• 제목/요약/키워드: Multi-stress

검색결과 1,231건 처리시간 0.026초

다물체 동역학 시뮬레이션 기반 4단 배수 타워의 동적 특성 연구 (Study on Dynamic Characteristics of 4-Step Drainage Tower Based on Multi-body Dynamics Simulation)

  • 박승운;한영환;전호영;이철희
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권4호
    • /
    • pp.9-16
    • /
    • 2023
  • This paper analyzed a drainage tower used to drain water in flooded areas. Multi-body dynamics simulation was used to analyze the dynamic behavior of the drainage tower. Structural analysis, flexible-body dynamic analysis, and rigid body dynamic analysis were done to study the maximum Von-Mises stress of the drainage tower. The results showed that the maximum Von-Mises stress occurs at the turn table, and it decreases when the angle of the boom is increased. Also, the rate of the change of angle affects the maximum stress so that the maximum stress changes more when the angular velocity of the boom increases. Based on the rigid body dynamic analysis and the theoretical analysis results, the centrifugal force from the angular velocity makes the difference in the maximum stress at the turn table because of the difference in their direction. Consequently, it was concluded that the centrifugal force should be considered when designing construction machinerythat can rotate.

A Flexible Multi-body Dynamic Model for Analyzing the Hysteretic Characteristics and the Dynamic Stress of a Taper Leaf Spring

  • Moon Il-Dong;Yoon Ho-Sang;Oh Chae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1638-1645
    • /
    • 2006
  • This paper proposes a modeling technique which is able to not only reliably and easily represent the hysteretic characteristics but also analyze the dynamic stress of a taper leaf spring. The flexible multi-body dynamic model of the taper leaf spring is developed by interfacing the finite element model and computation model of the taper leaf spring. Rigid dummy parts are attached at the places where a finite element leaf model is in contact with an adjacent one in order to apply contact model. Friction is defined in the contact model to represent the hysteretic phenomenon of the taper leaf spring. The test of the taper leaf spring is conducted for the validation of the reliability of the flexible multi-body dynamic model of the taper leaf spring developed in this paper. The test is started at an unloaded state with the excitation amplitude of $1{\sim}2mm/sec$ and frequency of 132 mm. First, the simulation is conducted with the same condition as the test. Then, the simulations are conducted with various amplitudes in a loaded state. The hysteretic diagram from the test is compared with the ones from the simulation for the validation of the reliability of the model. The dynamic stress analysis of the taper leaf spring is also conducted with the developed flexible multi-body dynamic model under a dynamic loading condition.

용접상세의 변화에 따른 용접이음부의 잔류응력에 관한 연구 (A Study on the Residual Stress in the Welded Joints with Different Details)

  • 임청권;박문호
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.709-720
    • /
    • 1998
  • 용접잔류응력의 모재두께방향을 포함하는 3차원 분포를 파악하기 위해, 용접상세를 변화시킨 필렛용접이음을 대상으로 해서 실험 및 해석을 수행하였다. 특히, 지금까지 계측이 곤란했던 필렛용접이음의 용접루트부의 잔류응력을 실측하였다. 파라메타로써는 용접입열량과 용접층수를 취급하고, 모재두께방향을 포함하는 3차원 잔류응력의 분포를 조사하였다. 그 결과, 입열량이 증가하면, 용접토우와 루트부를 포함하는 용접부에서는 잔류응력의 크기에 변화가 거의 없지만, 인장잔류응력의 영역이 크게 나타났다. 또 단층과 다층용접의 비교에서는, 다층용접 쪽이 단층용접보다 잔류응력이 상당히 낮음을 알 수 있었다. 용접부 근방의 인장잔류응력의 영역도 다층용접 쪽이 단층용접보다 작게 나타난 것을 알 수 있었다.

  • PDF

다단 변속기의 강도설계 검증 (Strength Design Evaluation of the Multi-range Transmission)

  • 공민규;송철기;김영덕
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.12-17
    • /
    • 2011
  • Gears are useful for power transmission due to excellent power transmission performance, low cost, and compactness. In addition, gears have constant speed ratio, compact structure, and excellent efficiency. In order to transmit higher power, the new multi-range transmission requires gears which have greater strength than the existing transmission. This study evaluates stability and durability through gear analysis of the multi-range transmission in commercial vehicles using ROMAX-DESIGNER program. Also, strength design evaluation is carried out by the analysis results which are compared with gear strength theory of AGMA standard. Bending stress and contact stress on gears are lower than their allowable stresses. Therefore, we can evaluate the safety of the gear strength design in multi-range transmission.

다단계 부분구조법을 이용한 코일스프링의 유한요소 응력해석 II : 검증 및 해석 (Finite Element Stress Analysis of Coil Springs using a Multi-level Substructuring Method II : Validation and Analysis)

  • 김진영;허훈
    • 한국자동차공학회논문집
    • /
    • 제8권3호
    • /
    • pp.151-162
    • /
    • 2000
  • This study is concerned with computerized multi-level substructuring methods and stress analysis of coil springs. The purpose of substructuring methods is to reduce computing time and capacity of computer memory by multiple level reduction of the degrees of freedom in large size problems that are modeled by three dimensional continuum finite elements. In this paper, the spring super element developed is investigated with tension, torsion, and bending of a cylindrical bar in order to verify its accuracy and efficiency for the multi-level substructuring method. And then the algorithm is applied to finite element analysis of coil springs. The result demonstrates the validity of the multi-level substructuring method and the efficiency in computing time and memory by providing good computational results in coil spring analysis.

  • PDF

A general tangent operator applied to concrete using a multi-surface plasticity model

  • Silva, Ana Beatriz C.G.;Telles, Jose Claudio F.;Fairbairn, Eduardo M.R.;Ribeiro, Fernando Luiz B.
    • Computers and Concrete
    • /
    • 제16권2호
    • /
    • pp.329-342
    • /
    • 2015
  • The present paper aims at developing a method to accommodate multi-surface concrete plasticity from the point of view of a consistency concept applied to general tangent operators. The idea is based on a Taylor series expansion of the actual effective stress at the stress point corresponding to the previous accumulated true stresses plus the current increment values, initially taken to be elastic. The proposed algorithm can be generalized for any multi-surface criteria combination and has been tested here for typical cement-based materials. A few examples of application are presented to demonstrate the effectiveness of the multi-surface technique as used to a combination of Rankine and Drucker-Prager yield criteria.

셰일저류층의 다단계 수압파쇄에서 응력그림자 효과를 고려한 균열형태 분석 (Analysis of Hydraulic Fracture Geometry by Considering Stress Shadow Effect during Multi-stage Hydraulic Fracturing in Shale Formation)

  • 유정민;박혜민;왕지훈;성원모
    • 한국가스학회지
    • /
    • 제25권1호
    • /
    • pp.20-29
    • /
    • 2021
  • 투과성이 낮은 셰일층에서의 다단계 수압파쇄 시, 파쇄단계 간의 서로 근접한 균열로 인해 지층 간 응력간섭이 발생하는 '응력그림자효과'가 나타날 수 있다. 이로 인해 균열의 전파 방향성이 변화하거나 비정형적인 형태의 균열이 발생하게 된다. 본 연구에서는 응력그림자효과의 영향에 따른 수압파쇄 균열형태와 생산성을 분석하고자 상용 수압파쇄 시뮬레이터 full-3D모델인 'GOHFER'를 사용하였다. 균질한 저류층 모델에서 응력그림자효과 고려 유무에 따른 분석을 수행하였다. 또한 지력학적 물성이 다른 두 셰일층에서 수압파쇄 모델링을 수행하여 영률과 포아송비에 따른 응력그림자효과를 분석하였다. 선행 파쇄단계의 균열로 인한 응력변화는 최대/최소 주응력을 역전시켜 T-방향보다는 생산성이 미비한 L-방향 균열이 주로 형성되었다. 또한 Marcellus 셰일의 경우 연성 특성을 갖는 Eagle Ford 셰일에 비해 높은 취성으로 인해 균열의 폭이 더 두껍게 형성되어 균열 체적이 더욱 크게 산출되었다. Marcellus 셰일지층의 영률이 Eagle Ford 셰일에 비해 크게 낮기 때문에 stage 2에서 응력그림자효과의 영향을 적게 받는 것을 확인할 수 있었다. 이처럼 응력그림자효과는 균열 간의 간격 뿐만 아니라 지력학적 물성에 따라서도 크게 달라진다. 그러므로 좀 더 정확한 균열 형태와 현실성 있는 생산성 예측하기 위해 응력그림자효과는 고려되어야 한다.

열응력과 잔류응력하의 다층박막의 피로수명 해석 (Fatigue Life Analysis on Multi-Stacked Film Under Thermal and Residual Stresses)

  • 박준협
    • 대한기계학회논문집A
    • /
    • 제29권4호
    • /
    • pp.526-533
    • /
    • 2005
  • Reliability problem in inkjet printhead, one of MEMS devices, is also very important. To eject an ink drop, the temperature of heater must be high so that ink contacting with surface reaches above $280^{o}C$ on the instant. Its heater is embedded in the thin multi-layer in which several materials are deposited. MEMS processes are the main sources of residual stresses development. Residual stress is one of the factors reducing the reliability of MEMS devices. We measured residual stresses of single layers that consist of multilayer. FE analysis is performed using design of experiment(DOE). Transient analysis for heat transfer is performed to get a temperature distribution. And then static analysis is performed with the temperature distribution obtained by heat transfer analysis and the measured residual stresses to get a stress distribution in the structure. Although the residual stress is bigger than thermal stress, thermal stress is more influential on fatigue life.

원자로 압력용기 원주방향 용접부의 잔류응력 해석 (Analysis of Residual Stress on Circumferential Weldment of Reactor Pressure Vessel)

  • 김종성;진태은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.430-434
    • /
    • 2001
  • To perform the integrity evaluation of RPV more realistically, it is necessary to evaluate the metallurgical microstructure and residual stress considering more real phenomena such as multi-pass welding process and PWHT. Accordingly, firstly, this paper proposes the integrated assessment methodology systematically developed for residual stress on weldment of RPV by using thermodynamics, diffusion theory, finite element method and validation experiment. Also, the residual stress on circumferential weldment of reactor pressure vessel is calculated considering multi-pass welding process by the commercial finite element package, ABAQUS.

  • PDF

고정자권선의 절연열화 특성분석 (Analysis of the Insulation aging for the stator winding)

  • 오봉근;최교남;한창동;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF