• Title/Summary/Keyword: Multi-detector

Search Result 515, Processing Time 0.029 seconds

Detection of Buried Objects and Imaging of Subsurface Resistivity Structure using Loop-Loop EM Methods (소형루프 전자탐사법을 이용한 매설물 탐지 및 지하 전기비저항 영상화)

  • Seol Soon Jee;Song Yoonho;Cho Seong-Jun;Son Jeong-Sul;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.309-315
    • /
    • 2002
  • Conventional electromagnetic (EM) method using small loops as a source and receiver has been used in detection of conductive buried objects like a metal detector or in qualitative estimation of the subsurface conductivity variation. Recently, however, since detection of buried objects and imaging of the subsurface conductivity distribution in a relatively conductive area are in a high demand for environmental and engineering purposes, the quantitative interpretation technique of EM data is actively studied. In this regard, we introduce a brief principle of EM survey and show an example of the detection of buried conductive material and imaging of the subsurface conductivity distribution based on data measured at a test survey area. Through this study, we show that multi-frequency EM surveys using small loops may be a good solution to give quick and detail information of subsurface in a conductive survey area.

Opening New Horizons with the L4 Mission: Vision and Plan

  • Kyung-Suk Cho;Junga Hwang;Jeong-Yeol Han;Seong-Hwan Choi;Sung-Hong Park;Eun-Kyung Lim;Rok-Soon Kim;Jungjoon Seough;Jong-Dae Sohn;Donguk Song;Jae-Young Kwak;Yukinaga Miyashita;Ji-Hye Baek;Jaejin Lee;Jinsung Lee;Kwangsun Ryu;Jongho Seon;Ho Jin;Sung-Jun Ye;Yong-Jae, Moon;Dae-Young Lee;Peter H. Yoon;Thiem Hoang;Veerle Sterken;Bhuwan Joshi;Chang-Han Lee;Jongjin Jang;Jae-Hwee Doh;Hwayeong Kim;Hyeon-Jeong Park;Natchimuthuk Gopalswamy;Talaat Elsayed;John Lee
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.263-275
    • /
    • 2023
  • The Sun-Earth Lagrange point L4 is considered as one of the unique places where the solar activity and heliospheric environment can be observed in a continuous and comprehensive manner. The L4 mission affords a clear and wide-angle view of the Sun-Earth line for the study of the Sun-Earth and Sun-Moon connections from he perspective of remote-sensing observations. In-situ measurements of the solar radiation, solar wind, and heliospheric magnetic field are critical components necessary for monitoring and forecasting the radiation environment as it relates to the issue of safe human exploration of the Moon and Mars. A dust detector on the ram side of the spacecraft allows for an unprecedented detection of local dust and its interactions with the heliosphere. The purpose of the present paper is to emphasize the importance of L4 observations as well as to outline a strategy for the planned L4 mission with remote and in-situ payloads onboard a Korean spacecraft. It is expected that the Korean L4 mission can significantly contribute to improving the space weather forecasting capability by enhancing the understanding of heliosphere through comprehensive and coordinated observations of the heliosphere at multi-points with other existing or planned L1 and L5 missions.

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

Analysis of Bone Mellow Density in Adults of Domestic Local Area Using Multi-Detector Computed Tomography: Focus on Corelation About Eating Habits, Lifestyle, Physical Features and Social Characteristics (다중 검출 전산화단층촬영을 이용한 국내 일부 지역 성인의 골밀도 현황 분석: 식습관, 생활습관, 신체적, 사회적 특성과의 상관관계를 중심으로)

  • Lee, Tae Hui;Kim, Tae-Hyung;So, Woon Young;Lim, Hei Gyeom;Lim, Cheong-Hwan;Park, Myeong Hwan;Cheoun, Myung-Ki
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.517-526
    • /
    • 2016
  • This study analyzed the correlation between BMD (bone mineral density) value calculated in the MDCT (multidetector computed tomography) and lifestyle, physical features and social characteristics. From July 15 2015 to June 6 2016, we converted from HU (hounsfield unit) value measured by using MDCT to T-score for BMD of 141 patients (male: 63, female: 78) in W medical center. We measured the 2nd, 3rd and 4th lumbar spine and analyzed the correlation between gender differences in BMD and lifestyle, physical features and social characteristics. Statistical significance was validated using independent sample T test with one way Anova. Gender BMD was confirmed that a statistically significant difference (p<0.05). BMD values decreased with increasing age but for the statistically men, there was no significant difference from 20s to 50s, it only showed a significant difference in 20s and 60s (p<0.001). For the statistically women, there was no significant difference from 20s to 40s. but since 50s BMD was decreased rapidly, which showed a significant difference (p<0.001). women showed significant differences for the menstruation and menopause, childbirth, alcohol, cereals and greasy food in bone mineral density (p<0.05) but there were no significant differences in men. The bone mineral density values calculated by the MDCT and lifestyle, physical features and social characteristics correlation analysis method is considered to be used as a basis for estimating the state in BMD and osteoporosis management.

MICROTENSILE BOND STRENGTH OF ALL-IN-ONE ADHESIVE TO CARIES-AFFECTED DENTIN (우식이환 상아질에 대한 all-in-one adhesive의 미세인장결합강도)

  • Moon, Ji-Deok;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength to caries-affected dentin. Twenty one extracted human molars with occlusal caries extending into mid-dentin were prepared by grinding the occlusal surface flat. The carious lesions were excavated with the aid of caries detector dye. The following adhesives were applied to caries-affected dentin according to manufacturer's directions; $Scotchbond^{TM}$ Multi-Purpose in SM group, Adper Prompt $L-Pop^{TM}$ 1 coat in LP1 group, 2 coats in LP2 group, 3 coats in LP3 group, $Xeno^{(R)}$ III 1 coat in XN1 group, 2 coats in XN2 group. and 3 coats in XN3 group. After application of the adhesives, a cylinder of resin-based composite was built up on the occlusal surface. Each tooth was sectioned vertically to obtain the $1{\times}1\;mm^2$ sticks. The microtensile bond strength was determined. Each specimen was observed under SEM to examine the failure mode. Data were analyzed with one-way ANOVA. The results of this study were as follows; 1. The microtensile bond strength values were; SM ($14.38{\pm}2.01$ MPa), LP1 ($9.15{\pm}1.81$ MPa), LP2(14.08{\pm}1.75$ MPa), LP3 ($14.06{\pm}1.45$ MPa). XN1 (13.65{\pm}1.95$ MPa). XN2 ($13.98{\pm}1.60$) MPa, XN3 ($13.88{\pm}1.66$) MPa, LP1 was significantly lower than the other groups in bond strength (p < 0.05). All groups except LP1 were not significantly different in bond strength (p > 0.05). 2. In LP1, there were a higher number of specimens showing adhesive failure. Most specimens of all groups except LP1 showed mixed failure.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Analytical method of aflatoxins in edible oil and infant-children foods (식용유지와 영유아식품 중 아플라톡신 분석방법)

  • Hu, Soo-Jung;Park, Seung-Young;Kim, Soon-Sun;Lee, Joon-Goo;Song, Ji-Young;Kang, Eun-Gi;Lee, Hyun-Sook;Cho, Dae-Hyun
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.150-157
    • /
    • 2011
  • Aflatoxins are secondary metabolites of the molds of Aspergillus flavus and Aspergillus parasiticus. They are highly carcinogenic compounds and can affect a wide range of vegetable commodities such as cereals (especially corn), nuts, peanuts, fruits and oil seeds, in the field and during storage. In fact, oilseeds are often stored for weeks in conditions that promote the mould growth, and the possible consequent presence of aflatoxins in oilseeds can lead to their transfer in oil. In addition, aflatoxins can be found as a natural contaminant in multi-cereals and beans making baby food for infants and young-children. The objective of this study was to validate the liquid extraction method or develop an analytical method for edible oil and infant-children foods. Therefore, this study developed condition of extract for aflatoxins ($B_1$, $B_2$, $G_1$ and $G_2$) in edible oil using a high performance liquid chromatography with florescence detector (HPLC/FLD). Aflatoxins were extracted from edible oil samples by means of MSPD (Matrix solid phased dispersion), utilizing $C_{18}$ as dispersing material and purified by using immunoaffinity column. The gression line coefficients were above 0.999. The recoveries for aflatoxins ranged from 85.9 to 93.0%, and relative standard deviations were below 5.7%. The new developed method of aflatoxins effectively enhanced recoveries by using MSPD-Immunoaffinity column compared with liquid extraction. The analytical method for liquid extraction of aflatoxin was appropriate for infant-children food. Reviewing the current method, the recoveries of aflatoxins ($B_1$, $B_2$, $G_1$ and $G_2$) were 89.5~92.3%.

Effect of Dietary Supplementation of Garlic and May Flower Powder on CO2 and CH4 Emission by Hanwoo Cow (산사 및 마늘 분말이 한우암소의 이산화탄소 및 메탄 발생량에 미치는 영향)

  • Kim, Du Ri;Ha, Jae Jung;Song, Young Han
    • Journal of Animal Science and Technology
    • /
    • v.54 no.5
    • /
    • pp.363-368
    • /
    • 2012
  • This study was conducted to investigate the effects of dietary garlic and may flower powder on $CO_2$ and $CH_4$ emission by Hanwoo cows fed TMR (Total Mixed Ration) based diet. Animals were housed in a hood-type respiration chamber and the environmental temperature was maintained at $20^{\circ}C$. Gases were measured for 24 hours using the multi-detector instrument gas monitoring system (Mamos-300, Australia). The treatments composed of groups with no intake of garlic and may flower powder (Control), with intake of garlic at 0.5% of DM (T1), with intake of garlic at 1% of DM (T2), with intake of may flower at 0.5% of DM (T3), with intake of may flower at 1% of DM (T4), with intake of garlic and may flower at 0.5% of DM (T5) and with intake of garlic and may flower at 1% of DM (T6). The results indicated that $CO_2$ emission in T3 was 53% lower than that of control (p<0.05), and $CH_4$ emissions was 57% lower than control (p<0.05). Also, the hourly pattern of $CO_2$ and $CH_4$ emissions in T3 showed the least difference with all treatments. Gas emissions pattern peaked after 1 hour of feeding and this gap was wider in the afternoon than in the morning hours.