• Title/Summary/Keyword: Multi-coupled

Search Result 739, Processing Time 0.028 seconds

An FSI Simulation of the Metal Panel Deflection in a Shock Tube Using Illinois Rocstar Simulation Suite (일리노이 록스타 해석환경을 활용한 충격파관 내 금속패널 변형의 유체·구조 연성 해석)

  • Shin, Jung Hun;Sa, Jeong Hwan;Kim, Han Gi;Cho, Keum Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.361-366
    • /
    • 2017
  • As the recent development of computing architecture and application software technology, real world simulation, which is the ultimate destination of computer simulation, is emerging as a practical issue in several research sectors. In this paper, metal plate motion in a square shock tube for small time interval was calculated using a supercomputing-based fluid-structure-combustion multi-physics simulation tool called Illinois Rocstar, developed in a US national R amp; D program at the University of Illinois. Afterwards, the simulation results were compared with those from experiments. The coupled solvers for unsteady compressible fluid dynamics and for structural analysis were based on the finite volume structured grid system and the large deformation linear elastic model, respectively. In addition, a strong correlation between calculation and experiment was shown, probably because of the predictor-corrector time-integration scheme framework. In the future, additional validation studies and code improvements for higher accuracy will be conducted to obtain a reliable open-source software research tool.

Rapid and Precise Determination of Pb Isotope Ratios Using Mu1ti-Collector ICP/MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 신속하고 정밀한 Pb 동위원소 분석)

  • 최만식;정창식;신형선;임태선
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.157-171
    • /
    • 2001
  • This study investigated the effects of Pb/Tl ratio, Pb concentration and concomitant matrix elements on the measurement of Pb isotope ratios using multi-collector ICP/MS (AXIOM MC model). Accuracy and reproducibility of Pb isotope ratios in NBS 981 solution were estimated for 42 data measured from March to August 2001. Pb isotopes measured in rocks, bronzes and sediments were compared to data measured by TIMS. Reproducibilities for $^{206}Pb/^{204}Pb,\; ^{207}Pb/^{204}Pb,\;and\;^{208}Pb/^{204}Pb$ ratio were about 500 ppm (2sd) and for $^{207}Pb/^{206}Pb$\;and\;^{208}Pb/^{206}Pb$ were 100~200 ppm for 200 ng of Pb in NBS 981 solution. The optimum conditions for the analysis of Pb isotope ratios with AXIOM MC for best accuracy and reproducibility were defined as follows; 1) Pb/Tl ratio is about 10 2) Pb concentration is about 100 ng/ml 3) correction for mass discrimination is performed by exponential law using 2.3887 of $^{205}Tl/^{203}Tl$ and Pb mass fractionation factor empirically obtained from $ln(^{208}Pb/^{206}Pb)-ln(^{205}Tl/^{203}Tl)$ relationship. The sample data measured with MC/ICP/MS for acid-digested and chemically separated rock samples, and acid-digested bronze samples and sediment samples coincide with those of TIMS within analytical errors. Therefore, MC/ICP/MS is a rapid analytical technique for Pb isotope ratios with the similar precision compared with TIMS.

  • PDF

The Design and Fabrication of the Triple-Band Planar Monopole Antenna for Coupled U Patch Line and Rectangular Patch (U자형 패치 라인과 사각 패치를 결합한 삼중 대역 평면형 모노폴 안테나 설계 및 제작)

  • Lee, Sung-Hun;Lee, Seung-Woo;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.745-753
    • /
    • 2011
  • In this paper, the planar monopole antenna for multi-band service is proposed. The proposed antenna, which is a rectangular patch antenna with a U-shaped slit based on a monopole antenna for wide bandwidth characteristic, is designed and analyzed. The antenna size has been miniaturized by using the U-shaped slit. The frequency characteristics are modified and optimized by varying specific parameters. To obtain desired frequency bands, the U-shaped slit and patch lines have been applied. Whole antenna dimensions including the ground plane are $35{\times}50{\times}1\;mm^3$, and the antenna part size is $35{\times}27\;mm^2$. It is fabricated on the FR-4 substrate(${\epsilon}_r=4.4$) using a microstrip line of $50{\Omega}$ for impedance matching. For the measured results, the impedance bandwidth below a VSWR of 2 is 790~916 MHz, 1.74~2.14 GHz, and 2.36~3.13 GHz. The fabricated antenna is satisfied with the aimed impedance bandwidth in GSM/DCS/US-PCS/UMTS/Bluetooth/S-DMB applications.

