• 제목/요약/키워드: Multiple electrodes

검색결과 97건 처리시간 0.032초

코발트전극과 자동시험장치를 이용한 파프리카 양액 내 무기인산 측정 (Determination of Inorganic Phosphate in Paprika Hydroponic Solution using a Laboratory-made Automated Test Stand with Cobalt-based Electrodes)

  • 김학진;손동욱;권순구;노미영;강창익;정호섭
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.326-333
    • /
    • 2011
  • The need for rapid on-site monitoring of hydroponic macronutrients has led to the use of ion-selective electrodes, because of their advantages over spectrophotometric methods, including simple methodology, direct measurement of analyte, sensitivity over a wide concentration range, and low cost. Stability and repeatability of response can be a concern when using multiple ion-selective electrodes to measure concentrations in a series of samples because accuracy might be limited by drifts in electrode potential. A computer-based measurement system could improve accuracy and precision because of both consistent control of sample preparation and easy calibration of sensors. Our goal was to investigate the applicability of a cobalt-based electrode used in conjunction with a laboratory-made automated test stand for quantitative determination of ${PO_4}^-$ in hydroponic solution. Six hydroponic solutions were prepared by diluting highly concentrated paprika hydroponicsolution to provide a concentration range of 1 to 300 ppm $PO_4$-P. A calibration curve relating electrode response to phosphate in paprika hydroponic solution titrated to pH 4 with 0.025M KHP was developed based on the Nikolskii-Eisenman equation with a coefficient of determination ($R^2$) of 0.94. The laboratory-made test stand consisting of three cobalt-based electrodes measured phosphate concentrations similar to those obtained with standard laboratory methods (a regression slope of 0.98 with $R^2$ = 0.80). However, the y intercept was relatively high, 30 ppm, probably due to the relatively large amount of variation present among multiple measurements of the same sample. Further studies on the high variation in EMFs obtained with cobalt electrodes during replicate measurements were required for P estimations comparable to those obtained with standard laboratory instruments.

메쉬접지극의 접지저항에 관한 실증연구 (An experimental research about the grounding resistance of the mesh electrode in the model of water tank)

  • 김주찬;최종규;이충식;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.349-354
    • /
    • 2005
  • Recently, there are many equipment of electricity, electronics, and communication which need to grounding in the building. When the electric current flows into a certain grounding system in the same building, the potential rise of other grounding system is possible to be affected by its potential rise. This potential interference was affected by the surface potential, it is deeply related whit the electrode shape. In this paper, basic formula is deduced on the basis of both electrodes surface potential of grounding electrode in a source of the potential interference and groundidng electrode which receive the potential interference. Therefore the degree of potential interference as multiple groundidng electrode can be verified the simulated results by means of the simple model in advance. This is for investigating the grounding resistance of grounding electrodes, the experiment was performed with model-scale of the grounding system and the scaled model grounding system was to this experiment using a water tank of a stainless steel-hemisphere shape. since mesh electrodes have been widely in the general building, we're tried to analyze that this water tank model and it's simulation as well.

  • PDF

Surface EMG Network Analysis and Robotic Arm Control Implementation

  • Ryu, Kwang-Ryol
    • Journal of information and communication convergence engineering
    • /
    • 제9권6호
    • /
    • pp.743-746
    • /
    • 2011
  • An implementation for surface EMG network analysis and vertical control system of robotic arm is presented in this paper. The transmembranes are simulated by equivalent circuit and cable equation for propagation to be converted to circuit networks. The implementation is realized to be derived from the detecting EMG signal from 3 electrodes, and EMG transmembrane signals of human arm muscles are detected by several surface electrodes, high performance amplifier and filtering, converting analog to digital data and driving a servomotor for spontaneous robotic arm. The system is experimented by monitoring multiple steps vertical control angles corresponding to biceps muscle movement. The experimental results are that the vertical moving control level is measured to around 2 degrees and mean error ranges are lower 5%.

