• Title/Summary/Keyword: Multiple reference image

Search Result 96, Processing Time 0.029 seconds

Performance Evaluation and Verification of MMX-type Instructions on an Embedded Parallel Processor (임베디드 병렬 프로세서 상에서 MMX타입 명령어의 성능평가 및 검증)

  • Jung, Yong-Bum;Kim, Yong-Min;Kim, Cheol-Hong;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.10
    • /
    • pp.11-21
    • /
    • 2011
  • This paper introduces an SIMD(Single Instruction Multiple Data) based parallel processor that efficiently processes massive data inherent in multimedia. In addition, this paper implements MMX(MultiMedia eXtension)-type instructions on the data parallel processor and evaluates and analyzes the performance of the MMX-type instructions. The reference data parallel processor consists of 16 processors each of which has a 32-bit datapath. Experimental results for a JPEG compression application with a 1280x1024 pixel image indicate that MMX-type instructions achieves a 50% performance improvement over the baseline instructions on the same data parallel architecture. In addition, MMX-type instructions achieves 100% and 51% improvements over the baseline instructions in energy efficiency and area efficiency, respectively. These results demonstrate that multimedia specific instructions including MMX-type have potentials for widely used many-core GPU(Graphics Processing Unit) and any types of parallel processors.

A study on RDM algorithm for document image and application to digital signature (문서화상에 대한 RDM 합성 알고리즘 및 디지틀 서명에의 응용)

  • 박일남;이대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3056-3068
    • /
    • 1996
  • This papre presents the RDM algorithm for composition of bit. After this, we propose a digital signature scheme for facsimile document using RDM algorithm. We modify the even-odd feature in distance of changing pel between coding line and multiple reference line which have been scanned before, and run-length in coding line. The time to take in signature is reduced by spreading of signature. Non-repudiation in origin, the 3rd condition of digital signature is realized by proposed digital signature scheme. The transmitter embeds the signature secretly and tensfers it, and the receiver makes a check of any forgery on the signature and the document. This scheme is compatible with the ITU-T.4(G3 or G4 facsimile standard). The total amount of data transmitted and the quality of image are about the same to that of the original document, thus a third party does not notics signature embeded on the document.

  • PDF

Usability of 2D/2D Match for Image Guided Radiotherapy (IGRT) of Prostate Cancer with Fiducial Markers (전립선 암 환자의 영상유도 방사선 치료 시 Fiducial Marker를 이용한 2D/2D Match의 유용성에 대한 연구)

  • Bae, Sun-Myung;Yang, Oh-Nam;Song, Heung-Kwon;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: To study the efficacy of marker match with using kilovoltage (KV) X-ray among multiple image guidance that referring tree fiducial marker in radiation therapy for prostate cancer patients. Materials and Methods: KV two-dimantional images (anterior-posterior, right-left) and cone-beam CT volumetric images were acquired after setup for patients with three fiducial markers. Compare the position of the fiducial marker of reference plan computed tomography (CT) and of KV, CBCT images; then decide the shift score of X, Y, and Z. This study executed 5 times on 10 patients and analyzed the shift value. Results: In the radiation therapy using fiducial marker, The function of marker match showed the same direction tendency as the CBCT, and showed X, Y, Z difference of about 0.6, 0.7, and 0.8 (unit: mm). Conclusion: Comparing to this, the result of shift value using 2D marker match showed less than 1.0 mm difference. The function of marker match is considered more useful in time-wise and effective dose rather than CBCT. Therefore, Both methods are used to treat patients for prostate cancer.

  • PDF

Comparison of Co-registration Algorithms for TOPS SAR Image (TOPS 모드 SAR 자료의 정합기법 비교분석)

  • Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1143-1153
    • /
    • 2018
  • For TOPS InSAR processing, high-precision image co-registration is required. We propose an image co-registration method suitable for the TOPS mode by comparing the performance of cross correlation method, the geometric co-registration and the enhanced spectral diversity (ESD) matching algorithm based on the spectral diversity (SD) on the Sentinel-1 TOPS mode image. Using 23 pairs of interferometric pairs generated from 25 Sentinel-1 TOPS images, we applied the cross correlation (CC), geometric correction with only orbit information (GC1), geometric correction combined with iterative cross-correlation (GC2, GC3, GC4), and ESD iteration (ESD_GC, ESD_1, ESD_2). The mean of co-registration errors in azimuth direction by cross correlation and geometric matching are 0.0041 pixels and 0.0016 pixels, respectively. Although the ESD method shows the most accurate result with the error of less than 0.0005 pixels, the error of geometric co-registration is reduced to 0.001 pixels by repetition through additional cross correlation matching between the reference and resampled slave image. The ESD method is not applicable when the coherence of the burst overlap areas is low. Therefore, the geometric co-registration method through iterative processing is a suitable alternative for time series analysis using multiple SAR data or generating interferogram with long time intervals.