Miniaturized Multilayer Band Pass Chip filter for IMT-2000 (IMT-2000용 초소헝 적층형 대역 통과 칩 필터 설계 및 제작)

  • Lim Hyuk;Ha, Jong-Yoon;Sim, Sung-Hun;Kang, Chong-Yun;Choi, Ji-Won;Choi, Se-Young;Oh, Young-Jei;Kim, Hyun-Jai;Yoon, Seok-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.961-966
    • /
    • 2003
  • A Multi-Layer Ceramic (MLC) chip type Band-Pass Filter (BPF) using BiNb$\_$0.975/Sb$\_$0.025/ $O_4$ LTCC (Low Temperature Co-fired Ceramics) and MLC processing is presented. The MLC chip BPF has the benefits of low cost and small size. The BPF consists of coupled stripline resonators and coupling capacitors. The BPF is designed to have an attenuation pole at below the passband for a receiver band of IMT-2000 handset. The computer-aided design technology is applied for analysis of the BPF frequency characteristics. The attenuation pole depends on the coupling between resonators and the coupling capacitance. An equivalent circuit and structure of MLC chip BPF are proposed. The frequency characteristics of the manufactured BPF is well acceptable for IMT-2000 application.

Spectroelectrochemical Study for Thin Film of Gold Nanoparticles (금 나노입자 박막의 분광전기화학적 연구)

  • Seo, Seong S.;Chambers, James Q.
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.32-36
    • /
    • 2006
  • films of gold nanoparticles were formed on indium tin oxide (ITO) by an electrodeposition method from an aminosilicate stabilized gold colloid solution. The thin films were examined by cyclic voltammetry (CV), scanning electron microscopy (SEM), UV-visible, and energy dispersive X-ray spectroscopy (EDXS). The surface coverage of gold nanoparticles on the thin film was estimated to 1.2 nanomole/cm2. An anthraquinone-2, 6-disulfonic acid, disodium salt (AQDS) self-assembled layer was generated by immersing gold thin film into 1mM of AQDS in 0.1M HClO4 solution for over 20 hours. As a result, a new absorbance peak from the multi-layers (AQDS/thin film of gold /ITO) was obtained about at 690 nm. Also, the surface plasmon absorption of multi-layers was measured by UV-Visible spectrometer along with chronoamperometry by applying the various potentials from +0.5V to -0.5V. The maximum surface plasmon absorption band at 550 nm was decreased by applying negative potentials. The change of absorbance was correlated with the surface coverage of the AQDS indicating the pseudo-capacity surface state of the AQDS layer was coupled to the energy level of the plasmonband by applied negative potentials.

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Application of Monthly Water Balance Models for the Climate Change Impact Assessment (기후변화 영향평가를 위한 월 물수지모형의 적용성 검토)

  • Hwang, Jun-Shik;Jeong, Dae-Il;Lee, Jae-Kyoung;Kim, Young-Oh
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.147-158
    • /
    • 2007
  • This study attempted to determine a suitable hydrologic model for assessing the impact of climate change on water resources, and to assess the accuracy of streamflow scenarios simulated by the selected hydrologic model using the meteorological scenarios of the Seoul National University Regional Climate Model(SNURCM). Comparison of four water balance models and two daily conceptual rainfall-runoff models for the simulation capability of the Daecheong Dam inflow indicated that the abcd model performs the best among the tested water balance models and performs as well as SSARR that is popular as a daily rainfall-runoff model in Korea. Parameters of the abcd model were then estimated for 12 ungauged subbasins of the Geum River by the regionalization method. The model parameters were first calibrated at nine multi-purpose dams and were then regionalized using catchment characteristics for another four multi-purpose dams, which were assumed to be ungauged sites. The model efficiency(ME) coefficients of the simulated inflows for these four dams were at least 87%. The MEs of the hindcasted meteorological rainfall scenarios of the 12 subbasins of the Geum River were more than 60%. Moreover, the ME of the Daecheong Dam inflow simulated by the abcd model using the SNURCM rainfall scenarios was more than 80%. Therefore, this research concluded that the abcd model coupled with the SNU-RCM meteorological scenarios can be used for impact assessment studies of climate change on water resources.

Simulation of Past 6000-Year Climate by Using the Earth System Model of Intermediate Complexity LOVECLIM (중간복잡도 지구시스템모델 LOVECLIM을 이용한 과거 6천년 기후 변화 모의)

  • Jun, Sang-Yoon
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.87-103
    • /
    • 2019
  • This study introduces the overall characteristics of LOVECLIM version 1.3, the earth system model of intermediate complexity (EMIC), including the installation and operation processes by conducting two kinds of past climate simulation. First climate simulation is the equilibrium experiment during the mid-Holocene (6,000 BP), when orbital parameters were different compared to those at present. The overall accuracy of simulated global atmospheric fields by LOVECLIM is relatively lower than that in Coupled Model Intercomparison Project phase 5 (CMIP5) and Paleoclimate modelling Intercomparison Project phase 3 (PMIP3) simulations. However, surface temperature over the globe, the 800 hPa meridional wind over the mid-latitude coastal region, and the 200 hPa zonal wind from LOVECLIM show similar spatial distribution to those multi-model mean of CMIP5/PMIP3 climate models. Second one is the transient climate experiment from mid-Holocene to present. LOVECLIM well captures the major differences in surface temperature between preindustrial and mid-Holocene simulations by CMIP5/PMIP3 multi-model mean, even though it was performed with short integration time (i.e., about four days in a single CPU environment). In this way, although the earth system model of intermediate complexity has a limit due to its relatively low accuracy, it can be a very useful tool in the specific research area such as paleoclimate.

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

Natural isotopes and trace element analyses in glass samples (판유리 시료에서 동위원소 및 미량원소 분석법)

  • Min, Ji-Sook;Heo, Sangcheol;Kim, Jae-Guin;Kim, Eun-Ho;Kim, Dong-Wook;Chung, Hee-Sun
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.219-226
    • /
    • 2007
  • Glass is frequently encountered as types of materials that are submitted to forensic science laboratories as a result of trace evidence transfers. The repeatability and the reproducibility of trace element analysis were presented. An analysis of variance (ANOVA) was performed on laser ablation inductively coupled plasma spectrometric analyses of the fragments to identify the source. Pairwise comparisons were completed for all samples. In a pairwise comparison, each sample was compared to each other for a possible [n(n-1)/2] (n : numbers of the samples) total comparison to associate/discriminate samples using Tukey's HSD method. The aim of this study was to determine the utility of LA-ICP-MS for multi-element analysis of forensic samples. The 12 glass fragments from two manufacturers were collected and analyzed to identify the source. An analysis of variance (ANOVA) was performed on 31 elements in NIST 612 Trace elements in Glass. Elements were classified into four categories defined by the combination of precision and variation of inter-samples. We selected 11 elements, 209Bi, 90Zr, 121Sb, 178Hf, 59Co, 238U, 208Pb, 140Ce, 118Sn, 49Ti and 137Ba. 6 pairs out of 66 possible pairs were not distinguished when compared by 137Ba (p<0.05). However, all samples were distinguished using both 49Ti and 137Ba (p<0.05). In conclusion, multi-elemental analysis with LA-ICP-MS is a potential tecnique for the discrimination of forensic samples.