• Title/Summary/Keyword: Multiphase Pump

Search Result 10, Processing Time 0.035 seconds

Development of Multiphase Pump for Offshore Plant (해양플랜트용 다상유동 펌프 개발)

  • Kim, Joonhyung;Choi, Youngseok;Yoon, Joonyong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.183-190
    • /
    • 2014
  • A multiphase pump was developed in this study. The optimum multiphase pump design was arrived at, and the interactions among the different geometric configurations were explained by applying numerical analysis and the DOE (design of experiments) method. First, we designed the base model to meet the specifications. Then, we defined the design parameters related to the meridional plane and the blade angle. Each design parameter was used for generating experiment sets, and numerical analyses were performed on these sets. Finally, the optimized design was selected based on the results of the DOE analysis. The numerical optimization resulted in the optimum model having higher efficiency than the base model. In addition, performance degradation due to changes in the GVF (gas volume fraction) is discussed.

An Outlook on Rotordynamic Pump Theory Development

  • Ni, Yongyan;Pan, Zhongyong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.99-118
    • /
    • 2017
  • ECHO progress was defined to depict the rotordynamic pump theory development. Experience (E) era for pumps lasted nearly one and a half hundred years before the Industrial Revolution due to the low rotation speed of motor and undeveloped manufacture ability. Classic (C) theory referring to quasi-static performance as well as the items those were not able to be steadily resolved under the level were briefly and sophisticated outlined. Since 1962, flow instabilities and the dynamic responses had come into main attention with the development of the modern technologies such as ballistic missile, rocket and space shuttle main engine, and were finally heuristically (H) elucidated by talented scholars and researchers. Recently, new applications for the pumps open (O) to the surrounding fluid and diversity of the medium such as multiphase flow need more studies and some examples were briefly introduced to display the potential problems lastly.

NUMERICAL CODE DEVELOPMENT OF THE MULTIPHASE FLOW AROUND AN UNDERWATER VEHICLE UNDER SUBMARINE WAKE. (후류중에 있는 수중운동체의 캐비테이션 유동 현상 및 유체력 변화 해석 코드 개발)

  • Park, S.I.;Ha, C.T.;Park, W.G.;Lee, K.C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.115-121
    • /
    • 2010
  • Cavitating flow is widely shown in many engineering systems, such as marine propellers, pump impellers, nozzles, injectors, torpedoes, etc. The present work focuses on the numerical analysis of the multiphase flow around the underwater vehicle which was launched from a submarine. The governing equation is the Navier-Stokes equation with a homogeneous mixture mode. The multiphase flow solver uses an implicit preconditioning scheme in curvilinear coordinate. For the code validation, the results from the present work are compared with the existing experimental and numerical results, and a reasonably good agrements are obtained. The multiphase flow around an underwater vehicle is simulated which includes submarine wake effects.

  • PDF

Vortex Cavitation from Baffle Plate and Pump Vibration in a Double-Suction Volute Pump

  • Sato, Toshiyuki;Nagahara, Takahide;Tanaka, Kazuhiro;Fuchiwaki, Masaki;Shimizu, Fumio;Inoue, Akira
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.76-83
    • /
    • 2011
  • This study highlights especially the mechanism of vortex cavitation occurrence from the end of the suction duct in a double-suction volute pump and pump oscillation which causes cavitation noise from the pump. In this study, full 3D numerical simulations have been performed using a commercial code inside the pump from the inlet of suction duct to the outlet of delivery duct. The numerical model is based on a combination of multiphase flow equations with the truncated version of the Rayleigh-Plesset model predicting the complicated growth and collapse process of cavity bubbles. The experimental investigations have also been performed on the cavitating flow with flow visualization to evaluate the numerical results.

AN INVESTIGATION OF SURFACE VORTICES BEHAVIOR IN PUMP SUMP

  • Kang, Won-Tae;Shin, Byeong-Rog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.592-595
    • /
    • 2011
  • A numerical investigation on a suction vortices, free vortices and subsurface vortices behavior in the model sump system with multi-intakes is performed A test model sump and piping system were designed based on Froude similitude for the prototype of the recommended structure layout by HI-9.B Standard for Pump Intake Design of the Hydraulic Institute. A numerical analysis of three dimensional multiphase flows through the model sump is performed by using the finite volume method of the CFX code with multi-block structured grid systems. A ${\kappa}-{\omega]$ ShearStressTransportturbulencemodelandthe Rayleigh-Plesset cavitation model are used for solving turbulence cavitating flow. From the numerical analysis, several types of vortices are reproduced and their formation, growing shedding and detailed vortex structures are investigated. To reduce abnormal vortices, an anti-vortex device is considered and its effect is investigated and discussed.

