the impairment of the vascularization of periosteum in the cortical half of fibula that was fixated with a nonlocking reconstructive 2.0-mm plate and screws but other factors could have been involved. The patient was submitted to excision of a cemento-ossifying fibroma that resulted in a left hemimaxilectomy mesoinfrastructure defect classified as the Cordeiro type 2B. The 42-year-old female patient was submitted to reconstruction with an osteomusculocutaneous fibula free flap plus a segment of fibula graft. The two bone segments of the free flap used to reconstruct the anterior and left alveolar crest were fixated with a reconstructive 2.0-mm plate of matrixMANDIBLE system. The only reported complication was an oronasal fistula that healed with conservative treatment and the referred osteonecrosis of the external cortical half of the fibula free flap with plate exposure at 2.5 years postoperatively. Surgical excision of the osteonecrosed cortical half of the fibula with the plate and screws was performed, while the other cortical underwent bone union as corroborated by computed tomography scans.

Definitive Closure of the Tracheoesophageal Puncture Site after Oncologic Laryngectomy: A Systematic Review and Meta-Analysis

  • Escandon, Joseph M.;Mohammad, Arbab;Mathews, Saumya;Bustos, Valeria P.;Santamaria, Eric;Ciudad, Pedro;Chen, Hung-Chi;Langstein, Howard N.;Manrique, Oscar J.
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.617-632
    • /
    • 2022
  • Tracheoesophageal puncture (TEP) and voice prosthesis insertion following laryngectomy may fail to form an adequate seal. When spontaneous closure of the fistula tract does not occur after conservative measures, surgical closure is required. The purpose of this study was to summarize the available evidence on surgical methods for TEP site closure. A comprehensive search across PubMed, Web of Science, SCOPUS, and Cochrane was performed to identify studies describing surgical techniques, outcomes, and complications for TEP closure. We evaluated the rate of unsuccessful TEP closure after surgical management. A meta-analysis with a random-effect method was performed. Thirty-four studies reporting on 144 patients satisfied inclusion criteria. The overall incidence of an unsuccessful TEP surgical closure was 6% (95% confidence interval [CI] 1-13%). Subgroup analysis showed an unsuccessful TEP closure rate for silicone button of 8% (95% CI < 1-43%), 7% (95% CI < 1-34%) for dermal graft interposition, < 1% (95% CI < 1-37%) for radial forearm free flap, < 1% (95% CI < 1-52%) for ligation of the fistula, 17% (95% CI < 1-64%) for interposition of a deltopectoral flap, 9% (95% CI < 1-28%) for primary closure, and 2% (95% CI < 1-20%) for interposition of a sternocleidomastoid muscle flap. Critical assessment of the reconstructive modality should take into consideration previous history of surgery or radiotherapy. Nonirradiated fields and small defects may benefit from fistula excision and tracheal and esophageal multilayer closure. In cases of previous radiotherapy, local flaps or free tissue transfer yield high successful TEP closure rates. Depending on the defect size, sternocleidomastoid muscle flap or fasciocutaneous free flaps are optimal alternatives.

Surgical Outcomes of Cor Triatriatum Sinister: A Single-Center Experience

  • Kim, Donghee;Kwon, Bo Sang;Kim, Dong-Hee;Choi, Eun Seok;Yun, Tae-Jin;Park, Chun Soo
    • Journal of Chest Surgery
    • /
    • v.55 no.2
    • /
    • pp.151-157
    • /
    • 2022
  • Background: We investigated surgical outcomes after the surgical repair of cor triatriatum sinister (CTS). Methods: Thirty-two consecutive patients who underwent surgical repair of CTS from 1993 through 2020 were included in this study. The morphological characteristics, clinical features, and surgical outcomes were described and analyzed. Results: The median age and body weight at operation were 9 months (interquartile range [IQR], 3-238 months) and 7.5 kg (IQR, 5.8-49.6 kg), respectively. There were 16 males (50%). According to the modified Lucas classification, type IA (classical CTS) was most common (n=20, 62.5%). Atrial septal defect was associated in 22 patients (68.8%) and anomalous pulmonary venous return in 8 patients (25%). Pulmonary hypertension was preoperatively suspected with a high probability in 18 patients (56.3%). There was 1 early death (3.1%) after emergent membrane excision and hybrid palliation in a high-risk hypoplastic left heart syndrome patient. There were no late deaths. The overall survival rate was 96.9% at 15 years post-repair. No early survivors required reoperation during follow-up. Most survivors (31 of 32 patients, 96.9%) were in New York Heart Association functional class I at a median follow-up of 74 months (IQR, 39-195 months). At the latest echocardiography performed at a median of 42 months (IQR, 6-112 months) after repair, no residual lesion was observed except in 1 patient who had moderate pulmonary hypertension (mean pulmonary arterial pressure of 36 mm Hg). Conclusion: Surgical repair of cor triatriatum could be performed safely and effectively with an extremely low risk of recurrence.

Anterior Cranial Base Reconstruction in Complex Craniomaxillofacial Trauma: An Algorithmic Approach and Single-Surgeon's Experience

  • Shakir, Sameer;Card, Elizabeth B.;Kimia, Rotem;Greives, Matthew R.;Nguyen, Phuong D.
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.174-183
    • /
    • 2022
  • Management of traumatic skull base fractures and associated complications pose a unique reconstructive challenge. The goals of skull base reconstruction include structural support for the brain and orbit, separation of the central nervous system from the aerodigestive tract, volume to decrease dead space, and restoration of the three-dimensional appearance of the face and cranium with bone and soft tissues. An open bicoronal approach is the most commonly used technique for craniofacial disassembly of the bifrontal region, with evacuation of intracranial hemorrhage and dural repair performed prior to reconstruction. Depending on the defect size and underlying patient and operative factors, reconstruction may involve bony reconstruction using autografts, allografts, or prosthetics in addition to soft tissue reconstruction using vascularized local or distant tissues. The vast majority of traumatic anterior cranial fossa (ACF) injuries resulting in smaller defects of the cranial base itself can be successfully reconstructed using local pedicled pericranial or galeal flaps. Compared with historical nonvascularized ACF reconstructive options, vascularized reconstruction using pericranial and/or galeal flaps has decreased the rate of cerebrospinal fluid (CSF) leak from 25 to 6.5%. We review the existing literature on this uncommon entity and present our case series of n = 6 patients undergoing traumatic reconstruction of the ACF at an urban Level 1 trauma center from 2016 to 2018. There were no postoperative CSF leaks, mucoceles, episodes of meningitis, or deaths during the study follow-up period. In conclusion, use of pericranial, galeal, and free flaps, as indicated, can provide reliable and durable reconstruction of a wide variety of injuries.

Tissue Expanders in Staged Calvarial Reconstruction: A Systematic Review

  • Andrea Y. Lo;Roy P. Yu;Anjali C. Raghuram;Michael N. Cooper;Holly J. Thompson;Charles Y. Liu;Alex K. Wong
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.729-739
    • /
    • 2022
  • Cranioplasties are common procedures in plastic surgery. The use of tissue expansion (TE) in staged cranioplasties is less common. We present two cases of cranioplasties with TE and systematically review literature describing the use of TE in staged cranioplasties and postoperative outcomes. A systematic review was performed by querying multiple databases. Eligible articles include published case series, retrospective reviews, and systematic reviews that described use of TE for staged bony cranioplasty. Data regarding study size, patient demographics, preoperative characteristics, staged procedure characteristics, and postoperative outcomes were collected. Of 755 identified publications, 26 met inclusion criteria. 85 patients underwent a staged cranioplasty with TE. Average defect size was 122 cm2, and 30.9% of patients received a previous reconstruction. Average expansion period was 14.2 weeks. The most common soft tissue closures were performed with skin expansion only (75.3%), free/pedicled flap (20.1%), and skin graft (4.7%). The mean postoperative follow-up time was 23.9 months. Overall infection and local complication rates were 3.53 and 9.41%, respectively. The most common complications were cerebrospinal fluid leak (7.1%), hematoma (7.1%), implant exposure (3.5%), and infection (3.5%). Factors associated with higher complication rates include the following: use of alloplastic calvarial implants and defects of congenital etiology (p = 0.023 and 0.035, respectively). This is the first comprehensive review to describe current practices and outcomes in staged cranioplasty with TE. Adequate soft tissue coverage contributes to successful cranioplasties and TE can play a safe and effective role in selected cases.

Electronic properties of graphene nanoribbons with Stone-Wales defects using the tight-binding method

  • M.W. Chuan;S.Z. Lok;A. Hamzah;N.E. Alias;S. Mohamed Sultan;C.S. Lim;M.L.P Tan
    • Advances in nano research
    • /
    • v.14 no.1
    • /
    • pp.1-15
    • /
    • 2023
  • Driven by the scaling down of transistor node technology, graphene became of interest to many researchers following the success of its fabrication as graphene nanoribbons (GNRs). However, during the fabrication of GNRs, it is not uncommon to have defects within the GNR structures. Scaling down node technology also changes the modelling approach from the classical Boltzmann transport equation to the quantum transport theory because the quantum confinement effects become significant at sub-10 nanometer dimensions. The aim of this study is to examine the effect of Stone-Wales defects on the electronic properties of GNRs using a tight-binding model, based on Non-Equilibrium Green's Function (NEGF) via numeric computation methods using MATLAB. Armchair and zigzag edge defects are also implemented in the GNR structures to mimic the practical fabrication process. Electronic properties of pristine and defected GNRs of various lengths and widths were computed, including their band structure and density of states (DOS). The results show that Stone-Wales defects cause fluctuation in the band structure and increase the bandgap values for both armchair GNRs (AGNRs) and zigzag GNRs (ZGNRs) at every simulated width. In addition, Stone-Wales defects reduce the numerical computation DOS for both AGNRs and ZGNRs. However, when the lengths of the structures increase with fixed widths, the effect of the Stone-Wales defects become less significant.