• Title/Summary/Keyword: Multiple chemical sensitivity

Search Result 31, Processing Time 0.026 seconds

Enhancement of Sensitivity in Interferometric Biosensing by Using a New Biolinker and Prebinding Antibody

  • Park, Jae-Sook;Lim, Sung-Hyun;Sim, Sang-Jun;Chae, Hee-Yeop;Yoon, Hyun-C.;Yang, Sang-Sik;Kim, Byung-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.12
    • /
    • pp.1968-1976
    • /
    • 2006
  • Recombinant E. coli ACV 1003 (recA:: lacZ) was used to measure low concentrations of DNA-damaging chemicals, which produce $\beta$-galactosidase via an SOS regulon system. Very low $\beta$-galactosidase activities of less than 0.01 unit/ml, $\beta$-galactosidase produced through an SOS response corresponding to the 10 ng/ml (ppb) of DNA damaging chemicals in the environment, can be rapidly determined by using an alternative interferometric biosensor with optically flat thin films of porous silicon rather than by the conventional time-consuming Miller's enzyme assay as well as the ELISA method. fu order to enhance the sensitivity in the interferometry, it needs to obtain more uniform distribution and higher biolinking efficiency, whereas interferometric sensing is rapid, cheap, and advantageous in high throughput by using a multiple-well-type chip. In this study, pore size adjusted to 60 nm for the target enzyme $\beta$-galactosidase to be bound on both walls of a Si pore and a calyx crown derivative was apllied as a more efficient biolinker. Furthermore, anti-$\beta$-galactosidase was previously functionalized with the biolinker for the target $\beta$-galactosidase to be specifically bound. When anti-$\beta$-galactosidase was bound to the calyx-crown derivative-linked surface, the effective optical thickness was found to be three times as high as that obtained without using anti-$\beta$-galactosidase. The resolution obtained was very similar to that afforded by the time-consuming ELISA method; however, the reproducibility was still unsatisfactory, below 1 unit $\beta$-galactosidase/ml, owing to the microscopic non-uniform distribution of the pores in the etched silicon surface.

The Research about the Risk Assessment by Job Groups in Construction Worker (건설업종사자의 직군별 화학물질과민증 위해성 평가에 관한 연구)

  • Sung, Ki-Chul;Chun, Chung-Yoon;Park, Jun-Seok
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.295-300
    • /
    • 2005
  • This Study intends to find out the subjective symptom of Construction Business Worker caused by chemical material exposure, also willing to research how much they are exposed to VOCs(Volatile Organic Compounds) and under how much harmful circumstance they are working. As the results, the job group among construction business workers which is most highly dangerous degree to be taken ill of Multiple Chemical Sensitivity is Interior Worker, next following by order of Clerical Worker, Exterior Worker. According to this result, the continuous exposure in high density must be prevented by the measures for Interior Worker also to be bestowed a compulsory break during working hour for regular exposure to the open air,

  • PDF

Recent Progress in Multiplexed Detection of Biomarkers Based on Quantum Dots (양자점 기반 다중 바이오마커 검출법의 연구동향)

  • Kim, Yerin;Choi, Yu Rim;Kim, Bong-Geun;Na, Hyon Bin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.451-458
    • /
    • 2022
  • Semiconductor quantum dots (QDs) are optical probes with excellent fluorescence properties. Therefore, they have been applied to various bio-medical imaging techniques and biosensors. Due to the unique optical characteristics of wide absorption and narrow fluorescence energy bands, multiple types of signals can be generated by the combination of fluorescence wavelengths from different QDs, which enables the simultaneous detection of more than two biomarkers. In this review, the advantages and applications of QDs and QD nanobeads (QBs) in multiple biomarker assays were described, and new developments or improvements in multiplexed biomarker detection techniques were summarized. In particular, recent reports were summarized, focusing on the design strategies in immunoassay construction and signal transducing materials for fluorescence-linked immunosorbent assays using QDs and immunochromatographic assays using QBs. New detection platforms will be developed for early diagnosis of diseases and other fields if multiplexed detection technologies of excellent accuracy and sensitivity are combined with artificial intelligence algorithms.

MCS/IEI Prevalence Rate of Workers Around an Accidental Release of Hydrogen Fluoride in Gumi Industrial Complex (구미공단 불화수소 누출사고 주변 지역 근로자들의 화학물질과민증 유병률)

  • Han, Hye-Ji;Woo, Kuck-Hyeun;Choi, Sung-Yong;Jeon, Byoung-Hak;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.534-541
    • /
    • 2015
  • Objectives: This study was conducted to evaluate the prevalence rate of multiple chemical sensitivity/idiopathic environmental intolerance(MCS/IEI) among workers in the Gumi industrial complex around the region of accidental release of hydrogen fluoride in 2012. Materials: We evaluated MCS/IEI using the Korean version of the Quick Environmental Exposure and Sensitivity Inventory(QEESI). A total of 535 workers at six manufacturing companies in the Gumi industrial complex were investigated using self-administered questionnaires from February to March 2015. After exclusion of incompletely answered questionnaires, 271 were analyzed. Results: The prevalence rate and proved positive rate of MCS/IEI were 5.9%(16 out of 271) and 3.7%(10 out of 271), respectively. The scores of chemical intolerance, other intolerance, symptom severity and life impact were significantly higher(p<0.05) in females than those of males. In terms of masking index scores, males showed significantly higher(p=0.003) than female. The self-reported MCS/IEI prevalence rate, 7.7%, of workers exposed to hydrogen fluoride in 2012 was higher than no-exposure group(5.6%), but not statistically significant(p=0.815). Conclusions: Although the prevalence rate of MCS/IEI symptoms of workers exposed to hydrogen fluoride gas in 2012 was not significantly higher than no-exposure group, it is necessary to conduct follow-up study on the exposure group of hydrogen fluoride.

A Study on Corps / Division Operation Analysis Using Simplified Corps Level Wargame Model (군단급 간이분석 워게임모형을 이용한 군단 및 사단 작전분석 방안 연구)

  • 박승환;강성진
    • Journal of the military operations research society of Korea
    • /
    • v.24 no.2
    • /
    • pp.95-116
    • /
    • 1998
  • Many different kinds of wargame models have been developed and used in training and analysis purpose. However, there has been few wargame model which analyze corps or division level operational analysis. Recently KIDA develops corps level operational analysis model based on START(simplified tool for analysis of regional treats) model developed by RAND. This model runs in a PC level with 2MB memory and provides one day combat results within 30 seconds. Only one or three person can operate this model and evaluate multiple corps level operational analysis including chemical effects, $C^3I$ capacity, new weapon system effectiveness and other qualitative effects. We tested this model and evaluated input and output data. We showed that this model can be applied in division level operational analysis also. As an example division level application procedure and sensitivity analysis data was provided. We also find some limitation and problems in the model and suggest application areas and improving methods.

  • PDF

Numerical Study on Flame Structure and Pollutant Formation for Syngas Turbulent Nonpremixed Swirl Burner (석탄가스 선회난류 연소기의 화염구조 및 공해물질 배출특성 해석)

  • Lee, Jeong-Won;Kang, Sung-Mo;Kim, Yong-Mo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.449-452
    • /
    • 2007
  • The present study numerically investigate the effects of the Syngas chemical kinetics on the basic flame properties and the structure of the Syngas diffusion flames. In order to realistically represent the turbulence-chemistry interact ion and the spatial inhomogeneity of scalar dissipation rate. the Eulerian Particle Flamelet Model(EPFM) with multiple flamelets has been applied to simulate the combustion processes and NOx formation in the syngas turbulent nonpremixed flames. Due to the ability for interactively describing the transient behaviors of local flame structures with CFD solver, the EPFM model can effectively account for the detailed mechanisms of NOx format ion including thermal NO path, prompt and nitrous NOx format ion, and reburning process by hydrocarbon radical without any ad-hoc procedure. validation cases include the Syngas turbulent nonpremixed jet and swirling flames. Based on numerical results, the detailed discussion has been made for the sensitivity of the Syngas chemical kinetics as well as the precise structure and NOx formation characteristics of the turbulent Syngas nonpremixed flames.

  • PDF

Simultaneous Determination of the Novel Neuroprotective Agent KR-31378 and its Metabolite KR-31612 Using High Performance Liquid Chromatography with Tandem Mass Spectrometry in Human Plasma

  • Kim, John;Ji, Hye-Young;Yoo, Sung-Eun;Kim, Sun-Ok;Lee, Dong-Ha;Lim, Hong;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.647-651
    • /
    • 2002
  • An LC/MS/MS method for the simultaneous determination of a neuroprotective agent for ischemia-reperfusion damage, KR-31378 and its N-acetyl metabolite KR-31612 in human plasma was developed. KR-31378, KR-31612 and the internal standard. KR-31543 were extracted from human plasma by liquid-liquid extraction. A reverse-phase HPLC separation was performed on Luna phenylhexyl column with the mixture of acetonitrile-5 mM ammonium formate (55:45, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple reaction monitoring mode. The lower limits of quantification for KR-31378 and KR-31612 were 2.0 ng/ml. The method showed a satisfactory sensitivity, precision, accuracy, recovery and selectivity.

Determination of Free Amino Acids in Isatidis Radix By HILIC-UPLC-MS/MS

  • Pan, Yilin;Li, Jin;Li, Xiang;Chen, Jianwei;Bai, Ganggang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.197-203
    • /
    • 2014
  • A rapid, accurate and precise method for the determination of 22 amino acids in Isatidis Radix by Hydrophilic Interaction Ultra-High-Performance Liquid Chromatography Coupled with Triple-Quadrupole Mass Spectrometry (HILIC-UPLC-MS/MS) was established. Chromatographic separation was carried out on a Acquity UPLC BEH Amide column ($2.1mm{\times}100mm$, $1.7{\mu}m$) with gradient elution of acetonitrile (containing 0.05% formic acid and 2 mM ammonium formate) and water (containing 0.15% formic acid and 10 mM ammonium formate) at a flow rate of 0.4 mL/min; Waters Xevo$^{TM}$ TQ worked in multiple reaction monitoring mode. All components were separated in 17 min. All calibration curves were linear ($R^2$ > 0.991) over the tested ranges. The limits of detection (LOD) and limits of quantitation (LOQ) for these compounds were 0.21-79.55 and 0.72-294.23 ng/mL, respectively. The average recoveries were in the range of 93.75-104.16% with RSD value less than 6.56%. Therefore, this method could be an alternative assay for the determination of 22 amino acids in Isatidis Radix due to its rapidness, sensitivity, less sample and solvent consumption.

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

A Study on Glucose Sensing Measured by Catalyst Containing Multiple Layers of Glucose Oxidase and Gold Nano Rod (글루코스산화효소와 금나노로드 입자의 다층막으로 구성된 촉매를 이용하여 측정한 글루코스 센싱에 대한 연구)

  • Chung, Yong-Jin;Hyun, Kyuhwan;Han, Sang Won;Min, Ji Hong;Chun, Seung-Kyu;Koh, Won-Gun;Kwon, Yongchai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.2
    • /
    • pp.179-183
    • /
    • 2015
  • In this study, we propose a catalyst structure including enzyme and metal nano rod for glucose sensing. In the catalyst structure, glucose oxidase (GOx) and gold nano rod (GNR) are alternatingly immobilized on the surface of carbon nanotube (CNT), while poly(ethyleneimine) (PEI) is inserted in between the GOx and GNR to fortify their bonding and give them opposite polarization ($[GOx/GNR]_nPEI/CNT$). To investigate the impact of $[GOx/GNR]_nPEI/CNT$ on glucose sensing, some electrochemical measurements are carried out. Initially, their optimal layer is determined by using cyclic voltammogram and as a result of that, it is proved that $[GOx/GNR/PEI]_2/CNT$ is the best layer. Its glucose sensitivity is $13.315{\mu}AmM^{-1}cm^{-2}$. When it comes to the redox reaction mechanism of flavin adenine dinucleotide (FAD) within $[GOx/GNR/PEI]_2/CNT$, (i) oxygen plays a mediator role in moving electrons and protons generated by glucose oxidation reaction to those for the reduction reaction of FAD and (ii) glucose does not affect the redox reaction of FAD. It is also recognized that the $[GOx/GNR/PEI]_3/CNT$ is limited to the surface reaction and the reaction is quasi-reversible.