Design of High-Performance Motion Estimation Circuit for H.264/AVC Video CODEC (H.264/AVC 동영상 코덱용 고성능 움직임 추정 회로 설계)

  • Lee, Seon-Young;Cho, Kyeong-Soon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.53-60
    • /
    • 2009
  • Motion estimation for H.264/AVC video CODEC is very complex and requires a huge amount of computational efforts because it uses multiple reference frames and variable block sizes. We propose the architecture of high-performance integer-pixel motion estimation circuit based on fast algorithms for multiple reference frame selection, block matching, block mode decision and motion vector estimation. We also propose the architecture of high-performance interpolation circuit for sub-pixel motion estimation. We described the RTL circuit in Verilog HDL and synthesized the gate-level circuit using 130nm standard cell library. The integer-pixel motion estimation circuit consists of 77,600 logic gates and four $32\times8\times32$-bit dual-port SRAM's. It has tile maximum operating frequency of 161MHz and can process up to 51 D1 (720$\times$480) color in go frames per second. The fractional motion estimation circuit consists of 22,478 logic gates. It has the maximum operating frequency of 200MHz and can process up to 69 1080HD (1,920$\times$1,088) color image frames per second.

Automated Clothing Analysis System through Image Analysis (이미지 분석을 통한 자동화 의류 분석 시스템)

  • Choi, Moon-hyuk;Lee, Seok-jun;Lee, Hak-jae;Kim, So-yeong;Moon, Il-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.313-315
    • /
    • 2019
  • Although Korea's fashion market has negative growth, it has been growing again since 2018. This phenomenon means that people are becoming more interested in fashion. As interest in fashion grows, people visit various community sites for reference to find a suitable coordination for themselves. Most community sites, however, are manually categorizing each garment. Not only do these tasks take a lot of time, but they also make it difficult to search for multiple clothing at the same time. In other words, I can't choose what I want at the same time, and if I choose what I want, I have to look at what the model is wearing and refer to it. The problem with this may not help because the coordination in which the model provided is worn is more likely to be the one that the user does not want. In this paper, when the image is uploaded to improve the problem, the clothing is analyzed with AI analysis model and automatically classified and stored. Therefore, not only can you search for one clothes in the existing way, but you can also search for multiple clothes at the same time. The service is expected to allow more people to easily find and refer to the code for themselves.

  • PDF

3D Visual Attention Model and its Application to No-reference Stereoscopic Video Quality Assessment (3차원 시각 주의 모델과 이를 이용한 무참조 스테레오스코픽 비디오 화질 측정 방법)

  • Kim, Donghyun;Sohn, Kwanghoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.110-122
    • /
    • 2014
  • As multimedia technologies develop, three-dimensional (3D) technologies are attracting increasing attention from researchers. In particular, video quality assessment (VQA) has become a critical issue in stereoscopic image/video processing applications. Furthermore, a human visual system (HVS) could play an important role in the measurement of stereoscopic video quality, yet existing VQA methods have done little to develop a HVS for stereoscopic video. We seek to amend this by proposing a 3D visual attention (3DVA) model which simulates the HVS for stereoscopic video by combining multiple perceptual stimuli such as depth, motion, color, intensity, and orientation contrast. We utilize this 3DVA model for pooling on significant regions of very poor video quality, and we propose no-reference (NR) stereoscopic VQA (SVQA) method. We validated the proposed SVQA method using subjective test scores from our results and those reported by others. Our approach yields high correlation with the measured mean opinion score (MOS) as well as consistent performance in asymmetric coding conditions. Additionally, the 3DVA model is used to extract information for the region-of-interest (ROI). Subjective evaluations of the extracted ROI indicate that the 3DVA-based ROI extraction outperforms the other compared extraction methods using spatial or/and temporal terms.

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

On Shape Recovery of 3D Object from Multiple Range Images (시점이 다른 다수의 거리 영상으로부터 3차원 물체의 형상 복원)

  • Kim, Jun-Young;Yun, Il-Dong;Lee, Sang-Uk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.1
    • /
    • pp.1-15
    • /
    • 2000
  • To reconstruct 3- D shape, It is a common strategy to acquire multiple range Images from different viewpoints and integrate them into a common coordinates In this paper, we particularly focus on the registration and integration processes for combining all range Images into one surface model. For the registration, we propose the 2-step registration algorithm, which consists of 2 steps the rough registration step using all data points and the fine registration step using the high-curved data points For the integration, we propose a new algorithm, referred to as ‘multi-registration’ technique, to alleviate the error accumulation problem, which occurs during applying the pair-wise registration to each range image sequentially, in order to transform them into a common reference frame Intensive experiments are performed on the various real range data In experiments, all range images were registered within 1 minutes on Pentium 150MHz PC The results show that the proposed algorithms registrate and integrate multiple range Images within a tolerable error bound in a reasonable computation time, and the total error between all range Images are equalized with our proposed algorithms.

  • PDF

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF