• 제목/요약/키워드: Multi-room

검색결과 488건 처리시간 0.025초

모자동실 개념을 중심으로 한 산과 병동의 건축계획에 관한 연구 (A Study on the Architectural Planning of a Maternity Ward Focused on Rooming-in System)

  • 김언화;유영민
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제8권2호
    • /
    • pp.25-33
    • /
    • 2002
  • The effects and necessity of the breast milk are well known, but the breast-feeding rate in our country is very low. One of the reason is due to the separation policy of mother and baby after delivery. The mother is in the inpatient-room and the baby is in the new-born baby room. This isolation operation of hospital get increased according to the decreasing ratio of breast feeding in Korea. Only a few hospital operates and provides the space for a new-born baby in the mother's room. The system of baby and mother in one room is adopted and operated due to the breast feeding campaign. It is very encouraging, but the space for the baby and the mother is not enough in multi-bed rooms. We should reconsider the relationship between the new-born baby unit and the obstetric ward, and design the patient's room for the baby and the mother.

  • PDF

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

종합병원 병실 내 시환경 조성을 위한 광선반 길이 및 Slat각 제어에 따른 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (Study on Daylight Inflow Environment Consequent on the Length of Light Shelf and Slat Angle Control for Fostering Visual Environment in Patient Rooms of Hospital - By Dynamic Daylight Simulation Using Weather Data -)

  • 조주영;이기호;이효원
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.113-121
    • /
    • 2012
  • A hospital is the most important infra-facility of the places which take care of people's body in social environment. There exist several environmental factors in the ways to heal the human body in hospital ward, but this study tried to look into the improvable pleasant sickroom environment with focus on light environment among the factors. In other words, this study aims at the research on proper daylight inflow into sickroom space as basic data for understanding the link between healing environment and natural lighting. In the simulation analysis through this research, this study completed the initial simulation using Autodesk Revit 2011 with focus on two types of individual multi-bed room units of the two general hospitals located in Gwangju City. This study made a simulation analysis of The two multi-bed rooms looking to the west using the weather data on Gwangju district, which is the strong point of ECOTECT2011. Conclusively, looking into the analysis of the simulation model in time of attaching the length of in & outside light shelf, the angle controlling of light shelf, the daylight factor and DA were found to show the tendency to decrease in the numerical value due to the decrease in sunlight inflow as the simulation model moved more toward the room from the window in comparison with the existing analysis of multi-bed rooms. Particularly, this study was able to read that the daylight factor and DA were more decreasing to improve at the light shelf than the existing bedrooms; conclusively, this study judges that the natural lighting simulation analysis could be helpful in improving the healing environment as basic data.

급기가압 조건에서 복합 구획 공간 화재의 연기 거동에 대한 수치해석 연구 (Numerical Simulation on Smoke Movement in Multi-Compartment Enclosure Fires under Pressurized Air Supply Conditions)

  • 고권현
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.15-21
    • /
    • 2018
  • 본 연구에서는 급기가압 조건에서 거실, 부속실 및 계단실로 구성된 복합 구획 공간에 대해 화재해석을 수행하고 가압 및 환기 조건에 따른 화재 연기의 유동 특성을 분석하였다. 화재 해석은 유효누설면적을 측정하기 위해 제작된 누기율 시험설비에 대하여 수행하였으며, 화재의 거시적 특성과 각 구획에 대한 유동 및 압력 특성의 분석을 통해 급기가압 조건에서의 화염 및 연기 거동에 대한 이해를 증진시키고자 하였다. 화재 해석 결과는 화재 발열량의 크기가 환기 시스템에 의해 공급되는 공기량에 의해서 민감하게 영향을 받게 됨을 보여주었다. 거실과 부속실에서의 속도분포 분석 결과를 통해 급기가압의 조건에서도 화재 연기가 문의 상층부를 통해 부속실로 유출될 수 있음을 확인하였다. 이를 통하여 급기가압 제연시스템의 설계와 적용에 있어서 화재 크기와 공간적 특성과 같은 요인을 고려하는 것이 매우 중요하다는 것을 확인할 수 있었다.

Performance of a 2 Room Multi-Heat Pump with a Constant Speed Compressor

  • Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.184-191
    • /
    • 2004
  • In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.

수요계층별 특성에 맞는 원룸주택 계획지침에 관한 연구 - 서울시 강남 및 신촌지역을 중심으로 - (A Study of planning guide on the one-room housing by user characteristics - Focused on Kangnam & Sinchon area, Seoul -)

  • 최은실;최상헌
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.29-34
    • /
    • 2001
  • The purpose of this study is to provide a practical planning guide for the actual conditions and the preference by user characteristics in one-room housing. The data collected through questionnaire surveys from the residents of one-room housing in kangnam & sinchon. 259 samples we collected and are analyzed by using SPSS-PC. The results are follows : 1) Students: Students prefer monthly rent, down town, of officetel type, 8-l0py room size, and semi-furnished 2)Business men: They prefer multi function housing mixed office and residence, down town, officetel type, 11-l5py, and fully furnished housing. 3)Newly marriged couples: Ordinary habitation site, apt type, 16-l8py ,and 5: 5 division of space(bedroom:others) 4) Old age: normal habitation site, residence-commerce complex building type, middle corridor type, and 11-l5py. 5)Couple+child: lease of deposit basis, apt complex site, and 16-l8py.

  • PDF

학교 교실의 용도별 색채분포 및 색채계획에 관한 연구 (A Study on The Color Examination and Color Planning in the Different Type of Classroom)

  • 김은정;김기환
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.65-68
    • /
    • 2003
  • The purpose of this study is examine the color planning in the different type of classroom to establish interior color planning. This study also uses environmental planning and practical use of basic data for color planning to future school facilities. The summary of this study is as followed. The primary school and middle school classrooms as well as the open space classrooms floor color recommended of brown and the primary school wall color is light yellow, middle school wall color is light yellow and brown. The high school classroom color is recommended brown and wall color to light yellow and green system. The recommended floor color of primary school which includes in computer room and language study room, library of the multi-purpose of media room recommended are gray, brown and pink. The recommended wall color in primary school is light gray. The middle school floor color propose gray and light brown and wall recommended color is light brown, gray, ivory with the high school the computer room, language study room and library. The floor color is recommended gray, green and the wall propose blue. Moreover, recognize that importance of color effectiveness in school interior facilities considering with Interior covering material in class room.

  • PDF

초등학교 병설유치원의 사용실태에 관한 조사연구 (A study on the Planning of the Kindergarten attached to the Elementary School)

  • 강만호;정주성;주석중
    • 교육시설
    • /
    • 제11권1호
    • /
    • pp.39-46
    • /
    • 2004
  • The objective of this study is to propose the architectural basic data for the planning of kindergarten attached to the elementary school. For this study, we selected and investigated 23kindergartens in Gwangju city. The results of this study are as follows. 1) The elementary school in separated style had the advantage of securing educational space and reducing interference with students of elementary school. But it had the problem in using the facilities of elementary school. So we have to consider the kindergarten to be located near by dinning room, multi-purpose hall. 2) Concentrating the entrance, it makes the inside and outside space use easily. For the actual use, we have to establish facilities for convenience in outer-space. 3) For each room, we suggest guides as follow. The classroom and the playroom have to be combined for flexibility and supervision. In the planning of toilet, it must have sliding door for confirm the inside situation and reasonable height partition to consider the student's body-size. The shape of teacher's room must be open-type for supervising children but protect the entry of children. There is consideration for the material room and the sleeping room for all-day-long class.

Some characteristics of an interior explosion within a room without venting

  • Feldgun, V.R.;Karinski, Y.S.;Yankelevsky, D.Z.
    • Structural Engineering and Mechanics
    • /
    • 제38권5호
    • /
    • pp.633-649
    • /
    • 2011
  • The paper presents a study aimed at understanding some characteristics of an interior explosion within a room with limited or no venting. The explosion may occur in ammunition storage or result from a terrorist action or from a warhead that had penetrated into this room. The study includes numerical simulations of the problem and analytical derivations. Different types of analysis (1-D, 2-D and 3-D analysis) were performed for a room with rigid walls and the results were analyzed. For the 3D problem the effect of the charge size and its location within the room was investigated and a new insight regarding the pressure distribution on the interior wall as function of these parameters has been gained. The numerical analyses were carried out using the Eulerian multi-material approach. Further, an approximate analytical formula to predict the residual internal pressure was developed. The formula is based on the conservation law of total energy and its implementation yields very good agreement with the results obtained numerically using the complete statement of the problem for a wide range of explosive weights and room sizes that is expressed through a non-dimensional parameter. This new formula is superior to existing literature recommendations and compares considerably better with the above numerical results.

대시 패널의 투과손실 측정 및 예측 (The Measurement and Prediction of Transmission loss through Dash Panel)

  • 김정수;강연준;김윤재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.122-125
    • /
    • 2005
  • This study is an measurement and prediction of transmission loss through dash panel with multi-path in a vehicle. Measurement results of transmission loss are derided by sound power measured using the sound intensity method under locating a sound source in the anechoic room and reverberant room, respectively. Prediction one is decided by multi-path analysis of dash panel composed by a various part of materials and complicated shape. Finally, two results show a great agreement between measured and predicted transmission loss.

  • PDF