• Title/Summary/Keyword: Multi-mode control

Search Result 353, Processing Time 0.031 seconds

Effect of an aluminum chloride hemostatic agent on the dentin shear bond strength of a universal adhesive

  • Sujin Kim;Yoorina Choi;Sujung Park
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.14.1-14.11
    • /
    • 2023
  • Objectives: This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin. Materials and Methods: Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (n = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's t-test, and the Tukey honestly significant difference test (p = 0.05). Results: No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (p < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (p < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling. Conclusions: When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.

A Study on the Variable Structure Adaptive Control Systems for a Nuclear Reactor (가변구조 적응제어이론에 의한 원자로부하추종 출력제어에 관한 연구)

  • Sung Ha Kwon;Hee Young Chun;Hyun Kook Shin
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.247-255
    • /
    • 1985
  • This paper describes a new method for the design of variable structure model-following control systems(VSMFC). This design concept is developed using the theory of variable structure systems (VSS) and slide mode. The new results are presented on the sliding control methodology to achieve accurate tracking for a class of nonlinear, multi-input multi-output(MIMO), time varying systems in the presence of parameter variations. The design requires little computational effort. The dynamic response is insensitive to parameter variations. The feasibility and the advantages of the method are illustrated by applying it to a 1000 MWe boiling water reactor(BWR). The control is studied in the range of 85%∼90% of rated power for load-following control. A set of 12 nonlinear differential equations is used to simulate the total plant. A 6-th order linear model has been developed from these equations at 85% of rated power. The obtained controller is shown by simulations to be able to compensate for a plant parameter variation over a wide power range.

  • PDF

Fuzzy Control of Smart TMD using Multi-Objective Genetic Algorithm (다목적 유전자알고리즘을 이용한 스마트 TMD의 퍼지제어)

  • Kang, Joo-Won;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.69-78
    • /
    • 2011
  • In this study, an optimization method using multi-objective genetic algorithm(MOGA) has been proposed to develop a fuzzy control algorithm that can effectively control a smart tuned mass damper(TMD). A 76-story benchmark building subjected to wind load was selected as an example structure. The smart TMD consists of 100kN MR damper and the natural period of the smart TMD was tuned to the first mode natural period of the example structure. Damping force of MR damper is controlled to reduce the wind-induced responses of the example structure by a fuzzy logic controller. Two input variables of the fuzzy logic controller are the acceleration of 75th floor and the displacement of the smart TMD and the output variable is the command voltage sent to MR damper. Multi-objective genetic algorithm(NSGA-II) was used for optimization of the fuzzy logic controller and the acceleration of 75th story and the displacement of the smart TMD were used as objective function. After optimization, a series of fuzzy logic controllers which could appropriately reduce both wind responses of the building and smart TMD were obtained. Based on numerical results, it has been shown that the control performance of the smart TMD is much better than that of the passive TMD and it is even better than that of the sample active TMD in some cases.

The optimum design of MQW Buried-RWG LD (MQW Buried RWG LD 최적화 설계)

  • 황상구;오수환;김정호;김운섭;김동욱;하홍춘;홍창희
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.312-319
    • /
    • 2001
  • We proposed a B-RWG LD (Buried-ridge waveguide laser diode) having more merits than a conventional RWG-LD. It's ridge width is controlled easily, it has the advantage of being more planar than the RWG-LD and it is possible to control refractive index with growth layer thickness. Before fabricating the device, we designed the optimal device for single mode, high efficiency and high power operation. From theoretical analysis, we have to control the $d_2, d_3$ layer thicknesses for lateral effective index difference, $\Delta_{nL}$ to be higher than critical value, and simultaneously consider the ridge width for single mode and low threshold current operation. As a result, it is possible to make a single mode LD having the ridge width of $6~9{\mu}m$ if the lateral effective index difference was controlled properly. perly.

  • PDF

Flow-Based Admission Control Algorithm in the DiffServ-Aware ATM-Based MPLS Network

  • Lee, Gyu-Myoung;Choi, Jun-Kyun;Choi, Mun-Kee;Lee, Man-Seop;Jong, Sang-Gug
    • ETRI Journal
    • /
    • v.24 no.1
    • /
    • pp.43-55
    • /
    • 2002
  • This paper proposes a flow-based admission control algorithm through an Asynchronous Transfer Mode (ATM) based Multi-Protocol Label Switching (MPLS) network for multiple service class environments of Integrated Service (IntServ) and Differentiated Service (DiffServ). We propose the Integrated Packet Scheduler to accommodate IntServ and Best Effort traffic through the DiffServ-aware MPLS core network. The numerical results of the proposed algorithm achieve reliable delay-bounded Quality of Service (QoS) performance and reduce the blocking probability of high priority service in the DiffServ model. We show the performance behaviors of IntServ traffic negotiated by end users when their packets are delivered through the DiffServ-aware MPLS core network. We also show that ATM shortcut connections are well tuned with guaranteed QoS service. We validate the proposed method by numerical analysis of its performance in such areas as throughput, end-to-end delay and path utilization.

  • PDF

Design, Implementation, and Validation of KOMPSAT-2 Software Simulator

  • Lee, Sang-Uk;Lee, Byoung-Sun;Kim, Jae-Hoon;Cho, Sung-Ki
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.140-152
    • /
    • 2005
  • In this paper, we present design features, implementation, and validation of a satellite simulator subsystem for the Korea Multi-Purpose Satellite-2 (KOMPSAT-2). The satellite simulator subsystem is implemented on a personal computer to minimize costs and trouble on embedding onboard flight software into the simulator. An object-oriented design methodology is employed to maximize software reusability. Also, instead of a high-cost commercial database, XML is used for the manipulation of spacecraft characteristics data, telecommand, telemetry, and simulation data. The KOMPSAT-2 satellite simulator subsystem is validated by various simulations for autonomous onboard launch and early orbit phase operations, anomaly operation, and science fine mode operation. It is also officially verified by successfully passing various tests such as the satellite simulator subsystem test, mission control element system integration test, interface test, site installation test, and acceptance test.

  • PDF

Advanced PEEP Controlled system development (최신PEEP제어 시스템 개발)

  • Kim, Jong-Cheol;Lee, Sang-Hag;Joo, Jung-Kyou
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.137-140
    • /
    • 2008
  • The purpose of PEEP is to increased effect reparation in lung. Recently trend of technology is possible to have multi-level or to control freely for variety breathing pattern or breathing mode. Those new technology need some issue like electronic controlled actuator(solenoid), PEEP valve of special structure and control software in micro controller. This paper brief to develop actuator(solenoid) and PEEP valve. This development is to make commercial product of MEKICS.Co.LTD Electronic controlled actuator(Solenoid) is to make force depend on current in linear. And force is convert to pressure in PEEP valve. Major technical issue are how to make the valve with continuous force even dough moving and how to optimize to convert force - pressure.

  • PDF

Low-earth orbiting satellite multi-output converter design and verification by using EDF modeling (EDF 모델링을 이용한 저궤도위성 다중 출력 컨버터 설계 및 검증)

  • Yun, SeokTeak;Yang, JeongHwan
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.2
    • /
    • pp.76-79
    • /
    • 2012
  • Satellite power system is critical for mission design and survival operation. Accordingly power conversion circuit has to stable design and verify for operation condition change (load, voltage, thermal condition). however, multi-stage make complicate for modeling and get all state solution. In this paper present all state solution for multi-stage converter by using Extended Describing Function(EDF) modelling. EDF modelling has merit to solve complex circuit but it has limit too. Because of fundamental approximation, EDF modeling is not match all topology. Consequently, we verify passible topology for EDF modeling and stable design multi-stage converter.

A Study on the Optimization of the Transmission Method for COMS Satellite Control Signal (통신해양기상위성의 위성 관제 신호 전송 방식의 최적화 연구)

  • Kim, Yeong-Wan;Yang, U-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.11
    • /
    • pp.47-53
    • /
    • 2006
  • The power losses due to modulation index for multi-modulation scheme were analyzed under various transmission mode of satellite control and the necessary satellite link margin for transmission mode were proposed in this paper On the basis of the analyses for interference between the transmission signals and threshold of satellite control signal receiver, the optimal subcarrier signals were proposed for satellite range measurement methods, respectively. The subcarrier signal of 12 kHz or 14 kHz is proper for telecommand using the ESA method, and 16 kHz for telecommand signal using the GSTDN method. On the other hand, the telemetry subcarrier of 65.536 kHz is a proper in the viewpoint of receiver threshold value.

The Analysis of Vibration Due to Magnetic Exciting Force in the Brushless DC Motor (다기 전력 시스템 동적 안정도 향상을 위한 분산 제어 기반 PSS 및 TCSC 제어기 설계)

  • Lee, Seung-Cheol;Seo, Jang-Cheol;Moon, Seung-Ill;Park, Jong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.13-19
    • /
    • 2001
  • This paper deals with decentralized control scheme and its application to multi-machine power systems. Decentralized control scheme has several practical advantages, because power system has geographically distributed characteristics. In this paper, decentralized observer-based optimal Power System Stabilizer(PSS) and Thyristor-Controlled Series Capacitor(TCST) controller are designed and tested in WSCC 9 bus system with one TCSC installed. Simulation results show that the proposed decentralized controller has satisfactory performances comparable to the centralized controller. In addition, using modal analysis, this paper shows that the proposed decentralized controller significantly affects only one pair of eigenvalues which have high participation with each generator, while slightly affects other eigenvalues. This result indicates that the application of the decentralized control scheme to enhance power system dynamic stability via excitation control have potential advantages because each low-damped mode occurs dominantly by each decentralized subsystem.

  • PDF