  • PDF

Study on flow characteristics of the grit chamber using VOF multi-phase flow simulations (VOF 다상유동 해석을 이용한 침사지 유동특성 연구)

  • Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.2
    • /
    • pp.63-73
    • /
    • 2021
  • It is essential to accurately predict the change in water level, velocity, and flow rate for each passage of the grit chamber according to the operating conditions of the pump. In this study, VOF multiphase flow analysis was performed, and the flow characteristics of the grit chamber were predicted. As a result of simulations, the sedimentation phenomenon after the entrance of the grit chamber channel is expected to occur on the side walls. When 6 channels are used, the average speed of the channels is about 52% of the design standard, and when 4 channels are used, the value increases to 74% of the design standard. The average water level in the channels tends to decrease as the flow velocity increases, and the water level in the absorption well with a larger flow rate is maintained lower than that in the absorption well with a smaller flow rate.

Study on Surface Vortices in Pump Sump

  • Long, Ngo Ich;Shin, Byeong Rog;Doh, Deog-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.60-66
    • /
    • 2012
  • One of commonly physical phenomena encountered in pump sump systems in which its significant influence to the hydraulic performance of pump system plays an important role in the field of fluid engineering, is the appearance of free surface and submerged vortices. In this paper, a study of the vortices behavior and their formative mechanism of asymmetry is considered in this paper by using numerical approach. The Reynolds-Averaged Navier-Stokes (RANS) equations and k-omega Shear Stress Transport turbulence model used to describe the properties of turbulent flows, in company with VOF multiphase model, are implemented by Fluent code with multi-block structured grid system. In the numerical simulation, the calculated elevation of air-water interface and vortex core contours are used to classify visually surface vortices as well as submerged vortices. It is shown that the free surface vortex is identified by the concavity of liquid region from the free surface and swirling flow at that own plane. To investigate the distinctive behavior of these vortices corresponding to each given flow rate at the same water level, some numerical testing of them are considered here in such a manner that the flow pattern of surface vortex are obtained similarly to the obtained results from experiment. Furthermore, the influence due to the change of grid refinement and the variation of depth of the concavity are also considered in this paper. From that, these influential factors will be implemented to design a good pump sump with higher performance in the future.

Visualization of Air Absorption Induced by Free Surface Vortex in the Pump Sump Using Multi-phase Flow Simulation (펌프 섬프장내 자유표면 보텍스에 의한 공기흡입 현상의 가시화)

  • Park, Young-Kyu;Li, Kui. Ming.;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.3
    • /
    • pp.59-64
    • /
    • 2011
  • In this study the change of free surface vortex is expressed through the time volume fraction using multiphase unsteady condition in sump, because in previous studies of the pump sump did not represent the behavior of the free surface vortex exactly due to the reason it was calculated using single phase and steady condition. The reliability of the computational analysis is verified through comparing experimental results with that of present numerical analysis. Homogeneous free surface model is used to apply interactions of air and water. The results show that the free surface vortex can be identified on the isotropic surface at air volume fraction 1%~5%. The vortices make an air column from the free surface to the sump intake and are created and destroyed repeatedly. The behavior of free surface vortex at numerical analysis is quite similar to experimental test. The result of vortex motion according to time, works on a cycle.

Design of a 10Gbps CMOS Clock and Data Recovery Circuit (10Gbps CMOS 클럭/데이터 복원 회로 설계)

  • Cha, Chung-Hyeon;Sim, Sang-Mi;Park, Jong-Tae;Yu, Chong-Gun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.459-460
    • /
    • 2008
  • In this paper, a 10Gbps clock and data recovery circuit is designed in $0.18{\mu}m$ CMOS technology. The circuit incorporates a multiphase LC oscillator, a quarter-rate Bang-Bang phase detector, a charge pump and a second order loop filter. The simulation results show that the designed circuit has a peak-to-peak clock jitter of 4.2ps and a peak-to-peak recovered data jitter of 8ps while consuming about 80mW from a 1.8V supply.

  • PDF

Design of a 10Gbps CMOS Clock and Data Recovery Circuit (10Gbps CMOS 클록/데이터 복원회로 설계)

  • Cha, C.H.;Shim, H.C.;Jeon, S.H.;Yu, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.197-198
    • /
    • 2007
  • In this paper, a 10Gbps Clock and Data Recovery circuit is designed in $0.18{\mu}m$ CMOS Technology. The circuit incorporates a multiphase LC oscillator, a quarter-rate Bang-Bang phase detector, a Charge Pump and a second order loop filter. The simulation results show that the designed circuit has a peak-to-peak clock jitter of 4.1ps and a peak-to-peak recovered data jitter of 8ps while consuming about 44mW from a 1.8V supply.

  • PDF