A Study on Gene Detection using Non-labeling DNA

  • Choi Yong-Sung;Lee Kyung-Sup;Kwon Young-Soo
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.960-965
    • /
    • 2006
  • This research aims to develop the multiple channel electrochemical DNA chip using microfabrication technology. At first, we fabricated a high integration type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then target DNAs were hybridized and reacted. Cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. Therefore, it is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

파동형 움직임이 가능한 다자유 IPMC 구동기 제작 (Fabrication of MDOF IPMC Actuators to Generate Undulatory Motion)

  • 전진한;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.119-123
    • /
    • 2006
  • The ionic-polymer-metal-composite actuators have the best merit for bio-mimetic locomotion because of their large bending performance. Especially, they have the advantage for mimicking a fish-like motion because IPMCs are useful to be actuated in water. So we have developed IPMC actuators with multiple electrodes for realization of biomimetic motion. Generally, the IPMC actuator has been fabricated in electroless plating technique, while it needs very long fabrication time and shows poor repeatability in the actuation performance owing to the variables in chemical fabrication process. Therefore, the novel fabrication methods were investigated by combining electroless plating and electroplating techniques capable of patterning precisely. On the whole, two different methods were compared and analyzed with similar thickness level of Platinum electrodes. Present results show that mixing chemical reduction and electroplating can be a promising candidate for electrode patterning.

  • PDF

각판상전극의 접지저항에 관한 연구 (Research on Grounding Resistance for the Grounding Plate Electrodes)

  • 고희석;신수한;김주찬;최종규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2004
  • There are many electricity, electronics, and communication equipment which need to Grounding in the building. When electric current flows into a certain Grounding system in the same building, the potential of other Grounding system rises. This potential interference repuire surface potential of electrods by electrode shape. In this paper basic formula is deduced on the basis of both electrodes surface potential of Grounding electrode as a source of the potential interference and Grounding electrode which receive the potential interference. The degree of potential interference as multiple Grounding electrode is verified the simulated results by means of the simple model in advance.

  • PDF

$Nb/A1O_x/Nb$ 조셉슨 접합에서 저항측정을 이용한 Nb 전극의 침투깊이 측정 (Determination of Penetration Depth of Nb Electrodes in $Nb/A1O_x/Nb$ Josephson Junction by Resistive Method)

  • 김동호;김규태;박종원;황준석;홍현권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.50-54
    • /
    • 2002
  • Penetration depth of Nb electrodes in $Nb/A1O_x/Nb$ Josephson junctions has been measured by resistive method. For a given applied field, the total flux through the junction is temperature dependent because the penetration depth of Nb electrode varies with temperature. If the total flux equals an integral multiple of the flux quantum at certain temperatures, resistive peaks appear at those temperatures. The penetration depth of Nb can be determined by applying the above condition, The temperature dependence of penetration depth was found to be well described by the two-fluid model.

접지극의 전위간섭 (Potential Interference between the Earth Electrode)

  • 김주찬;김성삼;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.48-52
    • /
    • 2004
  • Recently, there are many electricity, electronics, and communication equipment which need to earthing in the building. When electric current flows into a certain earthing system in the same building, the potential of other earthing system rises. This potential interference repuire surface potential of electrodes by electrode shape. In this paper basic formula is deduced on the basis of both electrodes surface potential of earth electrode as a source of the potential interference and earth electrode which receive the potential interference. The degree of potential interference as multiple earth electrode is verified the simulated results by means of the simple model in advance.

  • PDF

차세대형 바이오칩의 개발 및 비수식화 표적 DNA를 이용한 유전자 검출 (Development of New Biochip and Genome Detection Using an Non-labeling Target DNA)

  • 최용성;박대희;권영수;천합지인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.51-53
    • /
    • 2002
  • This research aims to develop a multiple channel electrochemical DNA chip using micro-fabrication technology. At first, we fabricated a high integrated type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the sold electrodes. Then target DNAs were hybridized by an electrical force. Redox peak of cyclic-voltammogram showed a difference between target DNA and mismatched DNA in the anodic peak current. Therefore, it is able to detect a various genes electrochemically after immobilization of a various probe DNA and hybridization of label-free DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

비수식화 바이오칩 및 유전자 검출 (Genome Detection Using an DNA Chip Array and Non-labeling DNA)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.402-403
    • /
    • 2006
  • This research aims to develop the multiple channel electrochemical DNA chip using microfabrication technology. At first, we fabricated a high integration type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then target DNAs were hybridized and reacted. Cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. Therefore, it is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF